• 제목/요약/키워드: Nuclear magnetic resonance

검색결과 859건 처리시간 0.035초

1H Nuclear Magnetic Resonance of a Ferroelectric Liquid Crystalline System

  • Cha, J.K.;Lee, K.W.;Oh, I.H.;Han, J.H.;Lee, Cheol-Eui;Jin, J.I.;Choi, J.Y.
    • Journal of Magnetics
    • /
    • 제15권2호
    • /
    • pp.61-63
    • /
    • 2010
  • We used $^1H$ nuclear magnetic resonance (NMR) to study the phase transitions and molecular dynamics in a characteristic ferroelectric liquid crystal with a carbon number n = 7, S-2-methylbutyl 4-n-heptyloxybiphenyl-4'-carboxylate (C7). The results were compared with those of our recent work on S-2-methylbutyl 4-n-octanoyloxybiphenyl-4'-carboxylate (C8), with a carbon number n = 8. While the recrystallization and isotropic phase transitions exhibited a first-order nature in the $^1H$ NMR spin-lattice and spin-spin relaxation measurements, a second-order nature was shown at the Sm-A - Sm-$C^*$ liquid crystalline phase transition. A soft-mode anomaly arising from the tilt angle amplitude fluctuation of the director, of which only a hint had been noticed in the C8 system, was manifested in the C7 system at this transition.

치자 열매에서 항미생물 활성을 갖는 3,4-Dihydroxybenzoic Acid의 분리 (Isolation of 3,4-Dihydroxybenzoic Acid, Which Exhibits Antimicrobial Activity, from Fruits of Gardenia jasminoides Ellis)

  • 임철근;문제학;박근형
    • 한국식품과학회지
    • /
    • 제31권5호
    • /
    • pp.1386-1391
    • /
    • 1999
  • 치자(Gardenia jasminoides Ellis) 열매의 methanol추출물은 Gram양성 세균, Gram음성 세균, 효모 등의 미생물에 대하여 항미생물 활성을 보여, solvent fractionation, silica gel adsorption column chromatography, Sephadex LH-20 column chromatography, ODS column chromatography, HPLC등에 의해 얻어진 활성 물질을 MS, GC-MS, $^{1}H-NMR,\;^{13}C-NMR$ 그리고 2D-NMR 등의 기기 분석에 의해 3,4-dihydroxybenzoic acid는 동정하였다. 치자 열매에서 3,4-dihydroxybenzoic acid가 항미생물 활성물질로 분리 동정된 것은 처음으로 생각된다. 3,4-dihydroxybenzoic acid는 건조 치자열매에 g당 $32.7\;{\mu}g$ 정도 함유되어 있었다.

  • PDF

Detection of electromagnetic interference shielding effect of Hanji mixed with carbon nanotubes using nuclear magnetic resonance techniques

  • Byun, Young Seok;Chae, Shin Ae;Park, Geun Yeong;Lee, Haeseong;Han, Oc Hee
    • Carbon letters
    • /
    • 제27권
    • /
    • pp.90-97
    • /
    • 2018
  • Electromagnetic interference (EMI) shielding is an important issue in modern daily life due to the increasing prevalence of electronic devices and their compact design. This study estimated EMI-shielding effect (EMI-SE) of small ($8-14{\times}17mm$) Hanji (Korean traditional paper) doped with carbon nanotubes (CNTs) and compared to Hanji without CNT using $^2H$ (92.1 MHz) and $^{23}Na$ (158.7 MHz) nuclear magnetic resonance (NMR) peak area data obtained from 1 M NaCl in $D_2O$ samples in capillary tubes that were wrapped in the Hanji samples. The simpler method of using the variation of reflected power and tuning frequency by inserting the sample into an NMR coil was also tested at 242.9, 158.7, and 92.1 MHz. Overall, EMI shielding was relatively more effective at the higher frequencies. Our results validated that NMR methods to be useful to evaluate EMI-SE, particularly for small, flexible shielding materials, and demonstrated that EMI shielding by absorption is dominant in Hanji mixed with CNT.

A design study of a 4.7 T 85 mm low temperature superconductor magnet for a nuclear magnetic resonance spectrometer

  • Bae, Ryunjun;Lee, Jung Tae;Park, Jeonghwan;Choi, Kibum;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.24-29
    • /
    • 2022
  • One of the recent proposals with nuclear magnetic resonance (NMR) is a multi-bore NMR which consists of array of magnets which could present possibilities to quickly cope with pandemic virus by multiple inspection of virus samples. Low temperature superconductor (LTS) can be a candidate for mass production of the magnet due to its low price in fabrication as well as operation by applying the helium zero boil-off technology. However, training feature of LTS magnet still hinders the low cost operation due to multiple boil-offs during premature quenches. Thus in this paper, LTS magnet with low mechanical stress is designed targeting the "training-free" LTS magnet for mass production of magnet array for multi-bore NMR. A thorough process of an LTS magnet design is conducted, including the analyses as the followings: electromagnetics, mechanical stress, cryogenics, stability, and protection. The magnet specification was set to 4.7 T in a winding bore of 85 mm, corresponding to the MR frequency of 200 MHz. The stress level is tolerable with respect to the wire yield strength and epoxy crack where mechanical disturbance is less than the minimum quench energy.

