• Title/Summary/Keyword: Object Size Measurement

Search Result 101, Processing Time 0.025 seconds

Side Looking Vehicle Detection Radar Using A Novel Signal Processing Algorithm (새로운 신호처리 알고리즘을 이용한 측방설치 차량감지용 레이다)

  • Kang Sung Min;Kim Tae Young;Choi Jae Hong;Koo Kyung Heon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.12
    • /
    • pp.1-7
    • /
    • 2004
  • We have developed a 24GHz side-looking vehicle detection radar. A 24GHz front-end module and a novel signal processing algorithm have been developed for speed measurement and size classification of vehicles in multiple lanes. The system has a fixed antenna and FMCW processing module. This paper presents the background theory of operation and shows some measured data using the algorithm. The data shows that measured velocity of the passing vehicle is within the accuracy of 95% in single lane and the velocity of the vehicles in two lanes is within the accuracy of 90% by using variable threshold estimation. The classification of vehicle size as small, medium and large has been measured with 89% accuracy.

Orientation Analysis between UAV Video and Photos for 3D Measurement of Bridges (교량의 3차원 측정을 위한 UAV 비디오와 사진의 표정 분석)

  • Han, Dongyeob;Park, Jae Bong;Huh, Jungwon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.6
    • /
    • pp.451-456
    • /
    • 2018
  • UAVs (Unmanned Aerial Vehicles) are widely used for maintenance and monitoring of facilities. It is necessary to acquire a high-resolution image for evaluating the appearance state of the facility in safety inspection. In addition, it is essential to acquire the video data in order to acquire data over a wide area rapidly. In general, since video data does not include position information, it is difficult to analyze the actual size of the inspection object quantitatively. In this study, we evaluated the utilization of 3D point cloud data of bridges using a matching between video frames and reference photos. The drones were used to acquire video and photographs. And exterior orientations of the video frames were generated through feature point matching with reference photos. Experimental results showed that the accuracy of the video frame data is similar to that of the reference photos. Furthermore, the point cloud data generated by using video frames represented the shape and size of bridges with usable accuracy. If the stability of the product is verified through the matching test of various conditions in the future, it is expected that the video-based facility modeling and inspection will be effectively conducted.

Changes of Dynamic Stereoacuity Depending on Distance between Rods and Rod Thickness in Three Rods Test (세막대 검사에서 막대 간 거리와 막대두께 차이에 의한 동적입체시력의 변화)

  • Han, Kyung-Do;Lee, Min-Jae;Kim, Sang-Yeob;Moon, Byeong-Yeon;Yu, Dong-Sik;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.253-257
    • /
    • 2016
  • Purpose: To determine whether the distance between objects and the size of object are factors to be able to affect dynamic stereoacuity. Methods: Subjects were 37 adults (26 males and 11 females) with an average age of $23.89{\pm}1.76$. Refractive error was fully corrected for all subjects and each visual acuity of them was over 0.9. Three rods test was performed for measurement of stereoacuity. The viewing angles from left rod to right rod were set $5^{\circ}$, $10^{\circ}$, and $15^{\circ}$ and the rod thickness used 7 mm, 14 mm, and 21 mm, respectively. Stereoacuity was repeatedly measured three times in each test condition at 2.5 m distance, and reported the average value of them. Results: When rod thickness was 7 mm or 14 mm, dynamic stereoacuity decreased as the viewing angle increased, and they were significantly decreased (p<0.01) at viewing angles of $10^{\circ}$ and $15^{\circ}$ as compared with that of at $5^{\circ}$, respectively. When rod thickness was 21 mm, dynamic stereoacuity decreased as the viewing angle increased, especially, that of at $15^{\circ}$ decreased significantly (p<0.01) as compared with that of at $5^{\circ}$. The dynamic stereoacuity depending on the rod thickness have an increasing tendency as the rod thickness increased. Conclusions: The viewing angle between objects and the size of viewing object were factors that affect to dynamic stereoacuity.

A Red Ginseng Internal Measurement System Using Back-Projection (Back-Projection을 활용한 홍삼 내부 측정 시스템)

  • Park, Jaeyoung;Lee, Sangjoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.10
    • /
    • pp.377-382
    • /
    • 2018
  • This study deals with internal state and tissue density analysis methods for red ginseng grade determination. For internal measurement of red ginseng, there have been various studies on nondestructive testing methods since the 1990s, It was difficult to grasp the most important inner hole and inside whites in the grading. So in this study, we developed a closed capturing device for infra-red illumination environment, and developed an internal measurement system that can detect the presence and diameter of inner hole and inside whites. Made devices consisted of infrared lights with a high transmission rate of red ginseng in 920 nanometer wave band, a infra-red camera and a Y axis actuator with a red ginseng automatically controlled focus on the camera. The proposed algorithm performs an auto-focus system on the Y-axis actuator to automatically adjust the sharp focus of the object according to the size and thickness. Then red ginseng is rotated $360^{\circ}$ at $1^{\circ}$ intervals and 360 total images are acquired, and reconstructed as a sinogram through Radon transform and Back-projection algorithm was performed to acquire internal images of red ginseng. As a result of the algorithm, it was possible to acquire internal cross-sectional image regardless of the thickness and shape of red ginseng. In the future, if more than 10,000 different shapes and sizes of red ginseng internal cross-sectional image are acquired and the classification criterion is applied, it can be used as a reliable automated ginseng grade automatic measurement method.

