• 제목/요약/키워드: Nuclear imaging

검색결과 1,320건 처리시간 0.022초

방사선 내부흡수선량의 의학적 적용 (Medical Application of Radiation Internal Dosimetry)

  • 김경민;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.164-171
    • /
    • 2008
  • Medical internal radiation dosimetry (MIRD) is an important part of nuclear medicine research field using therapeutic radioisotope. There have been many researches using MIRD for the development of new therapeutic approaches including radiopharmaceutical, clinical protocol, and imaging techniques. Recently, radionuclide therapy has been re-focused as new solution of intractable diseases, through to the advances of previous achievements. In this article, the basic concepts of radiation and internal radiation dosimetry are summarized to help understanding MIRD and its application to clinical application.

핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정 (Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction)

  • 김진수;이재성;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

도파민운반체 영상의 임상적 유용성 (Clinical Usefulness of Dopamine Transporter Imaging)

  • 김종민;김유경;김상은;전범석
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권2호
    • /
    • pp.152-157
    • /
    • 2007
  • Imaging of the dopamine transporter (DAT) provides a marker for the integrity of presynaptic nigrostriatal dopaminergic system. DAT density is reduced in Parkinson disease, multiple system atrophy, and progressive supranuclear palsy. In patients with suspicious parkinsonism, normal DAT imaging suggests an alternative diagnosis such as essential tremor, vascular parkinsonism, or drug-induced parkinsonism. DAT imaging is a useful tool to aid clinician's differential diagnosis in parkinsonism.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

핵의학 영상기기의 감마선 검출기 (Gamma-ray Detectors for Nuclear Medical Imaging Instruments)

  • 조규성
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.88-97
    • /
    • 2008
  • In this review paper, basic configurations of gamma detectors in SPECT and PET systems were reviewed together with key performance parameters of the imaging system, such as the detection efficiency, the spatial resolution, the contrast resolution, and the data acquisition time for quick understanding of the system-component relationship and future design of advanced systems. Also key elements of SPECT and PET detectors, such as collimators, gamma detectors were discussed in conjunction with their current and future trend. Especially development trend of new scintillation crystals, innovative silicon-based photo-sensors and futuristic room-temperature semiconductor detectors were reviewed for researchers who are interested in the development of future nuclear medical imaging instruments.

약물부하 검사법의 현재와 미래 (Current Trends and Future Development in Pharmacologic Stress Testing)

  • 배진호;이재태
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.107-113
    • /
    • 2005
  • Pharmacologic stress testing for myocardial perfusion imaging is a widely used noninvasive method for the evaluation of known or suspected coronary artery disease. The use of exercise for cardiac stress has been practiced for over 60 years and clinicians are familial with its using. However, there are inevitabe situations in which exorcise stress is inappropriate. A large number of patients with cardiac problems are unable to exercise to their full potential due to comorbidity such as osteoarthritis, vascular disease and pulmonary disease and a standard exercise stress test for myocardial perfusion imaging is suboptimal means for assessment of coronary artery disease. This problem has led to the development of the pharmacologic stress test and to a great increase in its popularity. All of the currently used pharmacologic agents have well-documented diagnostic value. This review deals the physiological actions, clinical protocols, safety, nuclear imaging applications of currently available stress agents and future development of new vasodilating agents.

Epidermal Growth factor 수용체 영상을 위한 방사성추적자 기술 (Radiotracer Methods for Targeted Imaging of the Epidermal Growth Factor Receptor)

  • 정경호;이경한
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권3호
    • /
    • pp.185-191
    • /
    • 2008
  • While indirect targeting strategies using reporter-genes are taking center stage in current molecular imaging research, another vital strategy has long involved direct imaging of specific receptors using radiolabeled ligands. Recently, there is renewal of immense interest in this area with particular attention to the epidermal growth factor receptor (EGFR), a transmembrane glycoprotein critically involved in the regulation of many cellular functions and malignancies. Recently, two novel classes of EGFR-targeting anticancer drugs have entered clinical trials with great expectations. These are monoclonal antibodies such as cetuximab that target the extracellular domain, and small molecule tyrosine kinase inhibitors such as gefitinib (lressa) and erlotinib (Tarceva) that target the catalytic domain of the receptor. However, early results have showed disappointing survival benefits, disclosing a major challenge for this therapeutic strategy; namely, the need to identify tumors that are most likely to respond to the agents. To address this important clinical issue, several noninvasive imaging techniques are under investigation including radiolabeled probes based on small molecule tyrosine kinase inhibitors, anti-EGFR antibodies, and EGF peptides. This review describes the current status, limitations, and future prospects in the development of radiotracer methods for EGFR imaging.

뇌 신경물질 운반체 영상용 방사성의약품 (Radiopharmaceuticals for Neurotransmitter Imaging)

  • 오승준
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권2호
    • /
    • pp.118-131
    • /
    • 2007
  • Neurotransmitter imaging with radiopharmaceuticals plays major role for understanding of neurological and psychiatric disorders such as Parkinson's disease and depression. Radiopharmaceuticals for neurotransmitter imaging can be divided to dopamine transporter imaging radiopharmaceuticals and serotonin trnasporter imaging radiopharmaceuticals. Many kinds of new dopamine transporter imaging radiopharmcaeuticals has a tropane ring and they showed different biological properties according to the substituted functional group on tropane ring. After the first clinical trials with $[^{123}I]{\beta}-CIT$, alkyl chain substituent introduced to tropane ring amine to decrease time for imaging acquisition and to increase selectivity. From these results, $[^{123}I]PE2I$, [18F]FE-CNT, $[^{123}I]FP-CIT$ and $[^{18}F]FP-CIT$ were developed and they showed high uptake on the dopamine transporter rich regions and fast peak uptake equilibrium time within 4 hours after injection. $[^{11}C]McN$ 5652 was developed for serotonin trnasporter imaging but this compound showed slow kinetics and high background radioactivity. To overcome these problems, new diarylsulfide backbone derivatives such as ADAM, ODAM, AFM, and DASB were developed. In these candidates, $[^{11}C]AFM$ and $[^{11}C]DASB$ showed high binding affinity to serotonin transporter and fast in vivo kinetics. This paper gives an overview of current status on dopamine and serotonin transporter imaging radiopharmaceuitcals and the development of new lead compounds as potential radiopharmaceuticals by medicinal chemistry.

핵의학 영상기기의 최근 진보 (Recent Advances in Nuclear Medicine Imaging Instrumentation)

  • 정진호;최용;홍기조;민병준;호위;강지훈
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.