갑상선 유두암의 슬개골 전이 (A Case of Patella Metastasis of Papillary Thyroid Carcinoma)

  • 한은지;최우희;정용안;손형선;강창석
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.79-82
    • /
    • 2009
  • A 73-year-old man presented with a chief complaint of progressive left knee pain for two months. He had a history of total thyroidectomy and central lymph node dissection due to papillary thyroid carcinoma three months ago. MRI images revealed a solid mass in the left patella. A solid mass demonstrated low signal on T1 weighed image, and high signal on T2 weighed image. And whole body bone scan showed focal photon defect in same lesion of left patella. The histologic result of left knee lesion was adenocarcinoma, consistent with metastatic papillary thyroid carcinoma. Although patellar metastasis of papillary thyroid carcinoma is very rare, when knee pain and radiologic abnormality are noted, differential diagnosis of metastasis is necessary.

원발성 간비장 B세포성 림프종에서 치료전과 치료 후 F-18 FDG PET/CT 소견 (Primary Hepatosplenic B-cell Lymphoma: linitial Diagnosis and Assessment of Therapeutic Response with F-18 FDG PET/CT)

  • 강성민;이홍제;서지형;이상우;안병철;이재태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권4호
    • /
    • pp.333-336
    • /
    • 2008
  • A 52-year-old woman with a history of general weakness, fatigue, weight loss, elevated serum levels of liver transaminase enzyme for three months underwent an F-18 FDG PET/CT scan to evaluate a cause of the hepatosplenomegaly found on abdominal ultrasonography. Initial PET/CT revealed markedly enlarged liver and spleen with intense FDG uptake. Otherwise, there were no areas of abnormal FDG uptake in whole body image. Histological evaluation by a hepatic needle biopsy demonstrated diffuse large B cell type lymphoma and final diagnosis for this patient was hepatosplenic B-cell lymphoma. She received five cycles of CHOP chemotherapy, and second PET/CT scan was followed after then. Follow-up PET-CT revealed normal sized liver with disappearance of abnormal FDG uptake. Hepatosplenic B-cell lymphoma is relatively rare and mostly presents as single or multiple nodules.1,2 Diffuse type hepatosplenic lymphoma is extremely rare and poorly recognized entity.3 The diagnosis is very difficult and complicated by the presence of misleading symptoms.4 In this rare hepatosplenic B-cell lymphoma case, F-18 FDG PET/CT scan provided a initial diagnostic clue of hepatosplenic lymphoma and an accurate chemotherapy response.

Assessment of a Deep Learning Algorithm for the Detection of Rib Fractures on Whole-Body Trauma Computed Tomography

  • Thomas Weikert;Luca Andre Noordtzij;Jens Bremerich;Bram Stieltjes;Victor Parmar;Joshy Cyriac;Gregor Sommer;Alexander Walter Sauter
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.891-899
    • /
    • 2020
  • Objective: To assess the diagnostic performance of a deep learning-based algorithm for automated detection of acute and chronic rib fractures on whole-body trauma CT. Materials and Methods: We retrospectively identified all whole-body trauma CT scans referred from the emergency department of our hospital from January to December 2018 (n = 511). Scans were categorized as positive (n = 159) or negative (n = 352) for rib fractures according to the clinically approved written CT reports, which served as the index test. The bone kernel series (1.5-mm slice thickness) served as an input for a detection prototype algorithm trained to detect both acute and chronic rib fractures based on a deep convolutional neural network. It had previously been trained on an independent sample from eight other institutions (n = 11455). Results: All CTs except one were successfully processed (510/511). The algorithm achieved a sensitivity of 87.4% and specificity of 91.5% on a per-examination level [per CT scan: rib fracture(s): yes/no]. There were 0.16 false-positives per examination (= 81/510). On a per-finding level, there were 587 true-positive findings (sensitivity: 65.7%) and 307 false-negatives. Furthermore, 97 true rib fractures were detected that were not mentioned in the written CT reports. A major factor associated with correct detection was displacement. Conclusion: We found good performance of a deep learning-based prototype algorithm detecting rib fractures on trauma CT on a per-examination level at a low rate of false-positives per case. A potential area for clinical application is its use as a screening tool to avoid false-negative radiology reports.

