Dynamic Response Analysis of Composite H-type Cross-section Beams (복합재료 H-형 단면 보의 동적응답 해석)

  • Kim, Sung-Kyun;Song, Oh-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.583-592
    • /
    • 2010
  • Equations of motion of thin-walled composite H-type cross-section beams exposed to concentrated harmonic and non-harmonic time-dependent external excitations, incorporating a number of nonclassical effects of transverse shear, primary and secondary warping, and anisotropy of constituent materials are derived. The forced vibration response characteristics of a composite H-type cross-section beam exhibiting the circumferentially asymmetric stiffness(CAS) configuration are exploited in connection with the structural bending-torsion coupling resulting from directional properties of fiber reinforced composite materials.

Damage Detection Method for Bridge Structures Using Hilbert-Huang Transform Technique (Hilbert-Huang Transform을 이용한 교량구조물의 손상추정기법)

  • 윤정방;장신애;심성한;이종재
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.453-458
    • /
    • 2002
  • A recently developed Hilbert-Huang transform (HHT) technique is applied to the detection of the damage locations of bridge structures. The HHT may be used to identify the locations of damages which exhibit nonlinear and non-stationary behavior, since the instantaneous frequency characteristics of the measured signal can be analyzed by the HHT. Numerical simulations were conducted on two bridge systems with damages using controlled excitations with sweeping frequency. Nonlinear plastic model using a gap element is employed to model the behavior of the cracked elements in the numerical simulations. The results indicate that the HHT method can reasonably identify the damage locations based on a limited number of acceleration sensors. Experimental study has been 실so carried out on a steel frame to confirm the applicability of the HHT to detect a structural connection with loosened bolts.

  • PDF

Characteristics of sloshing load and flow inside a tank with cylinder structures (실린더 구조물을 설치한 탱크 내부의 슬로싱 하중과 유동 특성)

  • Ki Jong Kim;Hyun-Duk Seo;Daegyoum Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.31-39
    • /
    • 2023
  • Sloshing of the fluid having a free surface produces an impact force on a tank wall subjected to external excitation. This paper investigates the effect of cylindrical structures in a rectangular sloshing tank under translational harmonic excitations. By varying the number of installed cylinders in the tank, the characteristics of the free-surface deformation is experimentally observed, and the peak pressure on the tank wall is extracted by threshold values. To predict the peak pressure, the numerical simulation is also conducted using smoothed particle hydrodynamics (SPH), and the peak values are compared with the experimental results. Furthermore, pressure and velocity fields in the tank and free-surface shape are analyzed at the moment of impact.

A Study on the Error Characteristics in Response Spectrum Analysis (응답스펙트럼해석의 오차특성에 관한 연구)

  • 최형철;배익주;강병도;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.35-42
    • /
    • 1998
  • Response spectrum analysis method(RSA) rather than time history analysis method(THA) continues to e used by the profession for evaluating maximum dynamic responses of structures subjected to earthquake excitations. Nevertheless, this simple and practical method can cause significant errors in some cases with unproper modal combination method and so on. To obtain more exact responses based n RSA many studies have been carried out considering displacement of top story, base shear and overturning moment. The purpose of this study is to verify error characteristics in RSA with respect to various responses including displacement shear force and overturning moment of each story. It's shown that RSA appears to yield underestimated responses when compared to THA calculations. Also, errors involved in RSA computations grow with an increase in total number of stories.

  • PDF

Construction stage effect on the dynamic characteristics of RC frame using operational modal analysis

  • Arslan, Mehmet Emin;Durmus, Ahmet
    • Computers and Concrete
    • /
    • v.12 no.1
    • /
    • pp.79-90
    • /
    • 2013
  • In this study, dynamic characteristics such as natural frequencies, mode shapes and damping ratios of RC frame is determined for different construction stages using Operational Modal Analyses method under ambient vibration. Full scaled, one bay and one story RC frames are selected as an application for different construction stages such as plane, brick in-filled and brick in-filled with plaster. The RC frame is vibrated by natural excitations with small impact effects and the response signals are measured using sensitive accelerometers during ambient vibration tests. Measurement time-frequency span and effective mode number are determined by considering similar studies in literature. Sensitive seismic accelerometers are used to collect signals obtained from the experimental tests. To obtain experimental dynamic characteristics, output-only system identification technique is employed namely; Enhanced Frequency Domain Decomposition technique in the frequency domain. It is demonstrated that the ambient vibration measurements are enough to identify the most significant modes of RC frames.

