• Title/Summary/Keyword: O-Lot

Search Result 380, Processing Time 0.027 seconds

A Study on the Remicon B/P Application and Properties of High Strength Concrete using Crushed Sand (부순모래를 사용한 고강도콘크리트의 특성 및 레미콘 B/P 적용에 관한 연구)

  • Choi, Se-Jin;Lee, Seong-Yeon;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.57-62
    • /
    • 2007
  • Generally, the strength of concrete depends on factors of materials, mix proportions, compaction, manufacturing methods and curing and so on. And recently, it has increased the using of crushed sand for concrete due to the exhaustion of good natural aggregate. In case of Korea, in 2004, the using ratio of crushed sand occupies about 28% of whole fine aggregate. This is an experimental study to compare and analyze the influence of W/B ratio and replacement ratio of crushed sand on the fluidity and compressive strength of high strength concrete. For this purpose, the mix proportions of concrete according to the W/B (31.5, 27.5, 23.5%) and replacement ratio of crushed sand (0, 20, 40%) was selected. And then air content, slump-flow, a-lot, compressive strength test were performed.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

Study on Comparison of an I/O Program Execution Time to Intel Series μPs : 8085, 8086, 8051 and 80386 (마이크로프로세서 I/O 프로그램 실행시간 비교 연구 : 8085, 8086, 8051 및 80386)

  • Lee, Young-Wook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.59-65
    • /
    • 2013
  • Microprocessors of 8 to 16 bits have become the first step of today's computer development with excellent capability and a lot of those are still used in the educational spots. In this study, execution times of Intel series microprocessors(${\mu}ps$) available to microprocessor systems of 8 to 32 bits are obtained and compared by I/O programs. The compared result showed that execution time related to the instruction cycles of 8 bit 8051 was longer than that of 8 bit 8051 and of 16 bit 8086 by a lot of number of clocks in cases of clock frequencies at 4 MHz and at 12 MHz. In cases of really many using ${\mu}p$ clock frequencies, it showed that execution times of instructions have become faster by the order of 8085, 8086, 8051 and 80386. It can be helped to interface with ${\mu}ps$ for real time control through comparing with execution times of I/O programs by mainly many usable Intel series ${\mu}ps$ in our nation.

A Study on Fluidity ability, Filling ability Properties of High Fluidity Concrete with Illite Powder (일라이트 미분말을 혼입한 고유동 콘크리트의 유동성 및 충전성에 관한 연구)

  • Lee, Dong-Un;Lee, Maeng-Gyo;Park, Hyun-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8363-8369
    • /
    • 2015
  • This study is to be investigate properties of workability, compacting and compressive strength replaced by the illite powder in high fluidity concrete. For this purpose, illite powder has replaced the binder of high fluidity concrete of 5%, 10%, 15%, 20%. After concrete mixing, slump flow test, reach time slump flow 500mm, O-lot test were conducted on fresh high fluidity concrete. And compressive strength was determined 28 days for the hardened high fluidity concrete specimens. According to the test results, the workability, filling height of high fluidity concrete were increased in 10% replacement of illite powder. Furthermore, the compressive strength of high fluidity concrete was increased in 10% replacement of illite powder.. It was possible to confirm that optimal mixture ratio of illite powder seems to exist, and it is shown to be 10% according to our experimental results.

A study on properties of ultra high strength concrete of above 100MPa - fluidity and rheology properties (100MPa급 이상의 초고강도 콘크리트의 특성에 관한 연구 - 유동성 및 rheology 특성)

  • Seo, Il;Lee, Jin-Woo;Park, Hee-Gon;Bae, Yeon-Ki;Cho, Sung-Hyun;Lee, Han-Seung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.317-320
    • /
    • 2008
  • In recent year, the ultra high strength concrete has highly increased and been used in many parts of the world. However, the viscosity of the ultra high strength concrete is high because of a low water to binder ratio (w/b). So that in this pater, the shear stress and the shear strain rate are directly measured by the viscometer in order to estimate the rheological properties of the ultra high strength concrete and a linear regression analysis was carried out to determine the plastic viscosity and the yield stress as slope. According to the test results, the yield stress and plastic viscosity are correlated to slump-flow, V-funnel flow time, O-lot flow time

  • PDF

Mobile Client System Design & Implementation of J2ME Base for Location Information (위치정보를 위한 J2ME기반의 모바일 클라이언트 시스템 설계 및 구현)

  • 이창희;전형준;나극환
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.10
    • /
    • pp.547-558
    • /
    • 2003
  • This paper is a parking management system which uses mobile terminal equipment by the client. From the Web server, the client will be served about the information concerned with the location o( parking lot, parking time, and payment after accessing the parking management web site. After the sensor which is set in the parking lot perceives the information about the client's car, it will inform the client of the parking place. This system is designed to control the large and complex parking lot and serves a very convenient interface to the user.

