• 제목/요약/키워드: OES(optical emission spectroscopy)

검색결과 208건 처리시간 0.032초

OES를 이용한 SBT 박막의 식각 특성 연구 (The Study of Etching Characteristic in $SrBi_2$$Ta_2$$O_9$ Thin Film by Optical Emission Spectroscopy)

  • 신성욱;김창일;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.185-189
    • /
    • 2001
  • In this paper, since the research on the etching of SrBi$_2$Ta$_2$$O_{9}$(SBT) thin film was few (specially Cl$_2$-base) we had studied the surface reaction of SBT thin films. We have used the OES(optical emission spectroscopy) in high density plasma etching as a function of RF power, dc bias voltage, and Cl$_2$/(Cl$_2$+Ar) gas mixing ratio. It had been found that the etch rate of SBT thin films appeared to be more affected by the physical sputtering between Ar ions and surface of the SBT compared to the chemical reaction. The change of Cl radical density that was measured by the OES as a function of gas combination showed the change of the etch rate of SBT thin films. Therefore, the chemical reactions between Cl radical in plasma and components of the SBT enhanced to increase the etch rates SBT thin films. These results were confirmed by XPS(x-ray photoelectron spectroscopy) analysis.s.

  • PDF

SiON 박막의 광학적 특성에 대한 연구 (The study of SiON thin film for optical properlies)

  • 김도형;임기주;김기현;김현석;김상식;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2001
  • We studied optical properties of SiON thin-film in the applications of optical waveguide. SiON thin-film was grown in 300$^{\circ}C$ by PECVD(plasma enhanced chemical vapor deposition) system. The change of SiON thin-film composition and refractive Index was studied as a function of varying NH$_3$ gas flow rate. As NH$_3$ gas flow rate was increased, Quantity of N and refractive index were increased at the same time. By the results, we could form the SiON thin-film to use of a waveguide with refractive index of 1.6. We analyzed the conditions of the thin-film with FTIR(fourier transform infrared) and OES(optical emission spectroscopy). N-H bonding(3390cm$\^$-1/) can be removed by thermal annealing. And we could observe the SiH bonding state and quantity by OES analysis in SiH$_4$

  • PDF

수평형 유도결합 플라즈마를 이용한 그래핀의 질소 도핑에 대한 연구 (A Study on Nitrogen Doping of Graphene Based on Optical Diagnosis of Horizontal Inductively Coupled Plasma)

  • 조성일;정구환
    • 한국표면공학회지
    • /
    • 제54권6호
    • /
    • pp.348-356
    • /
    • 2021
  • In this study, optical diagnosis of plasma was performed for nitrogen doping in graphene using a horizontal inductively coupled plasma (ICP) system. Graphene was prepared by mechanical exfoliation and the ICP system using nitrogen gas was ignited for plasma-induced and defect-suppressed nitrogen doping. In order to derive the optimum condition for the doping, plasma power, working pressure, and treatment time were changed. Optical emission spectroscopy (OES) was used as plasma diagnosis method. The Boltzmann plot method was adopted to estimate the electron excitation temperature using obtained OES spectra. Ar ion peaks were interpreted as a reference peak. As a result, the change in the concentration of nitrogen active species and electron excitation temperature depending on process parameters were confirmed. Doping characteristics of graphene were quantitatively evaluated by comparison of intensity ratio of graphite (G)-band to 2-D band, peak position, and shape of G-band in Raman profiles. X-ray photoelectron spectroscopy also revealed the nitrogen doping in graphene.

Data Qualification of Optical Emission Spectroscopy Spectra in Resist/Nitride/Oxide Etch: Coupon vs. Whole Wafer Etching