A study on Self-excitation in Laminar Lifted Propane Coflow-Jet Flames Diluted with Nitrogen (질소로 희석된 프로판 층류 동축류 제트화염에서의 화염진동에 관한 실험적 연구)

  • Lee, Won June;Park, Jeong;Kwon, Oh Boong;Yun, Jin Han;Keel, Sang In;Kim, Tae Hyung;Kim, Young Ju
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.19-22
    • /
    • 2012
  • Experimental study in coflow jet flames has been conducted to investigate effects of adding Helium to coflowing air-side in self-excitation. The Differences between buoyancy-driven and diffusive-thermal self-excitations with the same order of O(1.0 Hz) in self-excitation are explored and discussed in laminar coflow jet flames.

  • PDF

Optimal reduction from an initial sensor deployment along the deck of a cable-stayed bridge

  • Casciati, F.;Casciati, S.;Elia, L.;Faravelli, L.
    • Smart Structures and Systems
    • /
    • v.17 no.3
    • /
    • pp.523-539
    • /
    • 2016
  • The ambient vibration measurement is an output-data-only dynamic testing where natural excitations are represented, for instance, by winds and typhoons. The modal identification involving output-only measurements requires the use of specific modal identification techniques. This paper presents the application of a reliable method (the Stochastic Subspace Identification - SSI) implemented in a general purpose software. As a criterion toward the robustness of identified modes, a bio-inspired optimization algorithm, with a highly nonlinear objective function, is introduced in order to find the optimal deployment of a reduced number of sensors across a large civil engineering structure for the validation of its modal identification. The Ting Kau Bridge (TKB), one of the longest cable-stayed bridges situated in Hong Kong, is chosen as a case study. The results show that the proposed method catches eigenvalues and eigenvectors even for a reduced number of sensors, without any significant loss of accuracy.

Probabilistic structural damage detection approaches based on structural dynamic response moments

  • Lei, Ying;Yang, Ning;Xia, Dandan
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.207-217
    • /
    • 2017
  • Because of the inevitable uncertainties such as structural parameters, external excitations and measurement noises, the effects of uncertainties should be taken into consideration in structural damage detection. In this paper, two probabilistic structural damage detection approaches are proposed to account for the underlying uncertainties in structural parameters and external excitation. The first approach adopts the statistical moment-based structural damage detection (SMBDD) algorithm together with the sensitivity analysis of the damage vector to the uncertain parameters. The approach takes the advantage of the strength SMBDD, so it is robust to measurement noise. However, it requests the number of measured responses is not less than that of unknown structural parameters. To reduce the number of measurements requested by the SMBDD algorithm, another probabilistic structural damage detection approach is proposed. It is based on the integration of structural damage detection using temporal moments in each time segment of measured response time history with the sensitivity analysis of the damage vector to the uncertain parameters. In both approaches, probability distribution of damage vector is estimated from those of uncertain parameters based on stochastic finite element model updating and probabilistic propagation. By comparing the two probability distribution characteristics for the undamaged and damaged models, probability of damage existence and damage extent at structural element level can be detected. Some numerical examples are used to demonstrate the performances of the two proposed approaches, respectively.

Seismic performance evaluation of a steel slit damper for retrofit of structures on soft soil

  • Mahammad Seddiq Eskandari Nasab;Jinkoo Kim;Tae-Sang Ahn
    • Steel and Composite Structures
    • /
    • v.51 no.1
    • /
    • pp.93-101
    • /
    • 2024
  • This paper presents an experimental and analytical study on a steel slit damper designed as an energy dissipative device for earthquake protection of structures considering soil-structure interaction. The steel slit damper is made of a steel plate with a number of slits cut out of it. The slit damper has an advantage as a seismic energy dissipation device in that the stiffness and the yield force of the damper can be easily controlled by changing the number and size of the vertical strips. Cyclic loading tests of the slit damper are carried out to verify its energy dissipation capability, and an analytical model is developed validated based on the test results. The seismic performance of a case study building is then assessed using nonlinear dynamic analysis with and without soil-structure interaction. The soil-structure system turns out to show larger seismic responses and thus seismic retrofit is required to satisfy a predefined performance limit state. The developed slit dampers are employed as a seismic energy dissipation device for retrofitting the case study structure taking into account the soil-structure interaction. The seismic performance evaluation of the model structure shows that the device works stably and dissipates significant amount of seismic energy during earthquake excitations, and is effective in lowering the seismic response of structures standing on soft soil.

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.