OSLD와 EBT3 필름의 선량, 에너지, 방향의존성에 대한 평가 (Evaluation of OSLD and EBT3 film for dose, energy, and angular dependence)

  • Lee, Ju-seong;Kang, Bo-ram;Kwon, Hyeon-Kyung;Park, Ji-Young;Kim, Ju-Hye;Choi, Young-Se;Kim, Daehong
    • 식품보건융합연구
    • /
    • 제4권1호
    • /
    • pp.15-22
    • /
    • 2018
  • A radiation dosimeter is important to assess quality assurance (QA) of radiation therapy devices and to estimate the radiation dose in vivo dosimetry. Recently, optically stimulated luminescence detector (OSLD) is widely used in clinical filed. Therefore, the purpose of this study is to evaluate dose, energy, and angular dependence of OSLD and EBT3 film. The absorbed dose in clinical linear accelerator (Linac) beam is calibrated for dose per monitor unit (MU). Dose, energy, and angular dependence of OSLD and EBT3 film are estimated after the calibration procedure. The absorbed dose is measured at 50, 100, 150, and 200 cGy in an 6 MV X-ray beam for dose dependence. A dose of 150 cGy is delivered to OSLD and EBT3 film with 6 and 10 MV photon energies for energy dependence. For measurements of angular dependence, angular positions of gantry are $0^{\circ}{\pm}80^{\circ}$ with 6 MV at 150 cGy. The results of dose dependence is linear for OSLD and EBT3 film. For the results of energy dependence, errors were 0.39% and 0.03% for OSLD and EBT3 film, respectively. The results of dose for angular is decreased from $0^{\circ}$ to ${\pm}80^{\circ}$ for both OSLD and EBT3 film. When angle of $0^{\circ}$ is normalized to 1, and the dose is decreased to 60 and 66% at $80^{\circ}$ for OSLD and EBT3 film, respectively. Dose and energy dependence of OSLD and EBT3 film are measured within the recommendation of manufacturer. Angular dependence is increased from $0^{\circ}$ to ${\pm}80^{\circ}$ for OSLD and EBT3 film. The characteristics of OSLD and EBT3 film are similar and expected to useful for clinical field.

광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교 (Comparison on the Dosimetry of TLD and OSLD Used in Nuclear Medicine)

  • 이왕희;김성철;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제12권12호
    • /
    • pp.329-334
    • /
    • 2012
  • 방사선작업종사자의 개인피폭선량 측정에는 필름뱃지, 열형광선량계, 유리선량계 등이 이용되고 있었으며, 최근 들어 전 세계적으로 광자극발광선량계의 사용이 증가되고 있는 추세이다. 하지만 우리나라에서는 아직 일부에만 적용되고 있으며, 연구도 거의 없는 실정이다. 이에 기존에 가장 많이 사용되고 있던 열형광선량계와 광자극발광선량계를 핵의학과 작업종사자 및 작업구역에서 3개월간 누적선량을 비교해 보았으며, 그 결과 평균 표층선량은 열형광선량계가 1.27mSv, 광자극발광선량계가 2.12mSv로 0.85mSv의 차이가 있었으며, 평균 심부선량은 열형광선량계가 1.33mSv, 광자극발광선량계가 2.06mSv로 0.73mSv의 차이를 보였다. 광자극발광선량계가 표층선량 및 심부선량 모두에서 통계적으로 유의하게(p<0.05) 높게 측정하는 것으로 나타났다.

