• 제목/요약/키워드: Number Of Ventilation

Search Result 337, Processing Time 0.03 seconds

A numerical study on effects of drag coefficient of vehicle on jet fans in case of fire in road tunnels (도로터널 화재시 차량의 항력계수가 제연용 제연팬에 미치는 영향에 대한 해석적 연구)

  • Yoo, Yong-Ho;Yoo, Ji-Oh;Kim, Hyo Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.553-560
    • /
    • 2014
  • The road tunnel install a vent for the purpose of ventilation and smoke control. Ventilation equipment capacity(number of jet fans) depends on from the condition that of the pressure and ventilation resistance. Pressure and the resistance under operating vehicle have affected on the drag coefficient. The drag coefficient of the tunnel have affected by the blockage effect and slipstream effects. However, when calculating the ventilation fan, are not properly consider taking into account such effects. Therefore, ventilation force may have been slightly overestimated. This paper describes the drag coefficient through a numerical analysis to calculate the equivalent resistance area that reflects the vehicle distance, and examined the equivalent resistance area. The ventilation coefficient corresponding to the result heavy vehicle mixing ratio of the present study was not clear. Equivalent resistance area had reduced by about 86% compared to the road design handbook current standards. Also it had analyzed and reduced to 62.2% compared to Korea Highway Corporation ventilation design criteria ratio, which is the old standard.

Energy cost of loads carried on the hands, head, or feet (짐나르기의 에너지 소요량)

  • Hwang, Dai-Yun;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.29-40
    • /
    • 1971
  • Oxygen consumption, pulmonary ventilation, heart rate, and breathing frequency were measured on 8 men walking on a treadmill carrying load of 9 kg on hand, back, or head. Besides measurements were made on subjects carrying loads of 2.6 kg each on both feet. The speed of level walking was 4, 5, and 5.5km/hr and a fixed speed off km/hr with grades of 0, 3, 6, and 9%. Comparisons were made between free walking without load and walking with various types of loads. The following results were obtained. 1. In level or uphill walking the changes in oxygen consumption, pulmonary ventilation, breathing frequency and heart rate were smallest in back load walking, and largest in hand load walking. The method of back load was most efficient and hand load was the least efficient. The energy cost in head load walking was smaller than that of in hand load walking. It was assumed that foot load costed more energy than hand load. 2. In level walking the measured parameters increased abruptly at the speed of 5.5 km/hr. Oxygen consumption in a free walking at 4 km/hr was 11.4ml/kg b.wt., and 13.1 ml/kg b.wt. 5.5 km/hr, and in a hand load walking at 4 km/hr was 13.9, and 18.8 ml/kg b. wt. at 5.5 km/hr. 3. In uphill walking oxygen consumption and other parameters increased abruptly at the grade of 6%. Oxygen consumption at 4 km/hr and 0% grade was 11.4 ml/kg b. wt., 13.6 at 6% grade, and 16.21/kg b. wt. at 9% grade in a free walking. In back load walking oxygen consumption at 4km/hr and 0% grade was 12.3 ml/kg b.wt.,14.9 at 6% grade, and 18.7 ml/kg b.wt. In hand load walking the oxygen consumption was the greatest, namely, 13.9 at 0% grade, 17.9 at 6%, and 20.0 ml/kg b. wt. at 9% grade. 4. Both in level and uphill walking the changes in pulmonary ventilation and heart rate paralleled with oxygen consumption. 5. The changes in heart rate and breathing frequency in hand load were characteristic. Both in level and uphill walk breathing frequency increased to 30 per minute when a load was held on hand and showed a small increase as the exercise became severe. In the other method of load carrying the Peak value of breathing frequency was less than 30 Per minute. Heart rate showed 106 beats/minute even at a speed of 4 km/hr when a load was held on hand, whereas, heart rate was between, 53 and 100 beats/minute in the other types of load carriage. 6. Number of strides per minute in level walking increased as the speed increased. At the speed floater than 5 km/hr number of strides per minute of load carrying walk was greater than that of free walking. In uphill walk number of strides per minute decreased as the grade increased. Number of strides in hand load walk was greatest and back load walk showed the same number of strides as the free walk.

