• Title/Summary/Keyword: Nuclear localization

Search Result 308, Processing Time 0.022 seconds

Cytochemical Localization of Nuclear Actin of Sperm and Spermatids in Urechis unicinctus

  • Shin, Kil-Sang;Kim, Ho-Jin;Kwon, Hyuk-Jae;Kim, Wan-Jong
    • Animal cells and systems
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 2005
  • In this study, we found that sperm ball of Urechis unicinctus consisted of a somatic cell and spermatogenic cells. After separation from the sperm ball, individual spermatid floated freely in the coelomic fluid and differentiated into a mature sperm. Because of many nuclear vacuoles, spermatid nucleus was observed to be heterogeneous. Later, the spermatid nucleus condensed into the homogeneous round nucleus of the mature sperm. Perinuclear microtubules could be seen but did not seem to be organized into manchette microtubules. To understand the nature of nuclear condensation during spermiogenesis, the sperm and spermatids (spermiogenic cells) were treated with FITC-phalloidin, or anti-actin-FITC, or labeled with antiactin immunogold particles (AAIP; 10 nm) followed by transmission electron microscopy or confocal laser scanning microscopy. The anti-actin-FITC and FITC-phalloidin reactions occurred distinctly in the nuclei of both spermiogenic cells. FITC-phalloidin reacted more intensely with acrosomes. The AAIP were incorporated mainly into nuclei of both cells sometimes showing local distribution in the nucleus. Nuclear vacuoles of spermatids disappeared progressively with condensation of the nucleus, as the number of incorporated $AAIP/{\mu}m^2$ increased. These results suggest that nuclear actin microfilaments might be closely related to nuclear condensation.

Nanomedicine: Drug Delivery Systems and Nanoparticle Targeting (나노의학: 나노물질을 이용한 약물전달시스템과 나노입자의 표적화)

  • Youn, Hye-Won;Kang, Keon-Wook;Chung, June-Key;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.337-346
    • /
    • 2008
  • Applications of nanotechnology in the medical field have provided the fundamentals of tremendous improvement in precise diagnosis and customized therapy. Recent advances in nanomedicine have led to establish a new concept of theragnosis, which utilizes nanomedicines as a therapeutic and diagnostic tool at the same time. The development of high affinity nanoparticles with large surface area and functional groups multiplies diagnostic and therapeutic capacities. Considering the specific conditions related to the disease of individual patient, customized therapy requires the identification of disease target at the cellular and molecular level for reducing side effects and enhancing therapeutic efficiency. Well-designed nanoparticles can minimize unnecessary exposure of cytotoxic drugs and maximize targeted localization of administrated drugs. This review will focus on major pharmaceutical nanomaterials and nanoparticles as key components of designing and surface engineering for targeted theragnostic drug development.

Introduction of Vibration Evaluation for APR 1400 Reactor Coolant Pump Shaft (APR 1400급 원자로냉각재펌프의 회전체 진동평가에 관한 고찰)

  • Kim, Ik Joong;Lim, Do Hyun;Kim, Min Chul;Bang, Sang Youn
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.110-115
    • /
    • 2014
  • The nuclear power plant was launched by Kori unit 1 in 1978 years. Currently, 23 nuclear power plants have been operating in Korea since 1978 years. The localization was completed for most of the reactor facility from Hanbit(Youngkwang) unit 3&4. However, RCP(Reactor Coolant Pump) and MMIS(Man Machine Interface System) is an important technology that has been excluded from the scope of the technical transfer has been dependent on a specific overseas vendor. Recent success in RCP development through co-operation with government and industries. Developed RCP will be applied to Shin-Hanul unit 1&2 nuclear power plants. The RCP operates in high speed and high pressure condition and only rotating component in the NSSS(Nuclear Steam Supply System). Therefore, the problem of vibration has arisen caused by the hydraulic forces of the working fluid. These forces can influence on the stability characteristics for entire RCS(Reactor Coolant System) loop, and can act as significant destabilizing forces. In this study, vibration evaluation of the pump shaft of development RCP estimated under normal operation and over speed conditions. In order to predict the vibration characteristics and dynamic behavior, modal analysis, critical speed analysis and unbalance response spectrum analysis were performed.

  • PDF

Quantitative Assessment of Cerebral Perfusion Reserves Using Normalized Difference Ratio Image of Brain SPECT (뇌혈류 SPECT에서 정규화감산영상을 이용한 뇌혈류비축능의 정량적 평가에 관한 연구)

  • Lee, J.S.;Kwark, C.;Park, K.S.;Jeong, J.M.;Lee, D.S.;Chung, J.K.;Lee, M.C.;Koh, C.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.279-282
    • /
    • 1996
  • Sequential brain SPECT imaging has been used to assess the cerebral perfusion reserve(CPR) in cerebrovascular diseases(CVD). We have realized a parametric images of CPR using normalized difference ratio and deadtime correction. For the anatomical localization of CPR, the parametric images were registered to the contours of the cerebral regions using optimal threshold method. The parametric imags reflected the CPR more reliably and distinctively. We conclude that the qunatitative estimation of CPR using normalized difference ratio image could be useful for the diagnosis and assessment of postoperative prognosis in CVD.

