• 제목/요약/키워드: ON

Search Result 814,817, Processing Time 0.639 seconds

Study on Measurements of the Mandible BMD According to the ROI Variation (관심영역 변화에 따른 하악골 골밀도 측정에 대한 연구)

  • Tak, Jeong-Nam
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.

  • PDF

Relationship Between Carotid Intima-Media Thickness Using Ultrasonography and Diagnostic Indices of Metabolic Syndrome (초음파를 이용한 경동맥 내-중막 두께와 대사증후군 진단지표의 연관성)

  • Ko, Kyung-Sun;Heo, Kyung-Hwa;Won, Yong-Lim;Lee, Sung-Kook;Kim, Ki-Woong
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.285-291
    • /
    • 2009
  • The aim of the present study was undertaken to investigate the association between diagnostic indices of metabolic syndrome(MetS) with carotid intima-media thickness using ultrasonography. The participants in the study were 315 male employees without carotid atherosclerosis and other cardiovascular disease. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. Anthropometric parameters and biochemical characteristics were done using each specific equipments and the NCEP-ATP III criteria were used to define MetS. They were examined by B-mode ultrasound to measure the carotid intima-media thickness(carotid IMT) at the near and far walls of common carotid and bifurcation(bulb). The mean carotid IMT was $0.739{\pm}0.137\;mm$ and it's thickness significantly increased with the increase in age. Also, amounts of systolic and diastolic blood pressure, triglyceride and fasting glucose were significantly increased with the increase in age. Carotid IMT were significantly correlated with BMI(r=0.170, p=0.004), systolic(r=0.148, p=0.011) and diastolic blood pressure(r=0.123, p=0.036) and HDL-cholesterol(r=-0.164, p=0.005). On multiple logistic regression analysis for the diagnostic indices of MetS, carotid IMT were significantly associated with blood pressure(OR=4.220, p<0.01) and MetS(OR=1.301, p<0.05). The results indicate that blood pressure and MetS are important risk factors for carotid atherosclerosis.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Analysis of Bone Mellow Density in Adults of Domestic Local Area Using Multi-Detector Computed Tomography: Focus on Corelation About Eating Habits, Lifestyle, Physical Features and Social Characteristics (다중 검출 전산화단층촬영을 이용한 국내 일부 지역 성인의 골밀도 현황 분석: 식습관, 생활습관, 신체적, 사회적 특성과의 상관관계를 중심으로)

  • Lee, Tae Hui;Kim, Tae-Hyung;So, Woon Young;Lim, Hei Gyeom;Lim, Cheong-Hwan;Park, Myeong Hwan;Cheoun, Myung-Ki
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.517-526
    • /
    • 2016
  • This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT (multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference (p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Effect of Pre-wilting on the Forage Quality of Organic Sorghum$\times$Sudangrass Silage (예건이 수수$\times$수단그라스 교잡종 유기 사일리지의 품질에 미치는 영향)

  • Lim, Hyun-Jin;Kim, Jong-Duk;Lee, Hyun-Jin;Jeon, Kyeong-Hup;Yang, Ka-Young;Kwon, Chan-Ho;Yoon, Sei-Hyung
    • Korean Journal of Organic Agriculture
    • /
    • v.17 no.4
    • /
    • pp.519-527
    • /
    • 2009
  • The main nutritional problem of sorghum$\times$sudangrass hybrid silage is low quality and dry matter (DM) contents. This experiment was conducted to evaluate whether field pre-wilting treatment of sorghum$\times$sudangrass hybrid silage increases DM content and forage quality of the silage. The experiment was a randomized complete block design with three replications. The treatments were consisted of five different wilting days: 0 day (direct cut silage), 0.5 day, 1 day, 2 days and 3 days. Sorghum$\times$sudangrass hybrid silage with pre-wilting showed low 4.00 pH values, however direct cut silage (control) showed a 4.30 value because of its high moisture content. The DM content of sorghum$\times$sudangrass hybrid silage with pre-wilting was high above 25.1% after 1 days, however that of direct cut silage had 17.6%. And the effluent of wilted silage was decreased with prolonged wilting period, but that of direct cut silage produced effluent of 183 mL/kg. Crude protein and ether extract with wilted silage were decreased, however crude ash was increased with prolonged wilting period. Silage with pre-wilting had higher acid detergent fiber (ADF) and neutral detergent fiber (NDF) contents than control silages, while its non-fiber carbohydrate (NFC) showed the opposite results. Lactic acid and total organic acid were increased with prolonged wilting period. For the palatability of dairy goat, silage with 2 days wilting was highest among silages. The experiment results indicate that wilted sorghum$\times$sudangrass hybrid silage could be recommended as effective method for reducing effluent, increasing pH and forage quality more than direct cut silage. Optimum pre-wilting day of sorghum$\times$sudangrass hybrid silage may be 1 days.