  • Kang, Dong-Hyun;Pak, Soo-Kyung;Park, George O.;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.433-433
    • /
    • 2012
  • As the requirement in patterning geometry continuously shrinks down, the termination of etch process at the exact time became crucial for the success in nano patterning technology. By virtue of real-time optical emission spectroscopy (OES), etch end point detection (EPD) technique continuously develops; however, it also faced with difficulty in low open ratio etching, typically in self aligned contact (SAC) and one cylinder contact (OCS), because of very small amount of optical emission from by-product gas species in the bulk plasma glow discharge. In developing etching process, one may observe that coupon test is being performed. It consumes costs and time for preparing the patterned sample wafers every test in priority, so the coupon wafer test instead of the whole patterned wafer is beneficial for testing and developing etch process condition. We also can observe that etch open area is varied with the number of coupons on a dummy wafer. However, this can be a misleading in OES study. If the coupon wafer test are monitored using OES, we can conjecture the endpoint by experienced method, but considering by data, the materials for residual area by being etched open area are needed to consider. In this research, we compare and analysis the OES data for coupon wafer test results for monitoring about the conditions that the areas except the patterns on the coupon wafers for real-time process monitoring. In this research, we compared two cases, first one is etching the coupon wafers attached on the carrier wafer that is covered by the photoresist, and other case is etching the coupon wafers on the chuck. For comparing the emission intensity, we chose the four chemical species (SiF2, N2, CO, CN), and for comparing the etched profile, measured by scanning electron microscope (SEM). In addition, we adopted the Dynamic Time Warping (DTW) algorithm for analyzing the chose OES data patterns, and analysis the covariance and coefficient for statistical method. After the result, coupon wafers are over-etched for without carrier wafer groups, while with carrier wafer groups are under-etched. And the CN emission intensity has significant difference compare with OES raw data. Based on these results, it necessary to reasonable analysis of the OES data to adopt the pre-data processing and algorithms, and the result will influence the reliability for relation of coupon wafer test and whole wafer test.

  • PDF

적외선 배경신호 처리를 통한 OES 기반 PECVD공정 모니터링 정확도 개선 (OES based PECVD Process Monitoring Accuracy Improvement by IR Background Signal Subtraction from Emission Signal)

  • 이진영;서석준;김대웅;허민;이재옥;강우석
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.5-9
    • /
    • 2019
  • Optical emission spectroscopy is used to identify chemical species and monitor the changes of process results during the plasma process. However, plasma process monitoring or fault detection by using emission signal variation monitoring is vulnerable to background signal fluctuations. IR heaters are used in semiconductor manufacturing chambers where high temperature uniformity and fast response are required. During the process, the IR lamp output fluctuates to maintain a stable process temperature. This IR signal fluctuation reacts as a background signal fluctuation to the spectrometer. In this research, we evaluate the effect of infrared background signal fluctuation on plasma process monitoring and improve the plasma process monitoring accuracy by using simple infrared background signal subtraction method. The effect of infrared background signal fluctuation on plasma process monitoring was evaluated on $SiO_2$ PECVD process. Comparing the $SiO_2$ film thickness and the measured emission line intensity from the by-product molecules, the effect of infrared background signal on plasma process monitoring and the necessity of background signal subtraction method were confirmed.

Virtual Metrology for predicting $SiO_2$ Etch Rate Using Optical Emission Spectroscopy Data

  • Kim, Boom-Soo;Kang, Tae-Yoon;Chun, Sang-Hyun;Son, Seung-Nam;Hong, Sang-Jeen
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.464-464
    • /
    • 2010
  • A few years ago, for maintaining high stability and production yield of production equipment in a semiconductor fab, on-line monitoring of wafers is required, so that semiconductor manufacturers are investigating a software based process controlling scheme known as virtual metrology (VM). As semiconductor technology develops, the cost of fabrication tool/facility has reached its budget limit, and reducing metrology cost can obviously help to keep semiconductor manufacturing cost. By virtue of prediction, VM enables wafer-level control (or even down to site level), reduces within-lot variability, and increases process capability, $C_{pk}$. In this research, we have practiced VM on $SiO_2$ etch rate with optical emission spectroscopy(OES) data acquired in-situ while the process parameters are simultaneously correlated. To build process model of $SiO_2$ via, we first performed a series of etch runs according to the statistically designed experiment, called design of experiments (DOE). OES data are automatically logged with etch rate, and some OES spectra that correlated with $SiO_2$ etch rate is selected. Once the feature of OES data is selected, the preprocessed OES spectra is then used for in-situ sensor based VM modeling. ICP-RIE using 葰.56MHz, manufactured by Plasmart, Ltd. is employed in this experiment, and single fiber-optic attached for in-situ OES data acquisition. Before applying statistical feature selection, empirical feature selection of OES data is initially performed in order not to fall in a statistical misleading, which causes from random noise or large variation of insignificantly correlated responses with process itself. The accuracy of the proposed VM is still need to be developed in order to successfully replace the existing metrology, but it is no doubt that VM can support engineering decision of "go or not go" in the consecutive processing step.