형광유리 선량계와 광자극 발광선량계를 이용한 핵의학과 선량 측정비교 (Comparison on the Dosimetry of OSLD and PLD Used in Nuclear Medicine)

  • 박정규;손상준;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권1호
    • /
    • pp.47-51
    • /
    • 2019
  • This study was conducted from July 1 to September 30, 2018 using Optically Stimulated Luminescence Dosimeter(OSLD) and photoluminescent glass dosimeter(PLD) to measure the 3-month exposure dose and the cumulative dose in the active working area of the nuclear medicine worker Respectively. As a result, the cumulative dose for three months in the worker and work area was measured as 1.97 mSv and 2.02 mSv in the PLD. The mean surface dose and the mean depth dose of the OSLD were measured to be 2.04 mSv. The difference in the total surface dose measured by the PLD and the OSLD was 0.66mSv and the total mean surface dose was 0.07mSv. The difference between the total depth dose and the total depth dose was 0.1mSv and 0.02mSv, respectively. It was found that the dose value of the OSLD was higher than that of the PLD. In addition, it was found that the maximum difference of 0.01mSv was observed between the PLD and the OSLD of the worker. For the dose measurement of the two dosimetry systems, there was no significant difference between the PLD and the OSLD in the surface dose of 0.239 (p>0.05). Also, the significance of PLD and OSLD in the deep dose was 0.109, which was not statistically significant (p>0.05).

광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰 (Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry)

  • 김정미;전수동;백금문;조영필;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.123-129
    • /
    • 2010
  • 목 적: 방사선 치료의 선량평가를 위해 사용되는 Optically stimulated luminescent dosimeters (OSLD) 선량 특성을 분석하여, 선량 측정의 유용성을 알아보고자 한다. 대상 및 방법: $NanoDot^{TM}$$Inlight^{TM}$MicroStar Reader, Solid Water Phantom, 의료용 선형가속기 $TRYLOGY^{(R)}$를 사용하였다. 측정 조건은 OSLD를 Solid Water Phantom의 $D_{max}$ 깊이에 위치시킨 후 SSD는 100 cm, Field size는 $10{\times}10\;cm^2$로 하고 300 MU/min으로 6 MV 광자선, 100 cGy의 방사선을 조사하였다. OSLD를 10분 마다 판독하면서 변화값을 측정하였고, OSLD에 선량을 50 cGy와 100 cGy씩 누적시켜 판독하였다. 또한 에너지 의존성은 6 MV, 15 MV, 4~20 MeV를 사용하였다. 선량률은 100~1,000 MU/min로 변화시키면서 측정하였다. 광자선 6 MV의 PDD의 변화를 측정하기 위해 OSLD와 전리함(Ionization chamber) (FC 65P-747)을 사용하였다. 결 과: 시간의 경과에 따른 OSLD의 재현성은 ${\pm}2.5%$였다. OSLD의 선량에 대한 선형성(linearity)을 평가한 결과 300 cGy까지는 선형적으로 증가하였고, 300 cGy 이상에서는 초선형적(supralinearity)으로 증가하였다. 에너지 의존성은 ${\pm}2%$ 이내였고 선량율 의존성은 ${\pm}3%$ 이내였다. 6 MV 광자선에 대하여 OSLD로 측정한 $PDD_{10}$은 66.7%, $PDD_{20}$은 38.4%였고 전리함(Ionization chamber)으로 측정한 $PDD_{10}$은 66.6%, $PDD_{20}$은 38.3%였다. 결 론: OSLD의 특성을 분석한 결과 시간, 에너지, 선량률의 변화에 따른 차이는 ${\pm}3%$ 이내였으며 전리함(Ionization chamber)과 비교한 PDD는 0.3% 이내였다. 또한 300 cGy까지는 선량이 선형적으로 증가하였다. OSLD는 여러 번 반복 측정이 가능하였고 측정과 판독이 용이하여 선량계로서 유용성을 확인하였다.

