• 제목/요약/키워드: Numerical Reconstruction

검색결과 249건 처리시간 0.027초

파수영역에서 모멘트 방법을 이용한 새로운 역산란 방법, II : 수치계산 (A New Inverse Scattering Technique Using the Moment Method in the Spectral Domain, II: Numerical Simulation)

  • 이재민;김세윤;나정웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.442-445
    • /
    • 1988
  • In this paper, the reconstruction of complex permittivity distribution on a rectangular cross section of inhomogeneous dielectric cylinders is performed by employing the spectral inverse scattering scheme. Numerical simulations provide the superresolution to the permittivity profiles nearly regardless of the measurement locations of the scattered field and the permittivity distributions on the cross section.

  • PDF

CT 영상 재구성의 공간분해능에 대한 영향 (Influence of CT Reconstruction on Spatial Resolution)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.85-91
    • /
    • 2018
  • 전산화단층촬영기법은 투영 영상을 재구성하여 단면 영상을 획득하는 기법으로 다양한 분야에 적용되고 있다. 재구성된 영상의 공간분해능은 장치, 대상, 재구성 과정에 의존한다. 본 논문은 평행빔 구조에서 투영 영상의 개수 및 검출기의 픽셀 크기가 재구성된 영상의 공간분해능에 미치는 영향을 조사하였다. 재구성 프로그램은 Visual C++로 작성하였으며 단면 영상은 $512{\times}512$ 크기로 하였다. 공간분해능의 특성을 평가하기 위해 수학적 막대 팬텀을 구성하였고, Min-Max 방법을 도입하였다. 재구성에 사용되는 투영의 개수가 작은 경우 허상이 나타났으며 Min-Max도 낮았다. 투영의 개수를 지속적으로 증가시키면 재구성된 영상의 공간분해능을 나타내는 Min-Max는 상향 포화되었다. 검출기의 픽셀 크기를 재구성되는 단면 영상의 픽셀 크기의 50%로 줄이면 영상은 거의 완벽하게 복원되고, 검출기픽셀 크기가 증가할수록 Min-Max는 감소하였다. 본 연구는 CT장치 설계 시 요구되는 공간분해능을 달성하기 위해 필요한 검출기 및 회전 스테이지의 정밀도를 결정하는데 도움이 될 것이다.

Evaluation of Breast Animation Deformity following Pre- and Subpectoral Direct-to-Implant Breast Reconstruction: A Randomized Controlled Trial

  • Dyrberg, Diana L.;Bille, Camilla;Koudahl, Vibeke;Gerke, Oke;Sorensen, Jens A.;Thomsen, Jorn B.
    • Archives of Plastic Surgery
    • /
    • 제49권5호
    • /
    • pp.587-595
    • /
    • 2022
  • Background The incidence of breast animation deformity (BAD) is reported to be substantial after direct-to-implant breast reconstruction with subpectoral implant placement. It has, however, never been examined if BAD can occur following prepectoral implant placement. Our primary aim was to compare the incidence and degree of BAD after direct-to-implant breast reconstruction using either subpectoral or prepectoral implant placement. Secondary aim of this study was to assess and compare the level of pain between sub- and prepectoral reconstructed women. Methods In this randomized controlled trial, patients were allocated to reconstruction by either subpectoral or prepectoral implant placement in accordance with the CONSORT guidelines. The degree of BAD was assessed by the "Nipple, Surrounding skin, Entire breast (NSE)" grading scale 12 months after surgery. The level of postoperative pain was assessed on a numerical pain rating scale. Results We found a significant difference in the degree of BAD favoring patients in the prepectoral group (23.8 vs. 100%, p < 0.0001; mean NSE grading scale score: 0.4 vs. 3.6, p < 0.0001). The subpectoral reconstructed group reported higher levels of pain on the three subsequent days after surgery. No significant difference in pain levels could be found at 3 months postoperatively. Conclusion The incidence and degree of BAD was significantly lower in women reconstructed by prepectoral direct-to-implant breast reconstruction. Unexpectedly, we found mild degrees of BAD in the prepectoral group. When assessing BAD, distortion can be challenging to discern from rippling.

변형 삼각간섭 계를 이용한 거리계측 (Distance Measurement using Modified Triangular Interferometer)

  • 김수길;황보승
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.119-122
    • /
    • 2001
  • We derived the resolution of the modified triangular interferometer and described the analysis about distance measurement using the one. Also, to demonstrate the feasibility of distance measurement using the modified triangular interferometer, the incoherent hologram of a two-point source with depth and its numerical reconstruction were presented.

  • PDF

역산란 문제에서의 비유연성 (Nonuniqueness in Inverse Scattering Problems)

  • 김세윤;라정웅
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1317-1321
    • /
    • 1989
  • The nonuniqueness of solutions to inverse scattering problems for the reconstruction of cross sectional permitivity distributions on dielectric cylinder is illustrated in view of numerical analysis based on the spectral inverse scattering scheme with the moment-method procedures. It is also shown that some additional treatmenents such as multiple measurements, various incidences, etc. are not effective to assure the uniqueness.