  • PDF

Neural Network-based Time Series Modeling of Optical Emission Spectroscopy Data for Fault Prediction in Reactive Ion Etching

  • Sang Jeen Hong
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.131-135
    • /
    • 2023
  • Neural network-based time series models called time series neural networks (TSNNs) are trained by the error backpropagation algorithm and used to predict process shifts of parameters such as gas flow, RF power, and chamber pressure in reactive ion etching (RIE). The training data consists of process conditions, as well as principal components (PCs) of optical emission spectroscopy (OES) data collected in-situ. Data are generated during the etching of benzocyclobutene (BCB) in a SF6/O2 plasma. Combinations of baseline and faulty responses for each process parameter are simulated, and a moving average of TSNN predictions successfully identifies process shifts in the recipe parameters for various degrees of faults.

  • PDF

Real-Time Plasma Process Monitoring with Impedance Analysis and Optical Emission Spectroscopy

  • Jang, Hae-Gyu;Kim, Dae-Kyoung;Kim, Hoon-Bae;Han, Sa-Rum;Chae, Hee-Yeop
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.473-473
    • /
    • 2010
  • Plasma is widely used in various commercial etchers and chemical vapor deposition. Unfortunately, real-time plasma process monitoring is still difficult. Some methods of plasma diagnosis is improved, however, it is possible for real-time plasma diagnosis to use non-intrusive probe only. In this research, the object is to investigate the suitability of using impedance analysis and optical emission spectroscopy (OES) for real-time plasma process monitoring. It is assumed that plasma system is a equivalent circuit. Therefore, V-I probe is used for measuring impedance, which can be a new non-intrusive probe for plasma diagnosis. From impedance data, we tried to analyse physical properties of plasma. And OES, the other method of plasma diagnosis, is a typical non-intrusive probe for analyzing chemical properties. The amount of the OES data is typically large, so this poses a difficulty in extracting relevant information. To solve this problem, principal component analysis (PCA) can be used. For fundamental information, Ar plasma and $O_2$ plasma are used in this experiment. This method can be applied to real-time endpoint and fault detections.

  • PDF

The Influence of Radiation Trapping on the Metastable Population Density and Applications to Low-pressure Plasma

  • 이영광;오세진;정진욱
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.245-246
    • /
    • 2011
  • Emission lines ratios were used for diagnostics of and excited level densities in low-temperature plasmas. In this work, an optical emission spectroscopy (OES) was used to determine the electron temperature and metastable level densities in low-pressure inductively coupled plasma. The emission spectroscopy method was based on a simple collisional-radiative model. The selected lines of the Ar(4p to 4s) were influenced by the radiation trapping at relatively high pressures where the plasma become optically thick. To quantify this effect, a pressure dependence factor ${\alpha}$(P) was derived by using corrections for the measured intensities. It was found that the lower metastable level densities were obtained when ${\alpha}$(P) increased with the increasing discharge pressure. The effect of non-Maxwellian electron energy distribution functions (EEDFs) on the metastables was also presented and discussed.

  • PDF

저주파 및 고주파 구동 대기압 플라즈마 젯의 특성 비교

  • 권양원;백은정;엄인섭;조혜민;김선자;정태훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.194.2-194.2
    • /
    • 2016
  • 저주파 (수십 kHz)와 고주파 (13.56 MHz)로 구동되는 대기압 플라즈마 젯을 발생시키고, 인가전압 (혹은 인가전력)과 기체 유량에 따른 대기압 플라즈마의 특성을 비교하였다. 고주파에서 발생된 플라즈마는 저주파의 경우보다 안정적이었으며, 인가전압 (혹은 인가전력)이 증가함에 따라 플라즈마 기체온도는 상승하였고, 고주파 젯의 기체온도는 저주파 젯 보다 높았으나 330 K이하인 것을 확인하였다. Optical Emission Spectroscopy (OES)를 이용하여 저주파와 고주파의 광 방출 특성을 측정하였다. 저주파에서는 $N_2{^+}$ (391.4 nm)의 intensity 증가가 두드러지게 나타났지만 고주파 젯에서는 $N_2$, $N_2{^+}$의 intensity는 감소하였으며, OH, NO, $H_{\alpha}$, O와 같은 활성 산소 종 (Reactive Oxygen Species)이 저주파 젯 보다 높게 측정되었다. Boltzmann plot method를 이용한 분석을 통해 저주파와 고주파 영역에서의 플라즈마 전자 여기 온도를 측정하였다. 또한 자외선 흡수분광법을 이용하여 플라즈마-액체 계면에서의 OH이 입자밀도를 측정하여 OES방법으로 측정한 OH 밀도와 비교하였다. 그리고 화학적 측정법 (terephtalic acid solution)을 이용하여 액체 내의 OH의 농도를 측정하였다.

  • PDF