  • PDF

Note : Lot-Sizing Problems with Backlogging for Batch Production (추후조달 배치생산을 위한 로트-사이징 문제에 대한 소고)

  • Kang, Jangha;Kim, Nam K.;Choi, Sungyong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.4
    • /
    • pp.424-427
    • /
    • 2014
  • In this paper, we consider a production system in which the items are produced by batch. For a production planning of the system, we formulate a lot-sizing problem in which each production should be a multiple of a given unit batch and backlogging is allowed. We propose an optimal dynamic programming algorithm for the plan whose complexity is $O(T^2)$ where T is the maximum number of periods in a plan.

Properties of $TiO_2-V_2O_5$ Ceramics Prepared by Sol-Gel Method (솔젤법으로 제작한 $TiO_2-V_2O_5$ 세라믹스의 물성)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1255-1260
    • /
    • 2007
  • [ $TiO_2-V_2O_5$ ] sol was prepared using sol-gel method. Sol changed to gel with hydrolysis and polymerization. DTA properties of gel powder had endothermic reaction due to evaporation of propanol about $80^{\circ}C$, had exothermic reaction due to combustion of propanol about $230^{\circ}C$ and had exothermic reaction due to combustion of alkyl group about $350^{\circ}C$. Crystalline properties of gel powder retained amorphous phase at $50^{\circ}C$, retained anatase phase from $400^{\circ}C\;to\;600^{\circ}C$ and had all rutile phase over $700^{\circ}C$ at 0.01mole $V_2O_5$ additive. The capacitance of thin films increased with increasing heat treatment temperature and thin films had best properties at $700^{\circ}C$. The capacitance of thin films increased a lot with decreasing measurement frequency.

Corrosion Resistance of SPCC, SPFC590, SPFC780 Steel by Organic/Inorganic Hybrid Solution (Case of different SiO2 polysilicate under a constant melamin) (유/무기하이브리드 용액에 의한 SPCC, SPFC590, SPFC780 강판의 내식성 (일정한 멜라민에서 SiO2 polysilicate 양이 다른 경우))

  • Nam, Ki-Woo;Jeong, Hee-Rok;Lee, Kwang-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.5-13
    • /
    • 2017
  • This study has developed an organic/inorganic hybrid solution according to amount of $SiO_2$ polysilicate, and the amount of melamine is constant. The three types of cold rolled steel were evaluated a corrosion resistance properties by using these solutions. $US_3M_3$ and $US_{11}M_3$ solutions were generate a lot of corrosion. $US_7M_3$ solution was excellent in corrosion resistance, regardless of the steel type. The appearance of coating by $US_3M_3$ and $US_{11}M_3$ solutions were bumpy surface, and were a lot of fine defects. $US_7M_3$ solution was made a sophisticated molecular cross-linking structure inside the coating, it was a slick surface. Other characteristics are exhibited the excellent property for all solutions.

The Properties of Underwater-Hardening Epoxy Mortar Used the Rapidly Cooled Steel Slag (RCSS) (급냉 제강슬래그를 사용한 수중 경화형 에폭시 모르타르의 특성)

  • Kim, Jin-Man;Kwak, Eun-Gu;Bae, Kee-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.549-555
    • /
    • 2007
  • Although blast furnace slag has been widely used in concrete as a cementitious admixture or aggregate for many years, the slowly cooled steel slag is not used in concrete but mainly in road. Its use in concrete operates problem such as the lack of volume stability due to high free CaO content, which can be potentially hazardous in concrete. However, the rapidly cooled steel slag by atomization has a low free CaO content, a high density, and a spherical shape, so it is expected to use in concrete so much. This paper is to understand the probability that the rapid cooled steel slag can replace the silica sand used as aggregate in the epoxy mortar. We did the experimental study on the properties of the epoxy mortar having various replacement proportion of rapidly cooled steel slag. This study shown that increasing content of the rapidly cooled steel slag in epoxy mortar lead to increase largely the passing time of nozzle by O-lot, compressive strength and flexural strength. However except the flow is almost same level. So we understand that the rapidly cooled steel slag has positive effect on increasing of properties in epoxy mortar.