반신마비성 반사성교감신경 이영양증후군 환자의 골스캔상 견관절 섭취 (Shoulder Uptake in the Bone Scintigraphy in Patients with Hemiplegic Reflex Sympathetic Dystrophy Syndrome)

  • 이종진;정준기;이동수;홍준범;한태륜;이명철
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.288-293
    • /
    • 2004
  • 목적: 삼상골스캔상의 증가된 손목과 손의 관절의 증가된 섭취는 반사성교감신경 이영양증후군의 소견이다. 반신마비성 반사성교감신경 이영양증후군 환자에서의 병측 견관절 섭취 증가는 드물지 않은 소견으로서 이번 연구에서는 이런 환자들에서의 견관절 섭취의 임상적 의미를 알고자 연구를 시행하였다. 대상 및 방법 : 뇌졸중으로 반신마비가 된 환자 중 임상적으로 반사성교감신경 이영양증후군으로 진단된 23명의 환자를 대상으로 하였다(남:녀=16:7, 좌:우=11:12). 평균나이는 $63{\pm}10$세였다. 10명의 정상 자원자의 데이터를 대조군으로 사용하였다(평균 나이 $60{\pm}5$, 남:녀=1:9). 삼상골스캔은 뇌졸중 발병 후 $59{\pm}32$ 일에 시행하였다. 관심영역을 그려서 삼상의 양손의 우/좌 섭취비를 각각 구하였고, 이를 지연 영상에서의 견관절 섭취 우/좌 섭취비와 비교하였다. 손의 관심 영역은 손목을 포함하였다. 검사의 예민도는 정상 대조군의 데이터를 이용하여 결정하였다. 결과: 관류 영상과 혈액 풀 영상, 지연 영상의 손의 우/좌 섭취비를 이용한 삼상골스캔의 민감도는 각각 45%, 76%, 78%이었다. 지연 영상의 견관절 섭취비를 이용한 민감도는 74%이었다. 지연영상의 손 우/좌 섭취비와 견관절 우/좌 섭취비는 유의한 상관관계를 보였다(Spearman's R=0.824, p<0.001). 결론 : 지연 영상에서의 견관절 섭취는 지연 영상의 손 섭취와 유의한 상관 관계를 보였다. 병측 견관절 섭취 증가 소견은 반신마비성 반사성교감신경 이영양증후군 환자의 진단에 도움을 주는 소견이다.민감도는 스캐너의 횡축방향 708.6 (2D), 2931.3 (3D) counts/sec/MBq, 횡축방향 중심에서 10cm 벗어난 지점에서 728.7 (2D), 3398.2 (3D) counts/sec/MBq 이었다. 산란 분획은 0.19 (2D), 0.49 (3D)이었고 최고 참 계수율과 NECR은 2차원 영상 획득 모드에서 40.1 kBq/mL 일 때 64.0 kcps, 40.1 kBq/mL 일 때 49.6 kcps, 3차원 영상 획득 모드에서 4.76 kBq/mL 일 때 53.7 kcps, 4.47 kBq/mL 일 때 26.4 kcps이었다. 결론: 이 실험에서 NEMA NU2-2001로 측정한 PET스캐너의 물리적 특성은 PET스캐너에 대한 객관적 평가 및 최적화 된 영상 획득과 분석에 유용할 것이다.로 사료되었다.률 또한 신경회로망(59%)과 핵의학 전문가(72%)의 진단 성적이 거의 다르지 않았다. 결론: 이 연구에서 개발한 간질병소 국소화를 위한 신경회로망 시스템은 측두엽간질 감별 진단에 도움이 될 것으로 기대된다. 생체광학 영상을 이용한 다약제내성 유전자 및 Pgp 발현 연구는 아직 시작단계이나, 분자 생물학적 영상법의 발전과 함께 MRI 기술등에도 이용될 수 있으므로 향후 많은 연구가 있을 것으로 기대된다.{\mu}M$에서는 각각 40%와 5%만 섭취되었다. MTT assay상 K562(Adr)세포에서는 verapamil $100{\mu}M$ 이상에서는 유의하게 낮았으나 다른 세포는 $200{\mu}M$까지에도 차이가 없었다. PKC 아형의 분석상 PKC $\varepsilon$

PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가 (Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image)

  • 박선명;이혁;홍건철;정은경;최춘기;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.41-46
    • /
    • 2011
  • 영상장치를 이용한 검사 시 영상의 질은 검사결과와 밀접하게 연관되어 있으며, 이는 영상획득 조건들과 이에 대한 평가방법으로 인해 달라 질 수 있다. 본 연구에서는 영상획득 시 사전설정법(Pre-set method)차이에 따른 영상의 질을 평가하였다. 장비는 PET/CT Discovery STe16(GE Healthcare, Milwaukee, USA)을 사용하였으며, Chest PET Phantom (실험 1)과 94 NEMA Phantom (실험 2)을 이용하였다. 실험 1의 경우 3.5, 6.0, 8.6 kBq/mL, 실험 2의 경우는 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL의 $^{18}F$-FDG를 채웠고, 열소와 배후방사능과의 방사능 농도는 4:1의 비율을 유지하였다. 각 실험은 CT 투과촬영 후 3D로 2분 30초/프레임으로 시간설정법(Time-set method)과 1억 계수의 계수설정법 (Count-set method)을 적용하여 방출촬영 하였다. 영상의 질에 대한 평가는 잡음 등가 계수율 (Noise Equivalent Count Rate, NECR)과 신호 대 잡음비 (Signal to Noise Ratio, SNR)를 이용하였다. 실험 1에서 NECR과 SNR은 방사능 농도의 증가에 따라 시간설정법에서 53.7, 66.9, 91.4 과 7.9, 10.0, 11.7로 평가 모두에서 증가함을 보였으나, 계수설정법은 53.8, 69.1, 97.8과 14.1, 14.7, 14.4로 SNR은 NECR과 다르게 증감현상을 보이지 않았다. 또 다른 모형실험인 실험 2에서도 NECR과 SNR은 방사능 농도가 증가에 따라 시간설정법에서 45.1, 70.6, 95.3 115.6 134.6 162.2 과 7.1, 8.8, 10.6, 11.5, 12.7, 14.0으로 증가함을 보였으나, 계수설정법에서는 42.1 67.3 92.1 112.2 130.7 158.7 과 15.2, 15.9, 15.6, 15.4, 15.5, 14.9로 실험 1에서와 마찬가지로 SNR에서는 증감현상을 보이지 않았다. 사전설정법 변화와 관계없이 단위 질량당 방사능량 증가는 영상의 질도 비례하여 향상된다. 그러나 동일한 단위 질량당 방사능량에서는 영상획득의 시간을 늘려 총계수값을 증가시켜도 NECR에 영향을 주지는 않는다. 이는 NECR을 이용한 영상 질 평가는 영상획득 시 얻은 총 계수 값보다는 단위 시간당의 계수율이 영향을 준다는 것을 의미한다고 할 수 있다. 실험 모두에서 계수설정법으로 얻은 경우에는 단위 질량당 방사능량의 증가에도 불구하고 거의 비슷한 SNR값을 보이게 된다. 따라서 좋은 질의 영상을 얻기 위해서는 총 계수값의 증가보다는 단위질량당 방사능량을 높여야 하며, SNR만을 이용한 영상의 질에 대한 평가는 적절하지 않을 수 있다는 점을 고려하여야 한다.