Overhauser dynamic nuclear polarization for benchtop NMR system using a permanent magnet of 1.56 T

  • Lee, Yeon-seong;Lim, Duk-Young;Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제23권3호
    • /
    • pp.81-86
    • /
    • 2019
  • Overhauser dynamic nuclear polarization (O-DNP) has been an efficient method to boost the thermal nuclear polarization in liquids at room temperature. However, O-DNP for a benchtop NMR using a permanent magnet has remained unexplored yet. In this work, we report the development of an O-DNP system adopting a permanent magnet of 1.6 T. Q-band (~43 GHz) high-power amplifier produced 6 W microwave for saturation. Instead of resonator, we used an open-type antenna for the microwave irradiation. For several representative small molecules, we measured the concentration and frequency dependences of the enhancement factor. This work paves the way for the development of a benchtop DNP-NMR system overcoming its disadvantage of low quality signal when using a permanent magnet.

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • 한국자기공명학회논문지
    • /
    • 제23권1호
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

갈륨 신티그라피와 자기공명영상으로 진단한 근육 유육종증 (A Case of Muscular Sarcoidosis diagnosed by Gallium-67 Scintigraphy and Magnetic Resonance Imaging)

  • 손형선;김의녕
    • 대한핵의학회지
    • /
    • 제33권6호
    • /
    • pp.543-547
    • /
    • 1999
  • Gallium-67 scintigraphy is helpful in the assessment of active extrapulmonary sarcoidosis. Muscular involvement of sarcoidosis is often asymptomatic or nonspecific, and laboratory examinations do not provide convincing evidence of muscular involvement We report a case of muscular sarcoidosis, which was detected by gallium-67 scintigraphy. In a patient who was suffering from fever and arthralgia of knee joint, gallium-67 scintigraphy showed mediastinal and hilar involvement of sarcoidosis with unexpected extensive muscular uptake. Magenetic resonance imaging revealed the detailed depiction of intramuscular infiltration of sarcoid granuloma. Gallium-67 scintigraphy is useful in detecting inflammatory muscular involvement of sarcoidosis as well as other multiorgan involvement.

  • PDF

자기공명검층: 기본 이론 및 자료 측정 (A Review on nuclear magnetic resonance logging: fundamental theory and measurements)

  • 장재화;남명진
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.235-244
    • /
    • 2012
  • 석유탐사에서 자기공명검층은 저류층 내 유체의 양과 특성을 측정 및 평가 할 수 있는 물리검층 방법 중 하나로 평가되고 있다. 자기공명검층은 수소 원자의 자기모멘트와 외부 자기장을 이용하여 이 둘의 반응 즉, 분극과 이완을 측정, 분석하는 물리검층 방법이다. 측정된 자료는 저류층 내 유체의 수소밀도에 대한 정보와 감쇠 속도에 대한 정보를 포함 하고 있으며, 이를 바탕으로 적절한 자료 처리 과정을 거치면, 유체의 특성 및 유체의 양과 같은 저류층의 생산성과 관련된 중요한 정보를 취득할 수 있다. 뿐만 아니라 자기공명검층 결과를 이용한 투수성, 습윤성와 같은 생산공학적 측면의 해석방법에 대한 연구 또한 활발하게 진행되고 있다. 이 논문에서는 자기공명반응의 기본적인 이론과 자기공명검층의 역사 그리고 자기공명검층 장비를 통한 자료의 측정 원리에 대해 순서대로 알아보도록 하겠다. 또한 랜덤워크를 이용한 자기공명반응의 시뮬레이션에 대해서도 간략하게 소개하고자 한다.

Paraelectric-Ferroelectric Phase Transition of (NH4)2SO4 Single Crystals by 14N NMR

  • Lim, Ae Ran
    • 한국자기공명학회논문지
    • /
    • 제21권2호
    • /
    • pp.63-66
    • /
    • 2017
  • The $^{14}N$ NMR spectra for $(NH_4)_2SO_4$ crystals were obtained near the phase transition temperature $T_C=223K$, and were found to precisely reflect the symmetry change in the crystal at this first-order phase transition. Changes in the resonance frequencies near $T_C$ were attributed to the structural phase transition. In the ferroelectric and paraelectric phases, two inequivalent NH4 groups were distinguished in the $^{14}N$ NMR spectra. The two types, $NH_4$(1) and $NH_4$(2), have slightly different local environments. Consequently, we conclude that the phase transition is caused by the change in the environment of the $^{14}N$ nuclei in the $NH_4$ groups, rather than by the $SO_4$ groups.