• 제목/요약/키워드: OPEN WATER

검색결과 1,879건 처리시간 0.03초

통합 물환경 관리를 위한 개방형 모델링 플랫폼 고찰 (A Review of Open Modeling Platform Towards Integrated Water Environmental Management)

  • 이성학;신창민;이용석;조재필
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.636-650
    • /
    • 2020
  • A modeling system that can consider the overall water environment and be used to integrate hydrology, water quality, and aquatic ecosystem on a watershed scale is essential to support decision-making in integrated water resources management (IWRM). In adapting imported models for evaluating the unique water environment in Korea, a platform perspective is becoming increasingly important. In this study, a modeling platform is defined as an ecosystem that continuously grows and provides sustainable values through voluntary participation- and interaction-of all stakeholders- not only experts related to model development, but also model users and decision-makers. We assessed the conceptual values provided by the IWRM modeling platform in terms of openness, transparency, scalability, and sustainability. I We also reviewed the technical aspects of functional and spatial integrations in terms of socio-economic factors and user-centered multi-scale climate-forecast information. Based on those conceptual and technical aspects, we evaluated potential modeling platforms such as Source, FREEWAT, Object Modeling System (OMS), OpenMI, Community Surface-Dynamics Modeling System (CSDMS), and HydroShare. Among them, CSDMS most closely approached the values suggested in model development and offered a basic standard for easy integration of existing models using different program languages. HydroShare showed potential for sharing modeling results with the transparency expected by model user-s. Therefore, we believe that can be used as a reference in development of a modeling platform appropriate for managing the unique integrated water environment in Korea.

Release of Ammonia Odor from AAFA (Ammonia Adsorbed Fly Ash) by Installation of NOx Reduction System

  • Kim, Jae-kwan;Park, Seok-un;Lee, Hyun-dong;Chi, Jun-wha
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.437-445
    • /
    • 2016
  • This paper discussed the effect of ammonia concentration adsorbed on fly ash for the ammonia emission as AAFA (Ammonia Adsorbed Fly Ash) produced from coal fired plants due to operation of NOx reduction technologies was landfilled with distilled or sea water at closed and open systems, respectively. Ammonia bisulfate and sulfates adsorbed on fly ash is highly water soluble. The pH of ammonium bisulfate and sulfate solution had significant effect on ammonia odor emission. The effect of temperature on ammonia odor emission from mixture was less than pH, the rate of ammonia emission increased with increased temperature when the pH conditions were kept at constant. Since AAFA increases the pH of solution substantially, $NH_3$ in the ash can release the ammonia order unless it is present at low concentration. $NH_4{^+}$ ion is unstable in fly ash and water mixtures of high pH at open system, which is changed to nitrite or nitrate and then released as ammonia gas. The proper conditions for < 20 ppm of ammonia concentration released from the AAFAs landfilled in ash pond were explored using an open system with sea water. It was therefore proposed that optimal operation to collect AAFA of less than 168 ppm ammonia at the electrostatic precipitator were controlled to ammonia slip with less than 5 ppm at SCR/SNCR installations, and, ammonia odor released from mixture of fly ash of 168 ppm ammonia with sea water under open system has about 20 ppm.

Comparisons of Ion Balance, Fruit Yield, Water, and Fertilizer Use Efficiencies in Open and Closed Soilless Culture of Paprika (Capsicum annuum L.)

  • Ko, Myat Thaint;Ahn, Tae In;Son, Jung Eek
    • 원예과학기술지
    • /
    • 제31권4호
    • /
    • pp.423-428
    • /
    • 2013
  • Although closed soilless culture is useful for saving water and fertilizers with minimizing environmental pollution, adequate management of nutrient solutions is still not stabilized in greenhouse cultivation. In order to investigate the problems occurred in closed soilless culture of Paprika (Capsicum annuum L., cv. Fiesta), we compared ion balance, fruit yield, and the water and fertilizer use efficiencies in the closed system with those in the open system. The plants were grown in rockwool culture with a nutrient solution of EC $2.5dS{\cdot}m^{-1}$. After 4 weeks of treatment, individual ratio of $NO{_3}^-$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$ to total ion concentrations ($meq{\cdot}L^{-1}$) decreased from the initial value, especially the biggest decrement was observed in $K^+$, and on the other hand, $SO{_4}^{2-}$, $Cl^-$, and $Na^+$ were accumulated in the closed system. Yields after four-time harvests were 19% higher in the open system than in the closed system. Total volume of water used per unit area ($m^2$) in the open system was 20% higher, but the total water use per fruit was not significantly different between the two systems, while t total fertilizer use per fruit was 78% higher in the closed system. Amount of marketable fruits was not significantly different between the two systems. We concluded that the increase in $K^+$ supply and the replenishment of recycled nutrient solution every four weeks were required for preventing the imbalance or depletion of nutrients in the close soilless culture of paprika plants to get more balanced nutrient composition during whole cultivation period.

전해산성수를 이용한 암모니아 중화와 제거 (Ammonia neutralization and removal using electrolyzed-acidic water)

  • 최원경
    • 한국융합학회논문지
    • /
    • 제12권5호
    • /
    • pp.185-190
    • /
    • 2021
  • 전기분해 공정으로 제조한 전해산성수를 이용하여 생활 악취의 원인인 암모니아를 제거하는 방법을 연구하였다. 제조한 전해산성수는 pH와 ORP 변화 측정을 통해 안정적으로 알칼리성 암모니아를 중화 시킬 수 있는 전해수(중화제)로 확인되었다. 자외-가시선 흡광도 분석과 전기화학적 개방회로 전위 측정으로 전해산성수와 암모니아수를 혼합한 용액에서 암모니아가 제거되는 것을 확인하였다. 암모니아 가스 발생량 측정을 통해 전해산성수가 암모니아를 중화시켜 악취 발생시키는 암모니아가 효과적으로 제거되는 것으로 조사되었다. 친환경적인 전해산성수가 악취의 원인 물질인 암모니아를 효과적으로 안전하게 제거할 수 있는 것으로 확인되었다.