  • PDF

진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비 (Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation)

  • 강영한;권순무;김부순
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.499-505
    • /
    • 2012
  • 개인피폭선량계인 열형광선량계(TLD)와 광자극형광선량계(OSLD)를 진단방사선 영역에서 사용할 때 에너지와 조사 횟수, 투시촬영 시간, 산란선 노출 일 수 등에 따라 측정값이 차이가 있는지를 상대비와 상대비 간격으로 알아보았다. 에너지에 따라서는 TLD의 상대비($1.81{\pm}0.41$)가 OSLD의 상대비($1.40{\pm}0.26$)보다 높았고, 조사 횟수에 따라서는 TLD의 상대비($2.10{\pm}0.10$,)보다 OSLD의 상대비($2.33{\pm}0.09$)가 더 높았다. 투시촬영 시간에 따른 상대비와 산란선 노출일수에 따른 상대비는 두 선량계가 유의한 차이가 없었으나 산란선 노출일수에 따른 상대비의 간격이 0.2 이내로 나타나 직접선의 상대비 간격보다 좁았다. 이는 직접선의 측정결과보다 산란선의 측정에 있어 TLD와 OSLD의 결과값에 신뢰가 높다고 할 수 있다. 따라서 방사선 피폭상황에 따라 선량계 간에 상대비가 다소 차이가 날 수 있음을 인지하고, 경우에 따라서는 두 가지 선량계를 이용하여 교차평가를 함으로써 선량 측정 결과값에 대한 신뢰성을 높일 수 있을 것이다.

방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가 (Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter)

  • 강인석;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제14권11호
    • /
    • pp.864-870
    • /
    • 2014
  • 선량계 유용성을 평가하기 위한 방법으로 방사선관계종사자의 피폭선량을 측정하여 개인피폭관리를 위한 선량계 선택의 기초 자료를 제시하고자 하였다. 2012년 1년간 방사선사 30명을 대상으로 하였으며 개인피폭 누적선량을 측정하여 열형광선량계, 형광유리선량계, 광자극발광선량계의 성능을 조사하였다. 연구방법으로는 DAP와 ion-chamber를 이용하여 세종류 개인피폭선량계의 선량측정값을 비교 분석하였으며 의료기관별, 검사업무별, 분기별 방사선관계종사자의 피폭누적선량을 확인하였다. 결과적으로 직접 X선조사를 통한 개인피폭선량계의 선량값과 ion-chamber의 절대값에서 광자극발광선량계가 열형광선량계나 형광유리선량계에 비해 더 유사한 선량값을 나타내 측정 능력면에서 더 우수한 결과를 나타냈다. 또한 방사선발생구역에서 방사선관계종사자의 피폭선량이 광자극발광선량계에서 보다 높게 나타났다.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

영상의학과에서 사용되는 광자극 형광선량계와 전자식 개인선량계의 방향 의존성 비교 (The comparison of angular dependence for optical stimulated luminescence dosimeter(OSLD) and electronic personal dosimeter(EPD) used in Diagnostic Radiology)

  • 권순무;박정규;김부순
    • 디지털콘텐츠학회 논문지
    • /
    • 제16권3호
    • /
    • pp.463-470
    • /
    • 2015
  • 최근 개인선량계로 사용이 증가하고 있는 수동형 선량계인 OSLD와 능동형 선량계인 EPD의 상대 반응도(relative response), 측정 불확도(uncertainty of measurement)를 계산하여 방향의존성(angular dependence)을 비교, 분석하였다. OSLD는 수평, 수직방향의 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위에서 평균 상대 반응도는 0.97, 0.95의 작은 변화를 보였고 방향의존성에 대한 불확도는 0.65, 0.62로 전체 불확도에 미치는 영향은 미미한 것으로 판단되었다. EPD는 $0^{\circ}{\sim}{\pm}60^{\circ}$ 범위에서 수평, 수직방향 평균 상대 반응도는 0.94, 0.97로 확인되어 IEC 61526 규정을 만족하였다. 방향의존성에 대한 불확도는 수평, 수직방향에서 0.44, 0.40로 전체 불확도에 미치는 영향은 미미하였다. 그러나 수평방향에서 $+90^{\circ}$, $-90^{\circ}$ 방향의 상대 반응도는 0.60, 0.37이고 수직방향에서 $+90^{\circ}$ 방향의 반응도는 0.06으로 반응도의 큰 변화를 관찰할 수 있었다. OSLD의 방향 의존성은 $0^{\circ}{\sim}{\pm}90^{\circ}$ 범위까지 EPD에 비해 우수하였으며 EPD의 경우 구조적 특징으로 반응도가 급변하는 특정방향이 존재하였다. 따라서 수동형선량계와 보조선량계의 병행사용이 개인피폭선량측정의 정확도를 기할 수 있을 것으로 판단된다.