  • PDF

The design of wall-climbing underwater robot system (수중 벽면 주행 기구의 설계)

  • 김병만;김경훈;박영수;박기용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.237-240
    • /
    • 1997
  • The design of underwater inspection robot system is presented. This robot system is designed for wall inspection in the nuclear plant facility. This paper describes the major components of the robot and its structures. This robot system is consisted of three parts : mechanical electrical and sensing pail. The main problem of designing mechanical part is to select the mechanism of driving. In this system the propeller driving mechanism is selected which can be move the robot continuously. For reducing the size of robot, we designed the CPU and motor controller board. The sensor system is consisted of two parts. One is environment monitoring part and the other is robot localization system.

  • PDF

Regulatory expression and cellular localization of doublecortin in the rat retina following ischemia-reperfusion injury

  • Gwon, Jae-Sung;Chun, Myung-Hoon;Kang, Wha-Sun
    • Animal cells and systems
    • /
    • v.15 no.2
    • /
    • pp.155-159
    • /
    • 2011
  • Doublecortin (DCX) is microtubule-associated protein and is required for neuronal migration, differentiation and plasticity. In the retina, it is highly expressed between embryonic day 18 (E18) and E20, and is poorly expressed postnatally. In this study, we investigated the expression and cellular localization of DCX in the rat retina following ischemia induced by transiently increasing the intraocular pressure. While DCX immunoreactivity in control retinas was restricted to the outer border of the inner nuclear layer, it appeared in horizontal cell somata and processes in affected retinas. Quantitative evaluation by immunoblotting confirmed that DCX expression continuously increased after ischemia-reperfusion and showed 370% of control protein levels at 4 weeks after ischemic insult. These results suggest that the DCX in horizontal cells might play a role in neurite remodeling or modulating other neurons in ischemic rat retinas.

Combined PET/CT in Oncology (종양핵의학에서 PET/CT의 역할)

  • Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.80-86
    • /
    • 2002
  • Presently, PET is widely used in oncology, but suffers from limitations of poor anatomical information. To compensate for this weakness, a combined PET/CT has been developed by Professor Townsend at the University of Pittsburgh Medical Center. The prototype was designed as PET and CT components combined serially in a gantry. The CT images provide not only accurate anatomical location of the lesions but also transmission map for attenuation correction. More than 300 cancer patients have been studied with the prototype of PET/CT since July, 1998. The PET/CT studies affected the managements in about $20{\sim}30%$ of cancer patients. These changes are a consequence of the more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake. Now a variety of combined PET/CT scanners with high-end PET and high-end CT components are commercially available. With the high speed of multi-slice helical CT, throughput of patient's increases compared to conventional PET. Although some problems (such as a discrepancy in breathing state between the two modalities) still remain, the role of PET/CT in oncology is very promising.

Quality Assurance and Performance Evaluation of PET/CT (핵의학 영상장비 PET/CT의 정도관리와 성능평가)

  • Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.137-144
    • /
    • 2008
  • Positron emission tomography-computed tomography (PET/CT) provides both functional and anatomical images of high quality non-invasively with better precision in localization than PET alone. Increase in the use of PET/CT, coupled with increasing concerns about the quality of medical services accrued the demands for accurate evaluation of system performance and quality assurance. Thus, well designed programs for performance evaluation and quality assurance are needed. Widely used protocols for performance evaluation of PET are the methods proposed by National Electrical Manufacturers Association (NEMA) in 1994 and 2001. In addition, in order to maintain high quality of PET/CT images, quality assurance programs including periodic (daily, monthly, and yearly). Therefore, in this article, the methods and present state of performance evaluation and quality assurance of PET/CT are reviewed.

Experience for development and capacity certification of safely relief valves (안전방출밸브 개발과 용량인증 사례)

  • Kim, Chil-Seong;No, Hui-Seon;Kim, Gang-Tae;Kim, Ji-Heon;Kim, Jong-Su
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.492-500
    • /
    • 2004
  • The purpose of this study is localization of safety relief valves fur Nuclear Service through technical development with overall design, fabrication, inspection, capacity certification test and functional qualification test of safety relief valves in accordance with KEPIC MN Code(or ASME Sec.III ). The safely relief valve is the important equipment used to protect the pressure vessel, the steam generator and the other pressure facility from overpressure by discharging the operating medium when the pressure of system is reaching the design pressure of the system. But we're depending on technology of the other country up to the present time. Because we don't have our own technologies, we have been spent the great time and money on installing and repairing safety relief valve at nuclear power plant. Therefore we have to achieve the development of safety relief valves for Nuclear Service with our own technologies.

  • PDF

Tc-99m MIBI and Tl-201 Uptake in a Thymic Carcinoma (악성 흉선종에서 관찰된 Tc-99m MIBI와 Tl-201의 섭취)

  • Hyun, In-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.260-261
    • /
    • 2003
  • Tc-99m methoxyisobutylisonitrile (MIBI) and Tl-201/technetium subtraction scintigraphy have been used for localization of abnormal parathyroid gland. The uptake mechanism of tracers has been postulated to be increased cellular density and vascularity, or dependent on the presence of mitochondria-rich cells. However, the uptake of these tracers was not specific for abnormal parathyroid gland. The author report a case of thymic carcinoma that would have been mistaken for carcinoma of parathyroid because of Tc-99m MIBI and Tl-201 uptake.