Abstract
In this review paper, basic configurations of gamma detectors in SPECT and PET systems were reviewed together with key performance parameters of the imaging system, such as the detection efficiency, the spatial resolution, the contrast resolution, and the data acquisition time for quick understanding of the system-component relationship and future design of advanced systems. Also key elements of SPECT and PET detectors, such as collimators, gamma detectors were discussed in conjunction with their current and future trend. Especially development trend of new scintillation crystals, innovative silicon-based photo-sensors and futuristic room-temperature semiconductor detectors were reviewed for researchers who are interested in the development of future nuclear medical imaging instruments.
Keywords
SPECT; PET; collimator; scintillator; PM tube; APD; Si PM; CZT;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Anger HO. Scintillation Camera. Rev Sci Inst 1958;29:27-33   DOI
2 Feinmore EE. Coded aperture imaging: predicted performance of uniformly redundant arrays. Applied Optics 1987:17:3562-70   DOI
3 Paulus MJ, Rochelle JM, Binkley DM. Comparison of the Beveled- Edge and Reach-Through APD Structures for PET Applications. Proc IEEE Nucl Sci Symp 1995;1864-8
4 Moses WW. Trends in PET imaging. Nucl Instr Methds Phys A 2001;471:209-14   DOI   ScienceOn
5 Knoll GF. Radiation Detection and Measurement. 3rd ed. John Wiley and Sons Inc; 2000. p. 357, p. 483, p. 489
6 Knoll GF. Radiation Detection and Measurement. 3rd ed. John Wiley and Sons Inc; 2000. p. 234
7 Fiorini C, Bellini M, Gola A, Longoni A, Perotti F, Lechner P, et al. A Monilithic Array of 77 Silicon Drift Detectors for X-Ray Spectroscopy and Gamma-Ray Imaging Applications. IEEE Trans Nucl Sci 2005;52:1165-70   DOI   ScienceOn
8 Christian PE, Bernier DR, Langan JK. Nuclear Medicine and PET. 5th ed. Missouri: Mosby; 2004. p. 66
9 Eisen Y, Shor A, Mardor I. CdTe and CdZnTe X-Ray and Gamma- Ray Detectors for Imaging Systems. IEEE Trans Nucl Sci 2004; 51:1191-8   DOI   ScienceOn