유방암 환자의 수술 중 방사선치료 시 피부선량 측정을 통한 안전성 평가 (Evaluation of safety by skin dosimetry in Intraoperative Radiotherapy for breast cancer patients)

  • 정인호;김준원;박광우;하진숙;전미진;조윤진;김세준;김종대;신동봉
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2015
  • 목 적 : 유방암 환자를 대상으로 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(Intraoperative Radiotheray, IORT)를 국내에 처음 도입하는데 있어 광자극형광선량계(Optically Stimulated Luminescent Dosimeter, OSLD)를 이용한 피부선량측정을 통해 Intrabeam$^{TM}$ system의 안정성을 평가하고자 한다. 대상 및 방법 : 본원에서 2014년 8월부터 2015년 2월까지 유방보존술(breast-conserving surgery, BCS)후 Intrabeam$^{TM}$ system을 이용하여 수술 중 방사선치료(IORT)를 시행한 30명의 유방암 환자를 대상으로 진행하였다. 처방선량은 applicator 표면을 기준으로 20 Gy로 설정하여 1 cm 떨어진 지점에 약 5 Gy의 선량이 전달될 수 있도록 하였다. 종양 크기에 따라 applicator의 크기를 결정하였고 치료시간은 applicator의 크기에 따라 18~40분으로 설정되었다. 피부 절개면에서 Superior, Inferior, Lateral, Medial 4방향에 applicator를 중심으로부터 0.5 cm와 1.5 cm지점에 광자극형광선량계(OSLD)를 각각 부착하였다. 각 방향에 따라 U1,U2(Superior), D1,D2(Inferior), L1,L2(Lateral), M1,M2(Medial)로 총 8지점을 지정하였다. 각 지점에서의 측정값과 모든 지점의 평균값 및 최고값, 최저값을 산출하여 비교분석 하였다. 결 과 : Intrabeam$^{TM}$ system 50kVp X-ray source를 이용한 수술 중 방사선치료(IORT)시 OSLD의 측정 결과 U1 $2.23{\pm}0.80Gy$, U2 $1.54{\pm}0.53Gy$, D1 $1.73{\pm}0.63Gy$, D2 $1.25{\pm}0.45Gy$, L1 $1.95{\pm}0.82Gy$, L2 $1.38{\pm}0.42Gy$, M1 $2.03{\pm}0.70Gy$, M2 $1.51{\pm}0.58Gy$로 나타났으며 maximum값은 U1지점에서 4.34 Gy, minimum값은 M2지점에서 0.45 Gy로 나타났다. 전체 환자 중 13.3 %(N=4/30) 환자에서 4 Gy를 초과하는 측정값이 나타나 그 원인을 분석하였다. 결 론 : 본 연구를 통해 현재 본원에서 도입한 Intrabeam$^{TM}$ system을 이용한 수술 중 방사선치료(IORT)는 모든 환자의 피부선량값이 5 Gy미만으로 측정된 것으로 보아 그 안전성이 확인되었다. 피부선량이 4 Gy를 초과한 환자의 데이터 분석을 통해 breast volume이 상대적으로 작은 사이즈의 유방암환자의 경우 피부선량이 증가하는 경향을 보여 수술 중 방사선 치료 대상 환자 선정시 종양의 크기와 위치 뿐만 아닌 breast volume 값 등을 고려하여 피부에 전달되는 선량값이 기준값을 초과하지 않도록 주의 하여야 한다.

  • PDF

Prediction of Midline Dose from Entrance and Exit Dose Using OSLD Measurements for Total Body Irradiation

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Background: This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). Materials and Methods: For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. Results and Discussion: The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. Conclusion: The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.