• Title/Summary/Keyword: Number of starts

Search Result 159, Processing Time 0.031 seconds

A Generalized N-Policy for an M/M/1 Queueing System and Its Optimization

  • Bae, Jong-Ho;Kim, Jong-Woo;Lee, Eui-Yong
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.05a
    • /
    • pp.61-66
    • /
    • 2002
  • We consider a generalized N-policy for an M/M/1 queueing system. The idle server starts to work with ordinary service rate when a customer arrives. If the number of customers in the system reaches N, the service rate gets faster and continues until the system becomes empty. Otherwise, the server finishes the busy period with ordinary service rate. We obtain the limiting distribution of the number of customers in the system. After assigning various operating costs to the system, we show that there exists a unique fast service rate minimizing the long-run average cost per unit time.

  • PDF

Analysis on G/M/1 queue with two-stage service policy

  • KIM SUNGGON;KIM JONGWOO;LEE EUI YONG
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.295-300
    • /
    • 2004
  • We consider a G/M/1 queue with two-stage service policy. The server starts to serve with rate of ${\mu}1$ customers per unit time until the number of customers in the system reaches A. At this moment, the service rate is changed to that of ${\mu}2$ customers per unit time and this rate continues until the system is empty. We obtain the stationary distribution of the number of customers in the system.

  • PDF

A Study of the PDCA and CAPD Economic Designs of the $\bar{x}$ Control Chart

  • Sun, Jing;Tsubaki, Michiko;Matsui, Masayuki
    • Industrial Engineering and Management Systems
    • /
    • v.6 no.1
    • /
    • pp.11-21
    • /
    • 2007
  • The PDCA (Plan, Do, Check and Act) cycle is often used in the field of quality management. Recently, business environments have become more competitive, and the due time of products has shortened. In a short production run process, to increase efficiency of management, the necessity for distinguishing the PDCA design that starts with PLAN and the CAPD design that starts with CHECK has been clarified. Starting from Duncan (1956), there have been a number of papers dealing with the economic design of control charts from the viewpoint of production run. Some authors (Gibra, 1971; Ladany and Bedi, 1976; etc.) have studied the economic design for finite-length runs; other authors (Crowder, 1992; Del Castillo and Montgomery, 1996; etc.) have studied the economic design for short runs. However, neither the PDCA nor the CAPD design of control charts has been considered. In this paper, both the PDCA and CAPD designs of the $\bar{\x}$ chart are defined based on Del Castillo and Montgomery's design (1996), and their mathematical formulations are shown. Then from an economic viewpoint, the optimal values of the sample size per each sampling, control limits width, and the sampling interval of the two designs are studied. Finally, by numerically analyzing the relations between the key parameters and the total expected cost per unit time, the comparisons between the two designs are considered in detail.

The Characteristic of the Performance of the Bypass Diode with Composition Change of the String in Si-PV Module (결정질 PV 모듈의 string 구성에 따른 바이패스 다이오드 동작 특성)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2212-2217
    • /
    • 2010
  • Previous studies have been focused on the voltage of Bypass diode and Isc(Short Circuit Current) of the influenced solar cell. The Bypass diode starts working when it gets the reverse applied voltage. Previous studies have only concentrated on Isc of the influenced solar cell and Imp of PV module to explain the bypassing performance. PV module is usually working together with inverter having MPPT(Maximum Power Point Tracking) function for best performance. bypassing point is regulated by MPPT function of inverter. In this paper, simulation results of Bypass diode in PV module have been analyzed to represent the relationship of the bypassing point with the composition of PV module. From the results, the more cells are connected with each string, the earlier bypassing performance happens under the fixed number of strings. As diode groups increase or irradiation decreases, the bypassing performance starts fast.

A Study on Compatibility of Vehicle Using Alternative Fuels (자동차 대체연료의 상호호환성 연구)

  • Lee, Taek-Hee;Kang, Seung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.2
    • /
    • pp.74-81
    • /
    • 2012
  • The purpose of this study provides the theoretical model for protecting the economic and social loss from the current alternative fuel vehicle which is developed without compatibility and senseless one's own through verifying the statistical significant by method of measuring analysis. The market scale of alternative fuel vehicle depends on customer's and station's expectation about the number of potential vehicle users. It is very difficult for vehicle manufacturer to make a decision on the standard alternative fuel vehicle as it might reduce profit and market share. Accordingly, the development of alternative fuel vehicle should have manufacturer confident on the potential profit in the future. Moreover, if we decide to use the non-standard fuel after we started to use the standard fuel, it would take a huge cost comparing with starting to use the standard fuel only. As a result, once one of companies starts to provide the non-standard fuel service, it is getting more difficult to use the standard fuel going forward. Consequently, we may review the possibility of choice on the standard fuel before the vehicle manufacturer starts service with non-standard fuel.

