• 제목/요약/키워드: Nuclear medicine image

검색결과 616건 처리시간 0.026초

갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가 (The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement)

  • 이현국;강현수;양승오;한만석
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

약물 및 비약물 자극에 의한 도파민 유리 영상 (Imaging of Dopamine Release Induced by Pharmacologic and Nonpharmacologic Stimulations)

  • 조상수;김상은
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권2호
    • /
    • pp.158-165
    • /
    • 2007
  • Technological advances in molecular imaging made it possible to image synaptic neurotransmitter concentration in living human brain. The dopaminergic system has been most intensively studied because of its importance in neurological as well as psychiatric disorders. This paper provides a brief overview of recent progress in imaging studies of dopamine release induced by pharmacologic and nonpharmacologic stimulations.

Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가 (Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application)

  • 김정수;김병진;김진의;우재룡;김현주;신희원
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.13-18
    • /
    • 2008
  • 목적: 다양한 algorism에 의한 영상처리기법은 핵의학 영상을 결정짓는 중요한 부분을 차지하고 있다. 이에 새로운 영상처리기법인 SIEMENS (made by pixon)사의 Onco. flash processing reconstruction을 적용하여 기존의 영상처리기법을 이용한 영상과 비교 분석함으로써 그 임상적 유용성을 평가한다. 대상 및 방법: 1) Scan speed의 차이에 의한 whole body bone scan을 시행하고, raw data와 processing data의 imaeg quality를 비교 분석하여 상대 평가한다. 2) Bone static scan을 acquisition count를 달리하여 시행하고, raw data와 processing data의 image quality를 비교 분석하여 상대 평가한다. 3) 4 quadrant - bar phantom을 이용하여 raw data와 processing data와의 육안적 평가를 통한 image quality를 확인한다. 4) LSF을 통한 raw data와 processing data의 FWHM을 구하여 해상력 평가를 확인한다. 결과: 1) Whole body bone scan을 시행하여 본원 핵의학 판독의의 blinding test한 결과 scan speed 20 cm/min의 raw data와 30 cm/min의 processing data에는 임상 판독에 영향을 미칠 수준의 image quality 저하가 없었으나, 40 cm/min processing data는 영상 판독과 진단에 오류의 가능성을 배제 할 수 없는 image quality의 향상을 볼 수 없었다. 2) Bone static scan의 경우 200 kcts processing data는 200 kcts raw data보다 확실한 image quality의 향상을 가져왔으며 400 kcts raw data와 비교한 본원 핵의학 판독의 blinding test 결과 판독과 진단에 무리가 없을 수준의 유사한 image quality를 보였다. 3) 4 quadrant - bar phantom을 이용하여 raw data와 processing data와의 육안적 평가는 processing을 통한 image quality의 향상을 확인할 수 있었다. 4) LSF을 통한 raw data와 processing data의 FWHM 평가 결과, resolution의 뚜렷한 증가나 감소의 확인은 할 수 없었다. 이는 noise level의 감소와 high S/N ratio 때문이라 판단된다. 결론: 기존의 영상과 비교 분석하여 평가한 결과 Onco. flash processing reconstruction을 적용한 경우 일정 수준까지 뚜렷한 image quality의 향상을 보였으며, 이는 장비 가동률의 상승과 환자 대기일수의 단축 그리고 저선량 검사에 따른 방사선 피폭에 대한 적극적 방어의 관점에서 현재 임상 핵의학에 충분한 유용성과 타당성이 있을 것으로 사료된다.