  • PDF

Critical Care before Lung Transplantation

  • Lee, Jin Gu;Park, Moo Suk;Jeong, Su Jin;Kim, Song Yee;Na, Sungwon;Kim, Jeongmin;Paik, Hyo Chae
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.197-205
    • /
    • 2018
  • Lung transplantation is widely accepted as the only viable treatment option for patients with end-stage lung disease. However, the imbalance between the number of suitable donor lungs available and the number of possible candidates often results in intensive care unit (ICU) admission for the latter. In the ICU setting, critical care is essential to keep these patients alive and to successfully bridge to lung transplantation. Proper management in the ICU is also one of the key factors supporting long-term success following transplantation. Critical care includes the provision of respiratory support such as mechanical ventilation (MV) and extracorporeal life support (ECLS). Accordingly, a working knowledge of the common critical care issues related to these unique patients and the early recognition and management of problems that arise before and after transplantation in the ICU setting are crucial for long-term success. In this review, we discuss the management and selection of candidates for lung transplantation as well as existing respiratory support strategies that involve MV and ECLS in the ICU setting.

A Study on the Influential factors on Visitors' Satisfaction Level in Exhibition Space - Focused on the Seoul Living Design Fair 2005 - (전시 공간 디자인이 관람객 만족도에 미치는 영향에 관한 연구 - Seoul Living Design Fair 2005를 중심으로 -)

  • Choi, Jin-Hwa;Yoon, Ji-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.255-264
    • /
    • 2006
  • This study started from the premise that the satisfaction of visitors in large-scaled design-related fair has co-relation with the environmental and contextual factors such as contents, lighting, the number and location of rest area, crowdedness, ventilation and circulation. The research was made in Seoul Living Design Fair 2005. 102 samples from 132 who answered to the questionnaire with likert-scaled and open questions were selected for the data, which were statistically analyzed through SPSS 12.0 program to explore the co-relation between the environmental factors and the satisfaction level of visitors. The findings showed that overall satisfaction level was in the middle of the scale, which means satisfied nor unsatisfied. The visitors showed relatively high satisfaction in the two factors-the contents of the fair and lighting system compared to the other factors such as the number and location of rest area, sign system, ventilation crowdedness and circulation. Even though the visitors had difficulties in circulation and showed various types in circulation, it did not seem to have a significant influence on the overall satisfaction level because it might be offset by the contents of the fair. Also, the visitors showed similar satisfaction level regardless of the type of circulation. It can be concluded that the main factors mentioned above should be considered to achieve higher satisfaction level and provide better environment in the large-scaled fair.

Promoted Growth and Development of Carnation Plantlets In Vitro by Ventilation and Combined Red and Blue Light

  • Nguyen, Quan Hoang;Thi, Luc The;Park, Yoo Gyeong;Jeong, Byoung Ryong
    • FLOWER RESEARCH JOURNAL
    • /
    • v.26 no.4
    • /
    • pp.166-178
    • /
    • 2018
  • In this study, the principal objective was to investigate the effect of light quality and vessel ventilation on the growth and development, physiology, activities of antioxidant enzymes, and contents of mineral nutrients of carnation (Dianthus caryophyllus L.) 'Marble Beauty'. Single node cuttings stuck into the plant growth regulator (PGR)-free MS medium in containers covered with caps with or without a ventilation filter were cultured first four weeks under white and then additional four weeks under either white (control), blue, red, or red + blue light emitting diodes (LEDs) for 56 days. Interestingly, a ventilated culture condition not only reduced the percentage of the hyperhydricity, but also increased the total chlorophyll content (Chl a + Chl b) of the plantlets as compared to the non-ventilated condition. In addition, blue LEDs produced plantlets with the greatest number of shoots and red LEDs produced plantlets with the greatest shoot length. The quality of plantlets was improved under a ventilation condition. Besides, under a ventilated condition, red + blue LEDs raised APX activity, and blue LEDs not only raised the activity of the CAT, but also increased tissue contents of such elements as K, Ca, Mg, Zn, Mn and Fe. The red LEDs increased contents of B and Si under a ventilated condition, and Na accumulation under a non-ventilated condition. Thus, including blue or red LEDs as the light source in a ventilated culture condition will produce plantlets of carnation 'Marble Beauty' in vitro with improved quality.

Development of Culture System for Masspropagation and Acclimatization of Tissue Cultured Plantlets (유식물체 증식.순화용 배양시스템 개발)

  • Han, K.S.;Heo, J.W.;Kim, S.C.;Lee, Y.B.;Kim, S.C.;Im, D.H.;Choi, H.G.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.109-114
    • /
    • 2007
  • In mass production of seed-potato plantlets, the processes for in vitro propagation and ex vitro acclimatization with a high cost should be improved by a culture system with environmental control using scaled-up culture vessels. The experiment was conducted to design a hydroponic culture system for enhancement of growth and development of seed-potato (Solanum tuberosum) plantlets cultured under photoautotrophic (without sugar in culture medium) conditions with controlled light intensity and ventilation rate. The culture system was consisted of scaled-up culture vessels, ventilation pipes, a multi-cell tray and an environmental control system (ECS) for optimum controlling in temperature, light intensity, ventilation rate, and culture-medium supply. Growth and development of the plantlets was significantly increased under the ECS compared with a conventional culture system (CCS) of photomixotrophic culture (with sugar in culture medium) using small scale vessels. For 21 days, leaf area of the plantlets was expanded more than 2 times, and number of internodes also approximately 4 times greate. under the ECS. In addition, the photoautotrophic growth in sweetpotato (Ipomoea batatas) and chrysanthemum (Chrysanthemum morifolium) plantlets was greater more than 2 times compared with the CCS.

Effects of a tunnel ventilation system within the tie-stall barn environment upon the productivity of dairy cattle during the winter season

  • Sarentonglaga, Borjigin;Sugiyama, Tatsuhiro;Fukumori, Rika;Nagao, Yoshikazu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.5
    • /
    • pp.748-756
    • /
    • 2019
  • Objective: The objective of this study was to examine the effect of using a tunnel ventilation system within the dairy barn environment upon the productivity of dairy cows during the winter season. Methods: The study was performed at the University Farm, Faculty of Agriculture, Utsunomiya University. Twenty-one Holstein dairy cows (5 heifers and 16 multiparous) were enclosed in a stall barn. Unventilated (UV) and tunnel-ventilated (TV) was operated by turns every other week, and a number of key parameters were measured in the barn, including tunnel ventilation output, temperature, relative humidity, gas concentrations (oxygen [$O_2$], carbon dioxide [$CO_2$], and ammonia [$NH_3$]). Also, skin and rectal temperature, respiratory rate, blood gas concentrations, and bacterial count were measured from nipple attachments on ten cows. The amount of fodder left uneaten, and general components and somatic cell count of the milk were measured. Results: As for our dairy barn environment, air temperature dropped significantly with the passage of time with TV. Humidity was significantly higher with TV at 0600 h compared to UV, while $CO_2$ and $NH_3$ concentrations with UV were significantly higher than with TV at 0000 h and 0600 h. Skin temperature was significantly lower with TV compared to UV at 0000 h and 0600 h. Respiratory rate was also significantly lower at 0600 h with TV than with UV. Bacterial count for the nipple attachments was significantly lower with TV than with UV at 0600 h. The amount of leftover fodder was significantly less with TV in comparison with UV. Conclusion: Our results suggest that a TV system in the winter barn results in environmental improvements, such as reductions in unfavorable gas concentrations and bacterial growth. Consequently, it is expected that barns utilizing a TV system will be beneficial for both animal health and production.

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

A Study on Application of Shaft-box Type Double Skin to Apartment Building (공동주택에 대한 Shaft Box형 이중외피의 적용에 관한 연구)

  • Roh, Ji Wooung
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2013
  • The balcony of our apartment building consists of unique construction similar to double skin. It is announced broadly that double skin is very effective system in improvement of natural ventilation and indoor thermal environment, and outdoor sound protection. So, for the improvement of indoor climate and energy saving, many peoples studied about environmental performance of our balcony construction. This study focus on shaft box facade, special form of box window construction. It consists of a system of box window with continuous vertical shafts that extend over a number of stories to create a stack effect. Proto-type was decided by analyzing various types of exiting apartments. Shaft box type balcony was created by setting up shaft space at a part of balcony. Air flow and contribution of air temperature were simulated, performance of shaft box type balcony was compared with existing balcony. Finally, we confirmed that shaft box type balcony has many possibility for improvement of indoor environment.