개수로의 단면축소로 인한 수면변화 (variation of Water Surface due to constriction in Open Channel)

  • 조용준;차영기;윤태훈
    • 물과 미래
    • /
    • 제18권4호
    • /
    • pp.361-367
    • /
    • 1985
  • 수리구조물에 의하여 하천단면의 감소로 유발되는 수면의 변화를 수치적으로 해석하였다. 수면변화는 수축화와 등류의 Froude No.에 가장 민감하게 나타났으며, 수면의 변화로부터 구한 배수는 Skogerboe의 실험식과 매우 잘 맞았다. 이는 배수의 크기는 수치해석법으로 예측할 수 있음을 시사한다.

  • PDF

CFD Simulation about Green Water on a Fixed FPSO in Regular Waves

  • Ha, Yoon-Jin;Nam, Bo Woo
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제3권4호
    • /
    • pp.174-183
    • /
    • 2017
  • Numerical simulations were performed about the green water problem of a FPSO. Three regular waves in head sea were tested. A rectangular box-shaped FPSO was considered and it is assumed there is a vertical wall on the deck. For the numerical simulations, an open-source CFD code, OpenFOAM, was applied to solve the present problems. Focus is on wave fields around the FPSO, water flows and impact pressures on the deck. For the validation, the present calculation results were compared with the existing experimental of Lee et al. (2012) and Changwon university in KTTC Cooperative Study Report (2015). The statistical values and spatial distribution of the peak pressures are directly compared with the experimental data. Some discussions are made on the effects of the domain breadth on the Green water impact pressure.

하부 대수층이 존재하는 연약지반상의 개착터널에 있어서 지하수 처리 사례 (Ground water control in the open cut site on soft ground with aquifer)

  • 정재형;;;배규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1420-1425
    • /
    • 2005
  • In a case of an example in Korea, some areas of Yangsan near Busan which exist on soft ground with aquifer, showed us some difficulties of the preparing for housing site and earth structures. From these experiences, recently, the development and research of technology is getting increased, which minimize the influence to the environment from construction work, which is in an agreement with eco-friendly construction in terms of the reasonable processing of ground water. On this case study, one area of Japan that has many site on soft ground with aquifer, is introduced as the reasonable processing of ground water. The applications of the technology for ground water in Korea are discussed.

  • PDF

전력 및 담수생산을 위한 해양온도차발전에 대한 연구 (Study on OTEC for the Production of Electric Power and Desalinated Water)

  • 박성식;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.124-130
    • /
    • 2010
  • Ocean Thermal Energy Conversion(OTEC) power plants have been examined as a viable option for supplying clean energy. This paper evaluated the thermodynamic performance of the OTEC Power system for the production of electric power and desalinated water. The results show that newly developed fluids such as R32, R125, R143a, and R410A that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. Overall cycle efficiency of open cycle is the lowest value of 3.01% because about 10% of the gross power is used for pumping out non-condensable gas. Also, the hybrid cycle is an attempt to combine the best features and avoid the worst features of the open and closed cycles. The overall cycle efficiency of hybrid cycle is 3.44% and the amount of desalinated water is 0.0619 kg/s.

Internal Flow Analysis on an Open Ducted Cross Flow Turbine with Very Low Head

  • Wei, Qingsheng;Hwang, Yeong-Cheol;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.67-71
    • /
    • 2014
  • Recently, the cross flow turbine attracts more and more attention for its good performance over a large operating regime at off design point. This study adopts a very low head cross flow turbine that has barely been studied before, and investigates the effect of air layer on the performance of the cross flow turbine. As open duct is applied in this study and free surface model is used between the air layer and water, an engineering definition of efficiency, instead of traditional definition of efficiency, is used. As torque at the runner fluctuates up and down at a reasonable limit, statistical method is used. Pressure and water volume fraction contours are shown to present the characteristics of air-water flow. With constant air suction in the runner chamber, the water level gradually drops below the runner and efficiency of the turbine can be raised by 10 percent. All considered, the effect of air layer on the performance of turbine is considerable.

Spectral Distribution and Spectral Absorption of Suspended particulates in Waters of Sanya Bay

  • Yang, Dingtian;Cao, Wenxi
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.495-498
    • /
    • 2006
  • Optical profile and spectral absorption of suspended solids in waters of Sanya bay was measured on August 8-14, 2003. Optical profile was taken by using MicroPro optical profile. Apparent optical indexes, vertical diffuse attenuation coefficient ($K_d$) and water leaving radiance (Lw), were calculated. $K_d$ at the blue end of the spectrum was greater than that at the red end of the spectrum in waters near Sanya River mouth, however, in waters near open sea, $K_d$ at the blue end of the spectrum was smaller than that at the red end of the spectrum. Distribution of water leaving radiance was relatively higher in waters near Sanya River mouth, but relatively weaker in near open sea water. Spectral absorption of suspended particulates was also measured. Results showed that the spectral absorption of chlorophyll a was greater in waters near Sanya river mouth, but relatively weaker in waters near open sea, which indicated higher concentration of phytoplankton in waters near Sanya river mouth. Except for water at the 5th sampling station, the ratio of spectral absorption of chlorophyll a to total suspended particulates in surface waters was greater than that in bottom waters at all stations.

  • PDF