  • PDF

자기 지도 학습훈련 기반의 Noise2Void 네트워크를 이용한 PET 영상의 잡음 제거 평가: 팬텀 실험 (The Evaluation of Denoising PET Image Using Self Supervised Noise2Void Learning Training: A Phantom Study)

  • 윤석환;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.655-661
    • /
    • 2021
  • Positron emission tomography (PET) images is affected by acquisition time, short acquisition times results in low gamma counts leading to degradation of image quality by statistical noise. Noise2Void(N2V) is self supervised denoising model that is convolutional neural network (CNN) based deep learning. The purpose of this study is to evaluate denoising performance of N2V for PET image with a short acquisition time. The phantom was scanned as a list mode for 10 min using Biograph mCT40 of PET/CT (Siemens Healthcare, Erlangen, Germany). We compared PET images using NEMA image-quality phantom for standard acquisition time (10 min), short acquisition time (2min) and simulated PET image (S2 min). To evaluate performance of N2V, the peak signal to noise ratio (PSNR), normalized root mean square error (NRMSE), structural similarity index (SSIM) and radio-activity recovery coefficient (RC) were used. The PSNR, NRMSE and SSIM for 2 min and S2 min PET images compared to 10min PET image were 30.983, 33.936, 9.954, 7.609 and 0.916, 0.934 respectively. The RC for spheres with S2 min PET image also met European Association of Nuclear Medicine Research Ltd. (EARL) FDG PET accreditation program. We confirmed generated S2 min PET image from N2V deep learning showed improvement results compared to 2 min PET image and The PET images on visual analysis were also comparable between 10 min and S2 min PET images. In conclusion, noisy PET image by means of short acquisition time using N2V denoising network model can be improved image quality without underestimation of radioactivity.

$^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성 (Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$)

  • 신채호;표성재;김봉수;조용귀;조진우;김창호
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.65-71
    • /
    • 2011
  • 근래의 심근 관류 SPECT를 위한 검사 장비는 진단의 정확도가 높아졌을 뿐만 아니라 검사 시간을 단축함으로써 환자의 편의성을 높이고 움직임에 대한 artifact를 줄이는 방향으로 발전되고 있다. 본 연구에서는 기존의 심근 관류 SPECT와 비교하여 IQ SPECT에 맞는 protocol을 design 하고 IQ SPECT의 특성과 유용성에 대하여 알아 보고자 하였다. Simens사의 Symbia T6 SPECT/CT를 이용하여 LEHR collimator와 Multiple confocal collimator에 대하여 acrylic dish에 $^{99m}Tc$ 37MBq을 넣고 5 cm, 10 cm, 20 cm, 30 cm, 40 cm 거리에서 각각 sensitivity ($cpm/{\mu}Ci$)를 측정 하였다. 그리고 Sensitivity 측정 결과를 바탕으로 기존의 일반적인 심근관류 SPECT를 기준으로 IQ SPECT protocol을 design 후 Anthropomorphic torso phantom을 사용하여 심근 관류 SPECT를 시행하여 비교하고, LEHR collimator의 영상 재구성에 따른 FWHM 비교를 위해 $^{99m}Tc$ Line source를 이용하여 기존의 심근 관류 SPECT의 재구성법인 FBP법과 IQ SPECT의 3D OSEM법에 대하여 알고리즘만 변화시켜 FWHM을 측정 비교하였다. Collimator senstivity 측정 결과 IQ SPECT의 multiple confocal collimator의 sensitivity가 LEHR collimator와 비교하여 30 cm 거리에서 sensitivity가 약 4배 정도 더 많아짐을 알 수 있었다. Sensitivity 결과를 바탕으로 IQ SPECT의 기하학적 특성에 맞게 심근 관류 SPECT protocol을 design 하여 phantom 실험을 시행한 결과 기존에 비해 검사시간을 1/4로 단축할 수 있었으며, LEHR collimator를 사용하여 SPECT 검사 후 FBP법과 3D OSEM 법의 재구성 알고리즘에 따른 FWHM 비교에서는 3D OSEM법에서 FWHM이 2배 정도 향상된 결과를 얻었다. 본 연구를 통해 IQ SPECT는 심근관류 SPECT에서 Multiple confocal collimator를 사용하여 감도를 향상시키고 심장에 특화된 기하학적인 영상 획득 방식과 영상 재구성 방법을 통하여 검사 시간을 단축하고 영상의 화질 개선에 도움을 준다. 이로 인해 환자는 전보다 더욱 편안하고 정확한 검사를 수행 할 수 있을 것이며, 추가적으로 더 많은 임상 자료를 통한 연구가 필요할 것이다.