  • PDF

마이크로 DMFC 에서 $CO_2$ degassing 과정의 직접 수치 해석 (Direct Numerical Analysis of $CO_2$ degassing process in ${\mu}DMFC$)

  • 신승원;심정익;위완석;조성원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2648-2653
    • /
    • 2007
  • Recently, increasing demand on not only lighter but also extremely mobile battery make micro fuel cell device very attractive alternative. By reducing the size of fuel cell, surface tension becomes dominant factor with minor gravitational effect. Therefore, it is very difficult to detach the $CO_2$ bubble generating on a cathode side in ${\mu}DMFC$ (micro direct methanol fuel cell). The degassing of a $CO_2$ bubble has drawn quite attention especially for ${\mu}DMFC$ due to its considerable effect on overall machine performance. Our attention has been paid to the dynamic behavior of immiscible bubble attached to the one side of the wall on 2D rectangular channel subject to external shear flow. We use Level Contour Reconstruction Method (LCRM) which is simplified version of front tracking method to track the bubble interface motion. Effects of Reynolds number, Weber number, advancing/receding contact angle and property ratio on bubble detachment characteristic has been numerically identified.

  • PDF

고차 정확도 수치기법의 GPU 계산을 통한 효율적인 압축성 유동 해석 (EFFICIENT COMPUTATION OF COMPRESSIBLE FLOW BY HIGHER-ORDER METHOD ACCELERATED USING GPU)

  • 장태규;박진석;김종암
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.52-61
    • /
    • 2014
  • The present paper deals with the efficient computation of higher-order CFD methods for compressible flow using graphics processing units (GPU). The higher-order CFD methods, such as discontinuous Galerkin (DG) methods and correction procedure via reconstruction (CPR) methods, can realize arbitrary higher-order accuracy with compact stencil on unstructured mesh. However, they require much more computational costs compared to the widely used finite volume methods (FVM). Graphics processing unit, consisting of hundreds or thousands small cores, is apt to massive parallel computations of compressible flow based on the higher-order CFD methods and can reduce computational time greatly. Higher-order multi-dimensional limiting process (MLP) is applied for the robust control of numerical oscillations around shock discontinuity and implemented efficiently on GPU. The program is written and optimized in CUDA library offered from NVIDIA. The whole algorithms are implemented to guarantee accurate and efficient computations for parallel programming on shared-memory model of GPU. The extensive numerical experiments validates that the GPU successfully accelerates computing compressible flow using higher-order method.

다공성 칼슘포스파이트에 대한 파괴분석 (Numerical analysis of fracture mechanisms for porous calcium phosphate)

  • 박진홍;배지용;심재범;전인수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1301-1302
    • /
    • 2008
  • In this study, the fracture strength for fracture mechanism porous calcium phosphate made from sintered with ${\beta}$-tricalcium phosphate obtained by wet precipitation procedure is analyzed using finite element method and experiment measurement. First, three $3{\times}3{\times}3mm^3$ and $5{\times}5{\times}5mm^3$ specimens are prepared and tomographic images of one $5{\times}5{\times}5mm^3$ specimen are obtained by micro focus X-ray CT. The compression tests using the specimens are carried out to measure the elastic modulus and fracture strength to analyze the fracture mechanism of porous calcium phosphate specimen. The tomographic images are reconstructed by 3D reconstruction program. The finite elements are directly built up in the reconstructed specimen. The numerical simulation for the compression tests is performed using the element. The mechanism of calcium phosphate of simulation are obtained by the compression tests using there cylindric specimen of height 19.5 mm and diameter 10 mm. From the results, the applicability of porous calcium phosphate is evaluated to care fracture and vacant bone of a patient as the reinforcement material.

  • PDF

콘크리트 구조물의 결함발견을 위한 3차원 초단파 영상처리기법의 개발 (3D Microwave Imaging Technology for Damage Detection of Concrete Structures)

  • 김유진;김용곤
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.98-104
    • /
    • 2003
  • Various nondestructive evaluation (NDE) techniques have been studied to locate steel rebars of dowel, and to detect invisible damage such as voids and cracks inside concrete and debonding between rebars and concrete caused by corrosions and earthquakes. In this study, the aurhors developed 3-dimensional (3D) electromagnetic (EM) imaging technology to detect such damage and to identify exact location of steel rebars of dowel. The authors have developed sub-surface two-dimensional (2D) imaging technique using tomographic antenna array in previous works. In this study, extending the earlier analytical and experimental works on 2D image reconstruction, a 3D microwave imaging system using tomographic antenna array was developed, and multi-frequency technique was applied to improve quality of the reconstructed image and to reduce background noises. This paper presents the analytical expressions of numerical focusing procedures for 3D image reconstruction and numerical simulation to study the resolution of the system and the effectiveness of multi-frequency technique. Also, the design of 4?4 antenna array with switching devices is introduced as a preliminary study for the final design of whole array.