  • PDF

전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가 (Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan)

  • 심동오;정우영;류재광;박철홍;김윤재
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가 (Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET)

  • 김재일;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.20-23
    • /
    • 2016
  • 심장 질환에 의한 사망률의 점차적으로 증가하므로 heart PET 검사가 많이 활용되고 있다. 하지만 static mode의 경우 심장 움직임으로 인해 흐림이 많이 발생하므로 심전도와 동기화 검사를 통해 보다 공간 분해능을 향상 시킬 수 있을 겁니다. 5명의 내원 환자에 대해 10 mCi의 $^{13}N-ammonia$를 주입하면서 ECG와 gate 한 list mode 획득하고, non-gate영상과 gated 영상을 재구성 후, 비교 평가하였다. 반치폭은 23.34% 증가하였고, 두 영상간의 감쇠 영상은 많은 차이가 남을 알 수 있었으며, 눈가림 실험에서도 8명 모두가 gated PET 영상이 우수함을 말해 주었다. 심전도와 동기화를 통해 심장 PET 영상의 공간 분해능이 우수해졌으며, EF value, wall motion, QPS, QGS와 같이 다양한 정량적 평가에 시행할 수 있어서, 보다 많은 정보를 환자에 제공해줌을 알 수 있었다.

  • PDF

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

뇌혈류 SPECT에서 정규화감산영상을 이용한 뇌혈류비축능의 정량적 평가에 관한 연구 (Quantitative Assessment of Cerebral Perfusion Reserves Using Normalized Difference Ratio Image of Brain SPECT)

  • 이재성;곽철은;박광석;정재민;이동수;정준기;이명철;고창순
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.279-282
    • /
    • 1996
  • Sequential brain SPECT imaging has been used to assess the cerebral perfusion reserve(CPR) in cerebrovascular diseases(CVD). We have realized a parametric images of CPR using normalized difference ratio and deadtime correction. For the anatomical localization of CPR, the parametric images were registered to the contours of the cerebral regions using optimal threshold method. The parametric imags reflected the CPR more reliably and distinctively. We conclude that the qunatitative estimation of CPR using normalized difference ratio image could be useful for the diagnosis and assessment of postoperative prognosis in CVD.

  • PDF

Onco Flash에서 매개변수 변화에 따른 영상의 질 평가 (Evaluation of Image Quality by Parameter Change in Onco Flash)

  • 차은선;노익상;김기;최춘기;석재동
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.30-34
    • /
    • 2009
  • 목적 : 현재 신속한 검사 및 환자의 대기 시간 단축에 따른 제한적인 영향을 가지고 있는 whole body bone scan의 단점을 보완하기 위한 다양한 프로그램들이 개발되어 사용되고 있다. 본 연구는 스캔속도와 알파 값에 따른 FWHM를 이용하고 영상의 육안평가를 통해서 우수한 영상의 질을 얻을 수 있는 매개변수로 임상의 유용성을 얻고자 한다. 실험재료 및 방법 : Siemens (e.cam)사의 감마카메라에서 spatial resolution phantom과 four quadrant bar phantom을 이용하였다. spatial resolution phantom을 가지고 scatter와 non scatter로 Onco Flash를 적용해서 스캔속도 15, 20, 25, 30, 35, 40 cm/min으로 FWHM을 비교하였다. 또한 Onco Flash의 알파값 (0~100%)에서 10%씩 증가하여 스캔속도 30 cm/min 기준으로 계수율과 bar phantom 영상을 얻어 육안적 평가를 하였다. 결과 : Onco Flash를 적용한 scatter에서 스캔속도에 따라 FWHM은 9.37, 9.40, 9.28, 9.30, 9.31, 9.53 mm이고, non scatter에서는 스캔속도에 따라 FWHM은 8.42, 8.32, 8.2, 8.25, 8.35, 8.52 mm이었다. 알파 값은 10%씩 증가할수록 계수율도 증가하고, 육안적 평가는 40% 이상에서 인공물이 나타나기 시작하기 때문에 알파 값은 30% 이하에서 적합하였다. 따라서 Onco Flash를 사용한 스캔속도가 25~35 cm/min에서 알파값 30% 적용 시 FWHM이 평균 9.3 mm로서 15~40 cm/min를 벗어나는 값 보다 공간분해능이 향상되었다. 결론 : Whole body bone scan의 영상을 향상시킬 수 있는 적정 매개변수를 알 수 있었으며 검사 시간을 단축하면서 영상의 질을 향상 할 수 있도록 매개변수들을 적용해 보아 임상적용에 적합한 범위를 얻어 검사자에게 유용한 지표가 될 것이라 사료된다.

  • PDF