Quantitative Defects Detection in Wind Turbine Blade Using Optical Infrared Thermography (광 적외선열화상을 이용한 풍력 블레이드의 결함 크기 정량화 연구)

  • Kwon, Koo-Ahn;Choi, Man-Yong;Park, Hee-Sang;Park, Jeong-Hak;Huh, Yong-Hak;Choi, Won Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.25-30
    • /
    • 2015
  • A wind turbine blade is an important component in wind-power generation, and is generally exposed to harsh environmental conditions. Ultrasonic inspection is mainly used to inspect such blades, but it has been difficult to quantify defect sizes in complicated composite structures. Recently, active infrared thermography has been widely studied for inspecting composite structures, in which thermal energy is applied to an object, and an infrared camera detects the energy emitted from it. In this paper, a calibration method for active optical lock-in thermography is proposed to quantify the size. Inclusion, debonding and wrinkle defects, created in a wind blade for 100 kW wind power generation, were all successfully detected using this method. In particular, a ${\phi}50.0mm$ debonding defect was sized with 98.0% accuracy.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

A Noncontact Optical Sensor Development for Measuring the Thickness of Transparent Plates (투명판의 두께 측정용 비접촉식 광센서 개발)

  • Ryu, Young-Kee;Oh, Choonsuk;Lee, Seoyoung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.1 s.307
    • /
    • pp.1-6
    • /
    • 2006
  • The noncontact optical sensor using the hologram laser and automatic power controller is developed to measure a thickness of transparent objects and achieve excellent performance. Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition the casting glass under high temperature results in extending the size of sensor body. The accuracy of the sensor is degraded due to these reasons. In this paper, to overcome these problems, we proposed a low cost non-contact optical sensor that is composed of a hologram laser unit used for optical pickup of CD player and a plastic lens. Therefore the problems caused by the contact sensor are solved by using the noncontact sensor. The noncontact sensor has to move toward the objects and obtain the focus error signal to measure a position of transparent objects. While the internal temperature of the sensor is controlled under ${\pm}0.1^{\circ}$, many trials shows ${\pm}2{\mu}m$ measurement error as excellent performance.

Measurement of Structural Properties of PLA Filament as a Supplier of 3D Printer (3D 프린터에 공급되는 PLA 필라멘트의 물성치 측정)

  • Choi, Won;Woo, Jae-Hyeong;Jeon, Jeong-bae;Yoon, Seong-soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.141-152
    • /
    • 2015
  • Most of agricultural structures are consisted of complex components and exposed to various boundary conditions. There have been no ways to express those structures exactly for model experiment. As an alternative, 3D printer can produce any type of solid model. However, there are limited informations related to structural experiments using 3D printer. The object of this study gives the basic informations to structural engineers who try to use 3D printer for model experiment. When PLA was used as a supplier for 3D printer, the outcomes showed less heat deformation to compare with ABS. To test the material properties, two kinds of experiments (three-point flexibility test and compression test) were executed using universal testing machine. In three-point flexibility test, plastic hinge and its deformation were developed as observed in material such as steel. The behavior was in a linear elastic state, and elastic bending modulus and yield force were evaluated. In the compression test using unbraced columns with hinge-hinge boundary condition, the constant yield forces were observed regardless of different lengths in all columns with same section size, whereas the compressive elastic modulus was increased as the length of column was increased. The suggested results can be used for model experiments of various agricultural structures consisted of single material.

Comparison of Signal to Noise Ratios in different configulation of optical coherence tomography systems (간섭계 형태에 따른 광단층 촬영장치의 SNR 비교)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.804-806
    • /
    • 2004
  • As a noninvasive imaging meathod, optical coherence tomography system has been extensively studied because it has some advantage such as imaging of high resolution, low cost, and compace size configuration. The optical power of the sample signal reflected from an object is usually very small in optical coherence tomography(OCT) due to absorption and scattering in a sample material. Furthermore, there happens a serious loss of sample signal power in a fiber coupler because it does not transfer to a photodetector but return to the optical source. In order to improve the SNR of OCT system, basic Michelson and Mach-Zehnder interferometer types were configured then, we compared simulation with measurement of reference sample Therefore, an On in configuration of Math-Zehnder interferometer was demonstrated in order to improve the signal to noise ratio

  • PDF

A Study of the Optical System of a Time-of-flight Laser Distance Sensor for a Long Distance with Minimized Divergence Beam Angle (빔 확산각 최소화를 통한 장거리 측정용 ToF 레이저 거리센서 광학계 설계 연구)

  • Lee, Hyun-Hwa;Seo, Jae-Yeong;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.79-85
    • /
    • 2021
  • In this paper, a study is conducted on the design of an optical system of a time-of-flight (TOF) laser distance sensor that can measure long distances by minimizing beam divergence. When measuring a long distance, the amount of light on the object's surface decreases as the distance increases, due to the diffusion angle of the laser beam, and thus the beam at the sensor also decreases, causing measurement errors. In general, a cylindrical lens is used to reduce the divergence beam angle. However, an optical system using a cylindrical lens has the problem of degraded performance due to the difficulty with assembly tolerance, as well as the problem of the increased size of the optical system, and thus the use of aspherical lenses has been increasing recently. Therefore, in this study, the optical efficiencies and assembly tolerances of optical systems using respectively a cylindrical lens and an aspherical lens are compared and analyzed.