• Title/Summary/Keyword: ODS

Search Result 443, Processing Time 0.025 seconds

Occupational Dermatoses by Type of Work in Greece

  • Zorba, Eleni;Karpouzis, Antony;Zorbas, Alexandros;Bazas, Theodore;Zorbas, Sam;Alexopoulos, Elias;Zorbas, Ilias;Kouskoukis, Konstantinos;Konstandinidis, Theodoros
    • Safety and Health at Work
    • /
    • v.4 no.3
    • /
    • pp.142-148
    • /
    • 2013
  • Background: To elucidate the relationship between seven occupational dermatoses (ODs) and 20 types of work in Greece. Methods: This was a prevalence epidemiologic study of certain ODs among 4,000 workers employed in 20 types of enterprise, in 104 companies, in 2006-2012, using data from company medical records, questionnaires, occupational medical, and special examinations. The ${\chi}^2$ test was applied to reveal statistically significant relationships between types of enterprises and occurrence of ODs. Results: A high percentage (39.9%) of employees included in the study population suffered from ODs. The highest prevalence rates were noted among hairdressers (of contact dermatitis: 30%), cooks (of contact dermatitis: 29.5%), bitumen workers (of acne: 23.5%), car industry workers (of mechanical injury: 15%), construction workers (of contact urticaria: 29.5%), industrial cleaning workers (of chemical burns: 13%), and farmers (of malignant tumors: 5.5%).We observed several statistical significant correlations between ODs (acute and chronic contact dermatitis, urticaria, mechanical injury, acne, burns, skin cancer) and certain types of enterprises. There was no statistically significant correlation between gender and prevalence of ODs, except for dermatoses caused by mechanical injuries afflicting mainly men [${\chi}^2(1)=13.40$, p < 0.001] and for chronic contact dermatitis [${\chi}^2(1)=5.53$, p=0.019] afflicting mainly women. Conclusion: Prevalence of ODs is high in Greece, contrary to all official reports by the Greek National Institute of Health. There is a need to introduce a nationwide voluntary surveillance system for reporting ODs and to enhance skin protection measures at work.

Correlation between Sasang Constitution and Eight Principle Pattern Identification, Qi-Blood Pattern Identification, Bing-Xie Pattern Identification by using Oriental Diagnosis System (전문가시스템을 활용한 사상체질과 팔강변증, 기혈변증, 병사변증간의 상관관계)

  • Hwang, Kyo Seong;Park, Jun Gwan;Choi, Seong Un;Noh, Yun Hwan;Cho, Young Seuk;Shin, Dong Ha;Kwon, Young Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.6
    • /
    • pp.370-374
    • /
    • 2018
  • Oriental Diagnosis System(ODS) is an artificial intelligence program that utilize entered diagnosis knowledge, determine patient's disease and decide right medicine. The purpose of this study is to find a correlation between pattern Identification in Korean medicine and each sasang types(Tae-Eum and So-Yang) by analyzing ODS diagnosis result. Eventually our study secure availability of using ODS program at clinical training or developing diagnosis program. Subject of this study is 50 patients who was performed Sasang constitution diagnosis (28 patients were Tae-Eum and 22 patients were So-Yang). We analyize patient's diagnosis records by using ODS program and obtained result about pattern Identification. We used SPSS statistics 23 in analyzing the differences of the scores of Eight Principle Pattern Identification, Qi-Blood Pattern Identification, and Bing-xie Pattern Identification in each Sasang types (Tae-Eum, So-Yang). The Heat and Heat-moisture scores were significantly different(p<0.05) and Qi-Blood Pattern Identification scores were not different in each Sasang types(p>0.05). And Weight was significantly different in each Sasang types(p<0.05). It is hard to generalize the result because subject of this study was not enough and had sample speciality(tinnitus patients). However, we explained correlation between pattern Identification in korean medicine and each sasang types based on quantifiable and objective evidence system. it can be used at education of korean medicine and evidence of practice diagnosis. Futhermore, there have been no studies about anaylizing correlation between pattern Identification in Korean medicine and each sasang types using ODS program. So it is worthy of being utilized at clinical evidence data of ODS program.

Fabrication and Characterization of ODS 316L Stainless Steels (산화물 분산강화형 316L 스테인리스강의 제조와 특성 연구)

  • Kim, Min-Ho;Ryu, Ho-Jin;Kim, Sung-Soo;Han, Chang-Hee;Jang, Jin-Sung;Kwon, Oh-Jong
    • Journal of Powder Materials
    • /
    • v.16 no.2
    • /
    • pp.122-130
    • /
    • 2009
  • Austenitic oxide-dispersion-strengthened (ODS) stainless steel was fabricated using a wet mixing process without a mechanical milling in order to reduce contaminations of impurities during their fabrication process. Solution of yttrium nitrate was dried after a wet mixing with 316L stainless steel powder. Carbon and oxygen contents were effectively reduced by this wet processing. Microstructural analysis showed that coarse yttrium silicates of about 150 nm were formed in austenitic ODS steels with a silicon content of about 0.8 wt%. Wet-processed austenitic ODS steel without silicon showed higher yield strength by the presence of finer oxide of about 20 nm.

