1 |
American College of Radiology. ACR technical standard for medical nuclear physics performance monitoring of PET imaging equipment. ACR technical standard(PET equiment):847-9, 2001
|
2 |
Buchert R, Bohuslavizki KH, Mester J, et al. Quality assurance in PET: Evaluation of the clinical relevance of detector defects, J Nucl Med 1999;10:1657-65
|
3 |
Philips Medical System. Gemini GXL performance test technical manual, Cleveland, Philips Medical Systems, 2005
|
4 |
International Electrotechnical Comission. International standard (IEC 1223-2-6). Evaluation and routine testing in medical imaging department - Part 2-6: Constancy test - X-ray equipment for computed tompgraphy International Electrotechnical Comission. 1994
|
5 |
Daube-Witherspoon M.E., Karp J.S, Casey M.E., et al. PET performance measurements using the NEMA NU 2-2001 standard. J Nucl Med 2002;43:1398-409
|
6 |
Siemens Medical Solutions. Installation manual biograph 6 Hi-Rez, Hofmann Estates. Siemens Medical Solutions., 2004
|
7 |
GE Medical Systems. Technical publication: AdvanceTM PET imaging system description and specification. Milwaukee, GE Medical Systems, 1994
|
8 |
Mawlawi O., Podoloff D.A., Kohlmyer S., et al. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. J Nucl Med 2004;45:1734-42
|
9 |
Lee JR, Choi Y, Choe YS, Lee KH, Kim SE, Shin SA, Kim BT. Performance measurements of positron emission tomography: An Investigation using general electric advanceTM. Korean J Nucl Med 1996;30:548-59
과학기술학회마을
|
10 |
Kim JS, Lee JS, Lee BI, Lee DS, Chung J-K, Lee MC. Performance characteristics of 3D GSO PET/CT scanner(Philips GEMINI PET/CT). Korean J Nucl Med 2004;38:318-24
과학기술학회마을
|
11 |
Wackers FJ 3rd. Intersocietal commission for the accreditation of nuclear medicine laboratories. Blueprint of the accreditation program of the intersocietal commission for the accreditation of nuclear medicine laboratories. J Nucl Cardiol 1999;6:372-4
DOI
ScienceOn
|
12 |
International Electrotechnical Comission. International standard (IEC 61675-1). Radionuclide imaging devices characteristics and test conditions. Part 1: Positron emission tomographs. International Electrotechnical Comission. 1998
|
13 |
AAPM publication. AAPM report no.39. Specification and acceptance testing of computed tomography scanners. 1993
|
14 |
National Electrical Manufacturers Association. NEMA Standard Publication NU 2-1994. Performance measurements of positron emission tomographs. National Electrical Manufacturers Association, 1994
|
15 |
National Electrical Manufacturers Association. NEMA Standard Publication NU 2-2001. Performance measurements of positron emission tomographs. National Electrical Manufacturers Association, 2001
|
16 |
MacFarlane CR. ACR Accreditation of Nuclear Medicine and PET Imaging Departments. J Nucl Med Technol 2006;34:18-24
|
17 |
Choi JG, Choi CW, Lee BI, Report of research service project (Research for actual conditions of quality assurance of imaging system in nuclear medicine). 식품의약청안정청. 2007
|
18 |
Philips Medical System. Gemini calibration technical manual for dual, 16 power, and GSL, Cleveland, Philips Medical Systems, 2006
|
19 |
Jeong HK, Kim HJ, Son HK, Bong JK, Jung HA, Jeon TJ, Kim JS, Lee JD, Yoo HS. Standard performance measurements of GE advance positron emission tomography. Korean J Nucl Med 2001;35: 100-12
과학기술학회마을
|
20 |
Katanick SL. Fundamentals of ICANL Accreditation. J Nucl Med Technol 2005;33:19-23
|
21 |
GE Medical Systems. Technical publication: Discovery LS PET CT combined PET and CT scanner operator's guide. Milwaukee, GE Medical Systems, 1994
|
22 |
Choi Y, Chung J-K, Report of research service project (Development of standard of evaluation of PET). 식품의약품안정청. 2003
|
23 |
American College of Radiology. ACR technical standard for medical nuclear physics performance monitoring of computed tompgraphy (CT) equipment. ACR technical standard(PET equiment):831-33, 2002
|
24 |
International Electrotechnical Comission. International standard (IEC 1223-3-5). Evaluation and routine testing in medical imaging department - Part 3-6: Acceptance tests - Imaging performance of computed tompgraphy X-ray equipment International Electrotechnical Comission. 2004
|
25 |
Siemens Medical Solutions. Operator's guide biograph 6 Hi-Rez, Hofmann Estates. Siemens Medical Solutions., 2004
|
26 |
Spinks T, Jones T, Heather J, et al. Quality control procedures in positron tomography. Eur J Nucl Med 1989;15:736-40
DOI
|
27 |
GE Medical Systems. DST PET-CT NEMA Test procedures. Applicable to Discovery ST. Milwaukee, GE Medical Systems, 2005
|
28 |
Kim JS, Lee JS, Lee DS, Chung J-K, Lee MC. Performance evaluation of Siemens CTI ECAT EXACT 47 scanner using NEMA NU2-2001. Korean J Nucl Med 2004;38:259-67
과학기술학회마을
|
29 |
International Electrotechnical Comission. International standard (IEC 1223-3-5). Evaluation and routine testing in medical imaging department - Part 3-5: Acceptance tests - Imaging performance of computed tompgraphy X-ray equipment International Electrotechnical Comission. 2004
|
30 |
Karp J.S., Daube-Witherspoon M.E., Hoffman E.J. et al, Performance standards in positron emission tomography. J Nucl Med 1991;32: 2342-50
|