  • PDF

Differential Intracellular Localization of Mitotic Centromere-associated Kinesin (MCAK) During Cell Cycle Progression in Human Jurkat T Cells (인체 Jurkat T 세포에 있어서 세포주기에 따른 MCAK 단백질의 세포 내 위치변화)

  • Jun Do Youn;Rue Seok Woo;Kim Su-Jung;Kim Young Ho
    • Journal of Life Science
    • /
    • v.15 no.2 s.69
    • /
    • pp.253-260
    • /
    • 2005
  • Mitotic centromere-associated kinesin (MCAK), which is a member of the Kin I (internal motor domain) subfamily of kinesin-related proteins, is known to play a role in mitotic segregation of chromosome during M phase of the cell cycle. In the present study, we have produced a rat polyclonal antibody using human MCAK (HsMCAK) expressed in E. coli as the antigen. The antibody specifically recognized the HsMCAK protein (81 kDa), and could detect its nuclear localization in human Jurkat T cells and 293T cells by Western blot analysis. The specific stage of the cell cycle was obtained through blocking by either hydroxyl urea or nocodazole and subsequent releasing from each blocking for 2, 4, and 7 h. While the protein level of HsMCAK reached a maximum level in the S phase with slight decline in the $G_{2}-M$ phase, the electrophoretic mobility shift from $p81^{MCAK}\;to\;p84^{MCAK}$ began to be induced in the late S phase and reached a maximum level in the $G_{2}/M $ phase, and then it disappeared as the cells enter into the $G_{1}$ phase. Immunocytochemical analysis revealed that HsMCAK protein localized to centrosome and nucleus at the interphase, whereas it appeared to localize to the spindle pole, centromere of the condensed mitotic DNA, spindle fiber, or midbody, depending on the specific stage of the M phase. These results demonstrate that a rat polyclonal antibody raised against recombinant HsMCAK expressed in E. coli specifically detects human MCAK, and indicate that the electrophoretic mobility shift from $p81^{MCAK}\;to\;p84^{MCAK}$, which may be associated with its differential intracellular localization during the cell cycle, fluctuates with a maximum level of the shift at the $G_{2}-M$ phase.

Surgical Experiences for Non-ST-segment Elevation Acute Coronary Syndrome (ST분절의 상승을 동반하지 않은 급성 관동맥 증후군의 수술 치험)

  • Yu Song-Hyeon;Lim Sang-Hyun;Chang Byung-Chul;Yoo Kyung-Jong;Hong You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.754-758
    • /
    • 2006
  • Background: Surgical role for acute coronary syndrome has been reduced in recent years due to development of drug eluting stent. We evaluated the surgical results of acute coronary syndrome in our hospital. Material and Method: Between January 2001 and August 2005, 416 patients underwent coronary artery bypass grafting (CABG) under diagnosis of non-ST-elevation acute coronary syndrome (NSTE ACS). Mean age was $61.8{\pm}9.0$ years and 276 (66.3%) patients were male. 324 (77.9%) patients had triple vessel disease and 92 (22.1%) had left main disease at angiographic study. 236 (56.7%) patients had hypertension and 174 (41.8%) had diabetes mellitus. Conventional on-pump CABG was performed in 194 patients (46.6%) and off-pump CABG in 222 (53.4%). Total arterial revascularization with no touch technique was done in 97 patients (23.3%). The number of total distal anastomosis was 1,306 and the number per patient was $3.21{\pm}1.71$. Result: Surgical mortality rate was 1.0% (4 patients) and postoperative complication rate was 15.6% (65 patients). Graft patency was checked at mean $3.7{\pm}7.6$ months (from 1 to 37 months) postoperatively with multi-directional computed tomography in 152 patients. Left internal mammary artery was patent in 95.3%, right internal mammary artery in 98.1%, radial artery in 92.2% and saphenous vein in 89.0%. Conclusion: The surgical treatment of NSTE ACS showed relatively low mortality rate and good graft patency rate. Further study is needed to compare the long term results with drug eluting stent.

Clinical Analysis of the Early Result of Coronary Artery bypass Graft (관상동맥 우회로술 154예이 조기 임상 결과)

  • Song Chang Min;Ahn Jae Bum;Kim Woo Shik;Shin Yong Chul;Yoo Hwan Kook;Kim Byung Yul;Kim In-Sub
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.476-482
    • /
    • 2005
  • Recently, coronary artery obstructive disease and coronary artery bypass graft surgery have increased, and the operative result has been improved. We reviewed 154 cases of coronary artery bypass graft surgery from Jan. 1985 to Jun. 2004. Material and Method: We reviewed 148 patients, 154 cases of coronary artery bypass surgery from Jan. 1985 to Jun. 2004. This investigation is designed to illustrate the preoperative diagnosis, severity of disease, operative method, the kind of used bypass graft used, number of distal anasomosis, associated surgery, and postoperative morbidity and mortality. Result: There were 84 males, 64 females and the average age was $58.9\pm8.3$ years old. Preoperative clinical diagnosis were unstable angina in 97 cases $(63.0\%)$, stable angina in 31 cases $(20.1\%)$, acute myocardial infarction in 12 cases $(7.8\%)$ and postinfartion angina in 14 cases $(9.1\%)$. Preoperative angiographic diagnosis were three-vessel disease in 68 $(44.2\%)$, two-vessel disease in 39 $(25.3\%)$, one-vessel disease in 35$(22.7\%)$, and left main disease in 12$(7.8\%)$ cases. There were 78 cases of on-pump coronary artery bypass graft surgery and 76 cases of off-pump coronary artery bypass graft surgery. The total distal anastomoses number was 319, mean number of anastomoses was $2.06\pm0.96$. There were 10 concomitant procedures. Postoperative intra-aortic balloon pump was used in 21$(13.6\%)$ cases, but only 4 cases were used at off-pump coronary artery bypass surgery. Total early mortality was $7.8\%$. The mortality was decreased as $4.5\%$ from Jan. 2001 to Jun. 2004. Post operative complication was perioperative yocardial infarction in 9cases$(5.8\%)$, low cardiac output syndrome in 17 cases$(11\%)$, and arrhythmia in 30 cases$(19.5\%)$ cases. Conclusion: Since 1985, The result of coronary artery bypass graft surgery has been improved because of more refined technique, use of off-pump coronary artery bypass surgery, use of internal thoracic artery and radial artery as bypass graft. We should study the long-term follow up more for better operative results.

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.