Rock fracturing mechanisms around underground openings

  • Shen, Baotang;Barton, Nick
    • Geomechanics and Engineering
    • /
    • v.16 no.1
    • /
    • pp.35-47
    • /
    • 2018
  • This paper investigates the mechanisms of tunnel spalling and massive tunnel failures using fracture mechanics principles. The study starts with examining the fracture propagation due to tensile and shear failure mechanisms. It was found that, fundamentally, in rock masses with high compressive stresses, tensile fracture propagation is often a stable process which leads to a gradual failure. Shear fracture propagation tends to be an unstable process. Several real case observations of spalling failures and massive shear failures in boreholes, tunnels and underground roadways are shown in the paper. A number of numerical models were used to investigate the fracture mechanisms and extents in the roof/wall of a deep tunnel and in an underground coal mine roadway. The modelling was done using a unique fracture mechanics code FRACOD which simulates explicitly the fracture initiation and propagation process. The study has demonstrated that both tensile and shear fracturing may occur in the vicinity of an underground opening. Shallow spalling in the tunnel wall is believed to be caused by tensile fracturing from extensional strain although no tensile stress exists there. Massive large scale failure however is most likely to be caused by shear fracturing under high compressive stresses. The observation that tunnel spalling often starts when the hoop stress reaches $0.4^*UCS$ has been explained in this paper by using the extension strain criterion. At this uniaxial compressive stress level, the lateral extensional strain is equivalent to the critical strain under uniaxial tension. Scale effect on UCS commonly believed by many is unlikely the dominant factor in this phenomenon.

Application of SPC for Service Quality Control (서비스 품질 관리를 위한 SPC의 적용)

  • Kim Ji Yun;Kang Chang Wook
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.379-386
    • /
    • 2002
  • As the value and relative importance of service industry boosts in modern society, to strengthen competitiveness companies starts to recognize the quality of service as a key component in their business operations. Furthermore, companies that apply the quality of services as their competitive method are concentrating more on the area of quality control. Nevertheless, the previous researches related to this area were more focused on the aspect of measure rather than the control. In this paper, each fractionated customer group in consideration of its characteristics is made in use of estimating the quality of service using the conjoint analysis. The principal variable selective method which a small number of variables is used to control a large number of variables is applied. Hotelling's $T^2$ control chart is applied to administer many relative variables of the quality of service because it is a Multi-item. If abnormal indications appear by adding new data, the method to find and improve variables using MYT decomposition is suggested to apply.

  • PDF

The Effect of Inlet Distorted Flow on Steady and Unsteady Performance of a Centrifugal Compressor (입구 비 균일 유동이 원심압축기의 정상 및 비정상 성능에 미치는 영향)

  • Kang Shin-Hyoung;Park Jae-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.971-978
    • /
    • 2005
  • Effects of inlet distorted flow on performance, stall and surge are experimentally investigated for a high-speed centrifugal compressor. Tested results for the distorted inlet flow cases are compared with the result of the undistorted one. The performance of compressor is slightly deteriorated due to the inlet distortion. The inlet distortion does not affect the number of stall cell and the propagation velocity. It also does not change stall inception flow rate. However, as the distortion increases, stall starts at the higher flow rate for low speed and at the lower flow rate for high speed. For 50,000 rpm stall occurrs as the flow rate decreases, however disappears fur the smaller flow rate. This is due to the interaction of surge and stall. After the stall and surge interact, the number of stall cell decreases.

AERODYNAMIC ANALYSIS OF SUB-ORBITAL RE-ENTRY VEHICLE (저궤도 재진입 비행체의 공력해석)

  • Kim, C.W.;Lee, Y.G.;Lee, D.S.
    • Journal of computational fluids engineering
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • For Aerodynamic analysis of vehicle at altitude, 100km, the validity of governing equations based on continuum model, was reviewed. Also, as the preliminary study for the sub-orbital space plane development, a candidate geometry was suggested and computational fluid dynamic(CFD) analysis was performed for various angles of attack in subsonic and supersonic flow regimes to analyze the aerodynamic characteristics and performance. The inviscid flow analyses showed that the stall starts at angle of attack above $20^{\circ}$, the maximum drag is generated at angle of attack, $87^{\circ}$ and the maximum lift to drag ratio is about 8 in subsonic flow. In supersonic, the stall angle is about $40^{\circ}$ and the maximum drag is generated at angle of attack, $90^{\circ}$. Also, mach number distribution of re-entry vehicle was computed versus altitudes.

A Fast Converged Solution for Power Allocation of OFDMA System

  • Hwang, Sungho;Cho, Ho-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.721-725
    • /
    • 2014
  • In this paper, we propose a fast adaptive power allocation method for an orthogonal frequency division multiple access (OFDMA) system that employs an adaptive modulation and coding (AMC) scheme. The proposed scheme aims to reduce the calculation complexity of greedy adaptive power allocation (APA), which is known as the optimal algorithm for maximizing the utility argument of power. Unlike greedy APA, which starts power allocation from "0", the proposed algorithm initially allocates a certain level of power determined by the water-filling scheme. We theoretically demonstrate that the proposed algorithm has almost the same capability of maximizing the utility argument as the greedy APA while reducing the number of operations by 2M, where M is the number of AMC levels.