Fabrication and Tensile Properties of Alloy 617 base ODS Alloy (Alloy 617계 산화물 분산강화(ODS) 합금의 제조와 인장특성)

  • Min, Hyoung-Kee;Kang, Suk-Hoon;Kim, Tae-Kyu;Han, Chang-Hee;Kim, Do-Hyang;Jang, Jin-Sung
    • Journal of Powder Materials
    • /
    • v.18 no.6
    • /
    • pp.482-487
    • /
    • 2011
  • Alloy 617, Ni-22Cr-12Co-9Mo base oxide dispersion strengthened alloy was fabricated by using mechanical alloying, hot isostatic pressing and hot rolling. Uniaxial tensile tests were performed at room temperature and at $700^{\circ}C$. Compared with the conventional Alloy 617, ODS alloy showed much higher yield strength and tensile strength, but lower elongation. Fracture surfaces of the tensile tested specimens were investigated in order to find out the mechanism of fracture mode at each test temperature. Grain adjustment during tensile deformation was analyzed by electron backscattered diffraction mapping, inverse pole figures and TEM observation.

A Study on the Torsional Vibration of propulsion Shafting System with Controllable Pitch Propeller (가변익 프로펠러를 갖는 추진축계의 비틀림진동에 관한 연구)

  • 이돈출
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.626-634
    • /
    • 1998
  • Controllable pitch propeller(CPP) is usually adopted for easy and effective engine controls of a ship in a port. Unfortunately the torsional vibration may occur by a certain variation of engine torque and the major resonance peak may exist within the maximum continuous rating(MCR) In these cases an additional stress concentration on the oil passages such as longitudinal slots notches and circular holes of an oil distributor shaft(ODS) occurs by the torsional vibration of the CPP shaft. In this paper an analysis for the fatigue limit of an ODS system of the 5S70MC engine in a crude oil carrier is done by applying FEM and empirical formulas. Furthermore the additional stress on the ODS is investigated by analyzing the torsional vibration of the shaft system and a control method in which a tuning damper is adopted is introduced in the case of the additional stress exceeds the fatigue limit. The validity of analysis method is verified by comparing the results acquired by an actual measurement of the vibratory torque for the above ODS

  • PDF

Microstructure and Mechanical Properties of ODS Ferrite Produced by Reactive Milling for the MSR Suppression (MSR (Mechanically induced Self-sustaining Reaction)이 억제된 반응성 밀링에 의해 제조된 분산강화 페라이트의 미세조직과 기계적 특성)

  • Hwang, Seung J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.26 no.6
    • /
    • pp.279-287
    • /
    • 2013
  • Oxide Dispersion Strengthened (ODS) Fe with $Al_2O_3$ dispersoid was successfully produced by reactive milling with a mixture of Fe, $Fe_3O_4$ (Magnetite), $Fe_2O_3$ (Hematite) and Al reactants at cryogenic temperature. The milled powders were consolidated by Vacuum Hot Press (HP) at 1323 K, and the consolidated materials were characterized by Transmission Electron Microscopy (TEM), Scanning Transmission Electron Microscopy (STEM), and Energy Dispersive Spectroscopy (EDS); the yield strength and the hardness of the consolidated materials were determined by compressive test and Vickers hardness test at room temperature. The grain size of the materials was estimated by X-ray Diffraction technique using the scherrer's formula. The TEM observations showed that the microstructure was comprised with a mixture of nanocrystalline Fe matrix and $Al_2O_3$ nano-dispersoids with a bimodal size distribution; the 0.2% off-set yield strength of the materials was as high as $758{\pm}29$ MPa and the Vickers hardness was $358{\pm}2$. The effect of the cryogenic milling and addition of extra Fe powder was discussed on the suppression of MSR (Mechanically induced Self-sustaining Reaction) for the desired microstructural evolution of ODS alloys.

Mechanical Properties of ODS Fe Alloys Produced by Mechano-Chemical Cryogenic Milling (극저온 기계화학적 밀링(Mechano-Chemical Milling)에 의해 제조된 ODS Fe 합금의 기계적 특성)

  • Hahn, Sung-In;Hong, Young-Hwan;Hwang, Seung-Joon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.3
    • /
    • pp.138-145
    • /
    • 2012
  • An ${\alpha}$-Ferrite (Fe) powder dispersed with 4 vol.% of $Al_2O_3$ was successfully produced by a simple miling at 210 K with a mixture of $Fe_2O_3$, Fe and Al ingredient powders, followed by 2 step high temperature consolidation: Hot Pressing (HP) at 1323 K and then Hot Isostatic Pressing at 1423 K. The microstructure of the consolidated material was characterized by standard metallographic techniques such as XRD (X-ray Diffraction), TEM and STEM-EDS. The results of STEM-EDS analysis showed that the HIPed materials comprised a mixture of pure Fe matrix with a grain size of ~20 nm and $Al_2O_3$ with a bimodal size distribution of extremely fine (~5 nm) and medium size dispersoids (~20 nm). The mechanical properties of the consolidated materials were characterized by compressive test and micro Vickers hardness test at room temperature. The results showed that the yield strength of the ODS (Oxide Dispersion Strengthened) Fe alloy are as much as $674{\pm}39$ MPa and the improvement of the yield strength is attributed to the presence of the fine $Al_2O_3$ dispersoid.