• Title/Summary/Keyword: Oblique Line

Search Result 100, Processing Time 0.021 seconds

Camera Calibration with Two Calibration Planes and Oblique Coordinate Mapping (두 보정면과 사교좌표 매핑을 이용한 카메라 보정법)

  • Ahn, Jeong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.119-124
    • /
    • 1999
  • A method to find the line of sight ray in space which corresponds to a point in an image plane is presented. The line of sight ray is defined by two points which are the intersections between the two calibration planes and the sight ray. The intersection point is found by the oblique coordinate mapping between the image plane and the calibration plane in the space. The proposed oblique coordinate mapping method has advantages over the transformation matrix method in the required memory space and computation time.

  • PDF

Echelon Feeder of Brown Rice for On-line Inspection Using Image Processing (영상처리식 온라인 품위판정을 위한 현미의 정렬공급장치)

  • Kim, Tae-Min;Noh, Sang-Ha
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.197-205
    • /
    • 2010
  • An automatic echelon feeder of brown rice was presented for quality inspection system using color image processing. A echelon feeder was developed with vibratory feeder and cylindrical indent singulator having oblique light. The vibratory feeder consisted of a hopper, electromagnetic vibrator and multichannel grooves and supply the grain sample to the singulator. The feeding performance such as feed rate, blocking frequency of the channel was dependent on the size of groove and vibration pattern. A cylindrical indent singulator consisted of a rotating cylinder, prisms and a tungsten-halogen light source. It delivered grain kernels under the camera in a echelon form and illuminate the kernels with oblique ray and ambient light. The size of the indents installed on the surface of the rotating cylinder was determined by the dimensions of the paddy and a small triangular prism was placed in each indent to apply $ 20^{\circ}$ oblique light to the grain kernel.

Anterior Screw Fixation of Type II Odontoid Fracture (제 II 형 치상돌기 골절에서 전방경유 나사못 고정술)

  • Kim, Myung-Jin;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Hwang, Sung-Kyu;Hamm, In-Suk;Park, Yeun-Mook;Kim, Seung-Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1461-1468
    • /
    • 2000
  • Objective : The aim of this study is to evaluate clinical outcome of anterior screw fixation for type II odontoid fractures for the prliematim of atlanatoaxial mobility. Methods : Between 1995 and 1999, we treated 15 cases of type II odontoid fractures by anterior screw fixation among 44 cases of odontoid fractures. Thece included 14 males and 1 female aged from 23 to 63 years, with a mean age of 39.7 years. The causes of trauma were traffic accident in 13 cases, slip down in 1 and fall down in 1. The fracture type was type II-P in 7 cases, type II-A in 3, type II-N in 2 and type II-A and P in 3. The fracture line was oblique downward and backward in 6 cases, oblique downward and forward in 3 and horizontally in 6. The range of follow up was 4 to 47 months(mean 26.5 months). Results : Adequate reduction and fixation were obtained in 12 cases. Three cases in which fracture type and line were type II-A and oblique downward forward were failed, so posterior transarticular screw fixation was performed. All except 3 failed cases had adequate cervical movement and stability. There were no operative mortality nor morbidity. Conclusion : Anterior screw fixation provides the best anatomical and functional results for type II odontoid fracture with intact transverse ligament when fracture line is horizontal or oblique downward and backward. But it is limited when fracture line is oblique downward and forward.

  • PDF

A study on the suitable of building size in district units plan (지구단위계획(地區單位計劃)에서 건축(建築) 규모설정(規模設定)에 관한 연구(硏究))

  • Lee, Won-Geun;Lee, Jae-Kook;Do, Gyu-Hwan
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.1
    • /
    • pp.39-49
    • /
    • 2003
  • The height provisions, by the urban planning, describe the hightest height per width division, also define oblique line limitation by road without mentioning the highest per width division. Therefore this study will be a basic model for the standard of measuring the highest height per width division analysizing the propriety of current standard of oblique limitation. This technique is prepared to prevent the confusion and to complements the existing planning method. Therefore, it takes more time to establish this new method and to apply it to the existing condition. This study reviewed density control in District Units Plan, based on the guidelines of density, which included height, ratio of total floor to ground area, and land distribution. This study aims to provide efficient analysis by using current oblique limitation provisions Thus, proving the area rations of general residential areas are decreasing. Since the purpose of the District Units Plan is to avoid confusion and help ease the existing problematic conditions which have risen from the two above-mentioned conventional systems, further observation and research on these areas are necessary.

