• 제목/요약/키워드: Nuclear medicine image

검색결과 616건 처리시간 0.041초

핵의학 투고 논문 분류 및 방향성 고찰 (Classification of submitted nuclear medicine dissertation and directional consideration)

  • 조호연;우영란;서강록;홍건철
    • 핵의학기술
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

생체발광영상에서 포톤 검출 정량화를 위한 보정기법의 개발 (Development of Correction Technologies for Quantification of Photon Measurement in Bio-Luminescence Image)

  • 탁윤오;김현식;박형주;최흥국;최은서;한수욱;이병일
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.85-92
    • /
    • 2011
  • Bioluminescence imaging (BLI) is the most sensitive animal imaging technique for molecular imaging research. Generally, highly sensitive CCD is used to detect an optical probe introduced in a living mouse. However, in many cases, the light signal emitted from a probe is too small to detect because it is scattered and attenuated by the tissue prior to being detected. The problem is that scattering and attenuation not only inhibit accurate measurement but also make image quality down. Thus we introduced a new method to reduce noise by using property of CCD and method to improve image quality of bioluminescence image by using two steps Gaussian blurring.

영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교 (Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT)

  • 김우현;정우영;이주영;류재광
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2009
  • 최근 영상 처리 기법의 발전으로 영상의 질은 저하시키지 않고 검사 소요시간을 단축시키는 방법들이 개발되고 있다. 특히 단층 촬영의 경우 영상 재구성 방법을 개선하여 영상의 질이 우수한 영상을 획득할 수 있게 되었다. Philips사의 PRECEDENCE 16 감마카메라를 이용해 보편적으로 시행하고 있는 분석법에 의한 FBP 방법과 반복법에 의한 Astonish, 3D OSEM 방법을 이용해 각각 영상을 재구성하여 정성적인 분석과 정량적인 분석을 통해 영상 획득시간을 다르게 한 영상간의 비교와, 동일한 시간으로 획득한 영상을 비교하여 영상의 질이 우수한 재구성 방법에 대해 연구 하였다. 정성적인 분석을 위해 blind test를 한 결과, 영상 획득시간에 따른 영상의 질은 거의 차이가 없는 것을 확인할 수 있었다. 또한 정량적인 분석을 통해서도 영상 획득시간에 따른 영상의 질은 통계적으로 유의한 차이가 없었다. 하지만 영상 획득시간이 동일한 영상을 재구성 방법에 따라 분석한 결과는 통계적으로 유의한 차이가 있음을 확인할 수 있었다. 영상의 질은 반복법을 이용하는 Astonish에 의해 재구성된 영상이 해상력이 좋고 임상적으로 진단적 정보를 제공하는데 우수한 영상으로 판단된다. 영상을 재구성하기 위한 소요시간이 길고 저장 공간의 부족 등으로 현재까지 많이 사용되지 않던 반복법에 의한 재구성 방법이 영상의 질은 향상시키고 검사시간은 단축 할 수 있는 방법이 될 수 있음을 확인하였다.

  • PDF

게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가 (The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan)

  • 이동훈;유희재;이종훈;정우영
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가 (Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network)

  • 김종완;김정열;임한상;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.15-19
    • /
    • 2020
  • 본 연구는 최근에 활발히 연구되고 있는 딥러닝 기술인 생성적 적대 신경망(GAN)을 핵의학 영상에 적용하여 잠재적으로 유용성이 있는지 확인해보고자 하였다. 본원에서 18F-FDG Brain PET/CT검사를 진행한 30명의 환자를 대상으로 하였고 List모드로 15분 검사한 후 이를 1, 2, 3, 4, 5분 초기획득시간 이미지로 재구성하였다. 이 중 25명의 환자를 GAN모델의 학습을 위한 트레이닝 이미지로 사용하고 5명의 환자를 학습된 GAN모델의 검증을 위한 테스트 이미지로 사용하였다. 학습된 GAN모델에 입력으로 1, 2, 3, 4, 5분의 초기획득 이미지를 넣고 출력으로 15분 인공지능 표준획득 이미지를 획득한 후 이를 기존의 15분 표준획득시간 검사 이미지와 비교 평가하였다. 평가에는 정량화된 이미지 평가방법인 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수를 이용하였다. 평가 결과 초기획득시간 이미지에서 1에서 5분으로 갈수록 실제 표준획득시간 이미지에 가까운 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수 수치를 나타내었다. 이러한 연구를 통해 앞으로 인공지능 기술이 핵의학 분야에서 의료영상의 획득시간 단축과 관련하여 중요한 영향을 미칠 수 있을 것으로 사료된다.

핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰 (Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan)

  • 이은별;김재일;도용호;임정진;조성욱;노경운
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.92-96
    • /
    • 2018
  • 핵의학 간담도 검사 시, 담낭의 수축력을 정량적으로 평가하기 위하여 지방식(fatty meal)을 이용한 전면상에서의 담낭박출률(gallbladder ejection fraction ; GB EF%)을 진단에 이용하고 있다. 하지만, 담낭과 다른 구조물이 전면상에서 겹쳐질 경우, 담낭 박출률 평가가 정확히 이루어지지 않는다. 이러한 오차를 줄이기 위해 본 연구에서는 전면상과 우측 측면상에서 계산한 GBEF%의 유의한 차이가 있는 지 알아보고자 한다. 본원에 내원한 임의의 환자 50명을 대상으로 $^{99m}Tc$-Mebrofenin 370 MBq를 정맥주사 후 간담도 검사를 실행하였다. 검사는 SKYLIGHT(Philips, United States)을 이용하여 10분, 20분, 30분, 60분, 그리고 지방식(치즈와 우유)을 시행하고 30분 후에 90분 째, 전면상과 우측 측면 영상을 획득하였다. JETstream workspace 프로그램에서 60분째와 90분째 전면상과 우측 측면상에서 GBEF%을 구하였다. 보다 정확한 관심영역 설정을 위해 CT영상을 참고하였고, 4명의 방사선사가 동일한 영상에서의 GBEF%을 구하여 평균값을 계산하였다. 통계분석프로그램SPSS version23(SPSS Inc. USA)을 이용하여 전면상과 우측 측면상에서 GBEF%의 차이에 유의한 차이가 있는지 평가하였다. 무작위 50명 환자의 전면상에서 GBEF%의 평균값은 63.2고, 우측 측면상에서 GBEF%의 평균값은 62.7으로 전면상 대비 우측 측면상에서 0.5% 감소하였다. 전면상과 우측 측면상에서 GBEF%의 대응표본 t-검정 결과 P>0.05으로 유의한 차이가 없었다. 이를 통해 전면상에서 담낭과 다른 구조물이 분리되지 않아 담낭박출률의 오차가 발생하는 경우, 우측 측면상을 이용하여 GBEF%을계산하면 보다 더 정확한 담낭박출률이 평가되는 것으로 사료된다.

Median modified wiener filter for improving the image quality of gamma camera images

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2328-2333
    • /
    • 2020
  • The filter technique was applied to noise images, as noise is the significant factor that cause poor image quality due to lower photon counting. The purpose of this study is to confirm that image quality can be improved using the median modified Wiener filter (MMWF) technique; this is achieved via a National Electrical Manufacturers Association International Electrotechnical Commission body phantom with four large spheres that are filled with the 99mTc radioisotope when evaluating the image quality. Conventional filters such as Wiener, Gaussian, and median filters were designed, and signal to noise ratio, coefficient of variation, and contrast to noise ratio were used as the evaluation parameters. The improvement in the image quality was in the following order, from the least to the highest improvement, in all cases: Wiener filter, Gaussian filter, median filter, and the MMWF technique. The results show that the image quality was improved from 20.6 to 65.5%, 7.4-40.3%, and 12.7-44.7% for the SNR, COV, and CNR values, respectively, when using the MMWF technique, compared with the use of conventional filters. In conclusion, our results demonstrated that the MMWF technique is useful for reducing the noise distribution in gamma camera images.