  • PDF

반복적인 $^{131}I$ rituximab 방사면역치료를 시행 받은 비호지킨 림프종 환자 군에서 종양 부위의 영상기반 방사선 흡수선량 평가와 임상적 의의 (Image-Based Assessment and Clinical Significance of Absorbed Radiation Dose to Tumor in Repeated High-Dose $^{131}I$ Anti-CD20 Monoclonal Antibody (Rituximab) Radioimmunotherapy for Non-Hodgkin's Lymphoma)

  • 변병현;김경민;우상근;최태현;강혜진;오동현;김병일;천기정;최창운;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.60-71
    • /
    • 2009
  • 목적: 최근들어 비호지킨 림프종 환자군에서 $^{131}I$ 표지 rituximab을 이용한 반복적인 방사면역치료가 효과적인 치료방법임이 보고되고 있다. 이 연구에서는 $^{131}I$ 표지 rituximab을 이용하여 반복적인 방사면역치료를 시행받은 비호지킨 림프종 환자군에서 치료전 FDG-PET과 치료후 감마카메라를 이용한 전신 평면방출영상을 이용하여 종양의 흡수선량을 평가하였다. 대상 및 방법: 모두 4명의 환자들에게 치료용량의 $^{131}I$ 표지 rituximab ($7270.5{\pm}276.5MBq$)을 정맥주사하였다. 방사면역치료의 반복휫수는 3명에서는 3회, 1명에서는 4회였으며, 7개의 측정가능한 종양에 대해 총 21회의 평가가 이루어졌다. 감마카메라를 이용한 전신 평면방출영상을 방사면역치료 후 5분, 5시간, 24시간, 48시간 및 72시간에 연속적으로 촬영하였고, FDG PET/CT를 방사면역치료 전 1주일 이내와 방사면역치료 후 30일째 되는 날에 각각 촬영하였다. 방사면역치료 전 PET/CT로부터 관상면의 최대강도투사영상을 얻었고, 이 영상에 AMIDE소프트웨어를 이용하여 연속적인 전신 평면방출영상을 중첩시켰는데, 이 과정에서 4개의 해부학적 표지자(양측 어깨와 엉덩이)를 이용하였다. 중첩된 영상에서 종양부위와 왼쪽 안쪽 넓적다리(배경영역)의 관심영역을 그리고, 종양자체의 시간-방사능곡선을 구하였다. PET/CT에 포함된 CT영상으로부터 종양의 부피를 측정했으며, 각각의 종양부위의 SUVmax를 구하여 종양부피와 SUVmax의 방사면역 치료 전후 변화율을 평가하였다. 종양의 흡수선량과 부피변화율 간의 상관관계를 분석하였고, 방사면역치료 횟수에 따라서 종양의 흡수선량 및 부피 변화율에 유의한 차이가 있는지 알아보았다. 결과: 전체 환자군의 종양부위 흡수선량은 $397.7{\pm}646.2\;cGy$ ($53.0{\sim}2853.0\;cGy$)이었다. 방사면역 치료 전 종양의 부피는 $11.3{\pm}9.1\;cc$ ($2.9{\sim}34.2\;cc$)이었고, 치료 후 종양의 부피 변화율은 $-29.8{\pm}44.3%$($-100.0%{\sim}+42.5%$)이었다. 종양의 흡수선량과 부피 변화율 간에는 유의한 상관관계가 관찰되지 않았으며(p>0.05), 방사면역치료 횟수에 따라서 종양의 흡수선량 및 부피 변화율에도 유의한 차이가 관찰되지 않았다(p>0.05). 결론: FDG-PET의 최대강도투사영상을 이용하여 종양의 위치와 경계를 보다 명확하게 파악할 수 있었고, 감마카메라 영상과의 중첩을 통해서 효과적인 종양의 흡수선량평가가 가능하였다.

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

관상동맥질환에서 심장 하이브리드 영상의 임상적 이용 (Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease)

  • 조인호;공은정
    • Journal of Yeungnam Medical Science
    • /
    • 제26권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF