• 제목/요약/키워드: OSL dosimetry

검색결과 11건 처리시간 0.018초

Study of Neutron Detection with OSL

  • 홍덕균;김명진;박세환;이정일
    • 대한방사선방어학회:학술대회논문집
    • /
    • 대한방사선방어학회 2011년도 추계 학술발표회 및 심포지엄
    • /
    • pp.290-291
    • /
    • 2011
  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

선량 판독용 OSL 측정장치의 개발 (Development of OSL Dosimetry Reader)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 개인 선량계로 활용될 수 있는 광자극발광(OSL: optically stimulated luminescence) 측정장치의 개발과 이를 위한 이론적 배경 및 개발된 장치의 성능에 대하여 기술하였다. OSL 측정장치는 자극광원과 시료로부터 자극 발광된 광신호 사이의 간섭효과를 최소화하기 위하여 다양한 광학적 필터 조합을 구성해야 하는데, 여기서는 자극광에는 GG420 필터를, 측정부에는 UG11과 BG39 필터로 $Al_2O_3:C$ OSL 물질에 최적화된 광학적 필터를 구성하였다. 자극광원으로 Luxeon V형 고휘도 Blue LED를 선택함으로서 충분한 광량을 확보하였다. 또한 장비 제어 및 측정을 위하여 PC와 OSL 장치 사이에 다양한 제어보드들이 이용되며, 전체 장치의 자동화 및 장치제어는 LabView 프로그램을 이용하여 개발하였다. 개발된 OSL 장치의 신뢰도 및 재현성 평가를 위해 대표적인 OSL 물질인 $Al_2O_3:C$를 이용하여 OSL 특성곡선을 측정하고 이를 기존 상용 OSL 측정장치와 비교하였다.

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

광자극선량계의 저에너지 엑스선 특성비교 (Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots)

  • 정숙진;진계환
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.79-83
    • /
    • 2018
  • 본 논문에서는 OSL 도트 선량계의 교정인자, 흡수선량 선형성, 피크전압 선형성, 각도 변화에 의한 흡수선량 변화를 측정하고 분석했다. 의료용 X 선발생 장치를 사용하여 조사에 노출 선량 보정 계수, 흡수선량 선형성, 피크 전압 선형성은 모두 IEC-62387-1 (2007) 기준을 만족하였다. 기준 방사선 노출과 관련하여 0도, 30도 및 60도에서 선량계 방향에 대한 기준은 -29 % (${\pm}30^{\circ}$) 및 + 67 % (${\pm}60^{\circ}$)이었다. 30도에서 측정된 값은 기준보다 -8 % 낮고 60도에서 기준보다 -18 % 낮게 나타났다. 그러므로 OSL 도트 선량계 사용 시 방향에 따른 영향을 보정하여야 한다.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

열자극발광 및 광자극발광 측정장치의 개발 (Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System)

  • 박창영;정기수;이종덕;장인수;이정일;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2015
  • 열이나 빛의 자극에 의한 물질의 발광현상, 즉 열자극발광(thermoluminescence, TL)과 광자극발광(optically stimulated luminescence, OSL)의 메커니즘을 규명하고, 이 현상을 방사선량의 측정에 활용할 수 있는 새로운 발광물질을 개발하는데 활용할 수 있는 측정장치를 개발하였다. 이는 열자극과 광자극을 동시에 가할 수 있는 장치로서, 열자극에 필요한 온도제어를 위하여 35 kHz의 정현파 전원으로 변환하여 스트립 형태의 발열부에 걸어주게 되며, 최대 $20K{\cdot}s^{-1}$의 온도상승률로 약 1K의 정밀도로 온도를 제어할 수 있었다. 광자극을 위한 광원으로 중심파장이 470 nm인 Luxeon V형 고휘도 LED 등 여러 파장영역의 LED나 레이저를 사용할 수 있도록 하였다. 대표적으로 470 nm의 LED로 $Al_2O_3$:C의 OSL을 측정하는 경우, 시료의 발광에서 자극광을 분리시키기 위하여 LED의 자극광은 단파장차단필터인 GG420을 통과시켜서 시료에 걸리게 하고, 시료의 발광은 대역통과필터인 UG11를 통과하여 광증배관에 걸리게 하였다. 아울러 시료에 따라 LED나 필터들을 다르게 조합할 수 있도록 하여 시료의 발광특성에 맞는 최적의 측정을 수행할 수 있다. PC로 측정장치의 전체적인 제어가 이루어지며 LabView로 개발한 제어프로그램은 그래픽사용자환경(GUI)으로 되어 있다. 이 연구를 통해서 개발한 장치로 LiF:Mg,Cu,Si와 $Al_2O_3$:C를 표준시료로 하여 TL과 OSL을 측정하였고, 이들의 발광특성이 기존에 알려진 특성을 재현하여 이 장치가 신뢰할 수 있는 성능을 내는 것을 확인할 수 있었다.

광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정 (Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs))

  • 임인철;유윤식;이재승
    • Journal of Radiation Protection and Research
    • /
    • 제36권2호
    • /
    • pp.86-92
    • /
    • 2011
  • 본 연구는 최근 생체내선량측정에서 유용성을 재평가 받고 있는 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)와 다이오드 검출기를 병행하여 직장암 방사선치료 환자의 피부선량을 측정하고 치료계획시스템 에서 계산 선량과 측정 선량을 비교하여 OSL 선량계의 임상적 유용성을 평가하고자 하였다. 각 OSL 선량계의 고유한 교정상수를 측정하고 10 명의 직장암 환자를 대상으로 3 부위를 설정하여 측정하였다. 기준 흡수선량 100 cGy에 대하여 OSL 선량계의 교정상수는 6 MV X-선의 경우 1.17, 10 MV X-선의 경우 1.28 이었다. 또한 직장암 환자들의 피부선량은 측정 부위별로 치료계획시스템에서 계산 선량과 비교하여 다이오드 검출기는 1.16 ~ 2.83%의 선량증가를 보였고 OSL 선량계는 1.36 ~ 2.17%의 선량증가를 보였다. 특히 피부면의 굴곡이 심한 회음부(perineum)에서 계산된 선량과 전달 선량간 차이가 증가되었으며 다이오드 검출기보다 OSL 선량계가 측정값의 변화가 상대적으로 작았다. 따라서 OSL 선량계는 기존에 사용하던 이온함 및 다이오드 검출기를 대신하여 방사선량학적 오차의 검증 및 생체내선량측정에서 임상적으로 적용이 가능하였으며 직장암 환자의 굴곡이 심한 회음부 주변의 선량 평가에 대한 연구가 계속되어야 할 것으로 판단된다.

광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰 (Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry)

  • 김정미;전수동;백금문;조영필;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.123-129
    • /
    • 2010
  • 목 적: 방사선 치료의 선량평가를 위해 사용되는 Optically stimulated luminescent dosimeters (OSLD) 선량 특성을 분석하여, 선량 측정의 유용성을 알아보고자 한다. 대상 및 방법: $NanoDot^{TM}$$Inlight^{TM}$MicroStar Reader, Solid Water Phantom, 의료용 선형가속기 $TRYLOGY^{(R)}$를 사용하였다. 측정 조건은 OSLD를 Solid Water Phantom의 $D_{max}$ 깊이에 위치시킨 후 SSD는 100 cm, Field size는 $10{\times}10\;cm^2$로 하고 300 MU/min으로 6 MV 광자선, 100 cGy의 방사선을 조사하였다. OSLD를 10분 마다 판독하면서 변화값을 측정하였고, OSLD에 선량을 50 cGy와 100 cGy씩 누적시켜 판독하였다. 또한 에너지 의존성은 6 MV, 15 MV, 4~20 MeV를 사용하였다. 선량률은 100~1,000 MU/min로 변화시키면서 측정하였다. 광자선 6 MV의 PDD의 변화를 측정하기 위해 OSLD와 전리함(Ionization chamber) (FC 65P-747)을 사용하였다. 결 과: 시간의 경과에 따른 OSLD의 재현성은 ${\pm}2.5%$였다. OSLD의 선량에 대한 선형성(linearity)을 평가한 결과 300 cGy까지는 선형적으로 증가하였고, 300 cGy 이상에서는 초선형적(supralinearity)으로 증가하였다. 에너지 의존성은 ${\pm}2%$ 이내였고 선량율 의존성은 ${\pm}3%$ 이내였다. 6 MV 광자선에 대하여 OSLD로 측정한 $PDD_{10}$은 66.7%, $PDD_{20}$은 38.4%였고 전리함(Ionization chamber)으로 측정한 $PDD_{10}$은 66.6%, $PDD_{20}$은 38.3%였다. 결 론: OSLD의 특성을 분석한 결과 시간, 에너지, 선량률의 변화에 따른 차이는 ${\pm}3%$ 이내였으며 전리함(Ionization chamber)과 비교한 PDD는 0.3% 이내였다. 또한 300 cGy까지는 선량이 선형적으로 증가하였다. OSLD는 여러 번 반복 측정이 가능하였고 측정과 판독이 용이하여 선량계로서 유용성을 확인하였다.

  • PDF

유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구 (A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon)

  • 홍동희;정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.81-87
    • /
    • 2015
  • 유방의 피폭선량을 줄이기 위해 압박대의 재질을 연구하였으며, 재질로는 PC, PMMA, Carbon을 이용한 방사선 투과성 및 선질 등을 측정하였고, 영상을 통한 화질도 분석하여 다음과 같은 결론을 얻었다. Unfors Xi dosimetry 사용 시 방사선 투과율은 압박대를 제거 후 측정한 결과 8.353 mGy가 나왔으며, PC 6.308 mGy, PMMA 6.223 mGy, Carbon 7.218 mGy가 측정되었다. 반가층은 PC 0.375mmAl, PMMA 0.370mmAl, Carbon 0.360mmAl으로 Carbon, PC, PMMA 순으로 높은 선질과 투과도를 보였다. InLight/OSL NanoDotTM dosimeters 사용 시 압박대를 제거 후 선량계를 위치시켜 측정한 결과 중심부위에서 1.143 mGy, 가장자리에서 12.56 mGy, PC 중심부위에서 8.990 mGy, 가장자리에서 10.291 mGy, PMMA 중심부위에서 8.391 mGy, 가장자리에서 9.654 mGy, Carbon 중심부위에서 9.581 mGy, 가장자리에서 11.313 mGy가 측정되어 Carbon, PC, PMMA 순으로 높은 투과도를 보였다. Image J에서 Pixel 평균값은 압박대를 제거한 후 976.655, PC 831.032, PMMA 819.069, Carbon 897.118로 Carbon, PC, PMMA순으로 높게 측정되었다.