  • PDF

The Configuration and Location of the Nipple-Areola Complex of Young Korean Adult (젊은 한국인 남성의 유두 유륜 복합체의 모양과 위치)

  • Yoon, Sang Yup;Sim, Hyung Bo
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.706-709
    • /
    • 2005
  • The absence of the nipple-areolar complex(NAC) in men are seldom stated, as a result of trauma, burn, mastectomy, or after the correction of extreme bilateral gynecomastia. A total of 50 healthy men aged 21 to 27 years were examined. We recorded the configuration (dimensions and shape) and the location of the NAC with respect to fixed skeletal anatomic landmarks. Of the 50 subjects examined, 44 had oval and 6 had a round NAC. The mean diameter for a round NAC was 24.3 mm. The center of the NAC was in the fourth intercostal space in 41 volunteers and in the fifth intercostal space in 9 of the subjects. To localize the NAC on the chest wall, at least three reproducible measurements proved to be necessary, composed of a horizontal line(distance from the midsternal line to the nipple, A), a medial oblique line(distance from the sternal notch to the nipple, B) and a lateral oblique line(distance from the acromioclavicular joint to the nipple, C). Using these three parameters, we recommend that the appropriate location can be calculated derived from the circumference of the chest.

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

A study on the visual sensibility of brassiere design(Part II) (브래지어 디자인에 대한 시각적 감성연구(제2보))

  • 하수진;이경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.767-775
    • /
    • 1999
  • The purpose of this study is to investigate the visual sensibilities of brassiere design. Brassieres were divided into three types according to connection of a cup and a strp. In each type Lace was used where the part of the cup divided by Lines which were constructed such as a mold a horizontal a vertical a mixed and an oblique design. As a result 39 brassieres were obtained. The experiment has been done for seven groups which were divided by the type line and lace with 5 semantic differential bi-polar scales and 10 specialists. The data was analyzed using the statistical SPSS package. The major findings of this research were as follows. An oblique design line in the brassiere were effective in making the breast look bigger more buxom and more voluminous. To make the breast look small and unvoluminous the use of a mold in the 1/2 cup brassiere was effective. Also a mold using lace ion the 1/2 cup brassiere had an effect in making the breast look flatter and broader.

  • PDF

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

A Study on the Performance Improvement of Thinning Algorithm for Handwritten Korean Character (필기체 한글 인식에 유용한 세선화 알고리듬의 성능 개선에 관한 연구)

  • 이기영;구하성;고형화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.5
    • /
    • pp.883-891
    • /
    • 1994
  • In this paper, we introduce new thinning algorithm which is useful for handwritten Korean character by using pixel directivity. At first, the directivity detection is performed before thinning. Each pixel is classified into the straight line of the oblique line based on its directivity. The algorithm using Rutovitz corossing number is applied to the straight line. And the algorithm using Hilditch crossing number is applied to the oblique line. The proposed algorithm is compared with six convention algorithms. Comparison criteria are similarity, noisy branch, and phoneme segmentation rate. Experiments with 570 characters have been conducted. Experimental result shows that the proposed algorithm is superior to six conventional algorithm with respect to similarity and phoneme segmentation rate.

  • PDF

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging (자기공명영상을 이용한 금속전극의 정확한 위치 결정)

  • Joe, Eun-Hae;Ghim, Min-Oh;Ha, Yoon;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2011
  • Purpose : Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. Materials and Methods : Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional ($90^{\circ}$ view) and $45^{\circ}$ oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. Results : There was least field inhomogeneity along the $45^{\circ}$ line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with $45^{\circ}$ oblique-view was coincided regardless of susceptibility. And with $45^{\circ}$ oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the $45^{\circ}$ oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. Conclusion : We suggested the method for accurate localization of electrode using $45^{\circ}$ oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery.