• 제목/요약/키워드: Nuclear R&D system

Search Result 177, Processing Time 0.023 seconds

A case Study of 3D Model Application for Combining Nuclear Power Industry with Virtual Reality Technology (원전 산업과 가상현실기술 접목을 위한 3D 모델 원전 적용사례 연구)

  • Lim, Byung-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.224-225
    • /
    • 2019
  • Virtual reality technology can be defined as human-computer interface that makes virtual place of specific environments or situation is an interactive computer-generated experience taking place within a simulated environment. In order to combine virtual reality technology of domestic nuclear power industry, the R&D Project has been developing a virtual/augment reality system for nuclear power plant from April 2018 to March 2021. To effectively apply virtual reality technology of domestic nuclear industry, it is necessary to build virtual space similar to real environment. Therefore, This study is analysed 3d model status for nuclear power plant during the life-cycle, and suggested a method to build 3D cad model close to real environment.

  • PDF

Teleoperation R&D activities in korean nuclear waste program

  • Bum, T.J.;Jung, W.T.;Lee, J.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.795-798
    • /
    • 1989
  • This paper presents some results of teleoperation R&D activities for radioactive work. Heavy power manipulator feature is integrated with vision system implementation of advanced type and tool adaptation to hand gripper. Some assodiated te datth activities of interests to the teleoperation and future directions are also presented.

  • PDF

ON-LINE CALCULATION OF 3-D POWER DISTRIBUTION

  • Park, Y. H.;W. K. In;Park, J. R.;Lee, C. C.;G. S. Auh
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.459-464
    • /
    • 1996
  • The 3-D power distribution synthesis scheme was implemented in Totally Integrated Core Operation Monitoring System (TICOMS), which is under development as the next generation core monitoring system. The on-line 3-D core power distribution obtained from the measured fixed incore detector readings is used to construct the hot pin power as well as the core average axial power distribution. The core average axial power distribution and the hot pin power of TICOMS were compared with those of the current digital on-line core monitoring system, COLSS, which construct the core average axial power distribution and the pseudo hot pin power. The comparison shows that TICOMS results in the slightly more accurate core average axial power distribution and the less conservative hot pin power. Therefore, these results increased the core operating margins. In addition, the on-line 3-D power distribution is expected to be very useful for the core operation in the future.

  • PDF

Calculation of NMR Shift in Paramagnetic System When the Threefold Axis is Chosen as the Quantization Axis (Ⅰ). The NMR Shift for a 3d$^1$ System in a Strong Crystal Field of Octahedral Symmetry

  • Ahn, Sang-woon;Park, Euisuh;Lee, Kee-Hag
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.3
    • /
    • pp.103-114
    • /
    • 1983
  • The NMR shift arising from the electron angular momentum and the electron spin dipolar-nuclear spin angular momentum interaction has been examined for a $3d_1$ system in a strong octahedral crystal field when the threefold axis is chosen as the quantization axis. To investigate the NMR shift in this situation, first, we have extended the evaluation of the hyperfine integrals to any pairs of 3d orbitals adopting a general method which is applicable to a general vector R, pointing in arbitrary direction in space. Secondly, a general expression using a nonmultipole technique is derived for the NMR shift resulting from the electron angular momentum and the electron spin dipolar-nuclear spin angular momentum interactions. From this expression all the multipolar terms are determined. ${\Delta}B/B$ for the $3d_1$ system in this case is compared with that for the 3d1 system when the z axis is chosen as the quantization axis. When we choose the threefold axis as the quantization axis, it is found that along the , and axes, ${\Delta}B/B$ values are significantly different from each other and along the , <-1-1-1>, <-11-1>, , <-1-11>, , and <-111> axes, ${\Delta}B/B$ values are however the same. We also find that the 1/R7 term contributes dominantly to the NMR shift for all values of R. When 1/$R^5$ term is included, there is good agreement between the exact solution and the multipolar terms when $R\; {\leqslant}\;0.35\;nm.$.

Calculation of the NMR Chemical Shift for a 3d$^2$ System in a Strong Crystal Field of Octahedral Symmetry

  • Ahn, Sang-Woon;Kim, Dong-Hee;Park, Eui-Suh
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.63-67
    • /
    • 1985
  • The NMR chemical shift arising from 3d electron spin dipolar nuclear spin angular momentum interactions for a 3d$^2$ system in a strong crystal field environment of octahedral symmetry has been investigated when the fourfold axis is chosen to be our axis of quantization. The NMR shift is separated into the contribution of 1/R$^5$ and 1/R$^7$ terms. A comparision of the multipolar terms with nonmultipolar results shows that the 1/R$^5$ term contributes dominantly to the NMR shift and there is in good agreement between the exact solution and the multipolar results when R ${\ge}$ 0.25. A temperature dependence analysis may lead to the results that the 1/T$^2$ term has the dominant contribution to the NMR shift for a paramagnetic 3d$^2$ system but the contribution of the 1/T term may not be negligible.

Calculation of NMR Shift in Paramagnetic System when the Threefold Axis is Chosen as the Quantization Axis (Ⅲ). The NMR Shift for 3d$^2$ System in a Strong Crystal Field of Octahedral Symmetry

  • Sang Woon Ahn;Se Woong Oh;Kee Hag Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.3
    • /
    • pp.93-97
    • /
    • 1984
  • A general expression using the nonmultipole expansion method is derived for the NMR shift arising from 3d electron angular momentum and the 3d electron spin dipolar-nuclear spin angular momentum interactions for a 3$d^2$ system in a strong crystal field environment of octahedral symmetry when the threefold axis is chosen as the quantization axis. The NMR shift is separated to the contribution of constant, $1/R^5\;and\;1/R^7$ terms and compared with the multipolar terms. We find that $1/R^5$ term contributes dominantly to the NMR shift but the contribution of $1/R^7$ term may not be negligible. It is also found that the exact values of the NMR shift are in agreement with the multipolar results for distances larger than 0.35 nm.

NMR Chemical Shift for 4d$^n$ System (Ⅱ). Calculation of the Pseudo Contact Shift for a 4d$^1$ System in a Strong Crystal Field Environment of Octahedral Symmetry

  • Sang-woon Ahn;Se-Woong Oh;Eui-suh Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.2
    • /
    • pp.64-67
    • /
    • 1983
  • NMR shift arising from the electron orbital angular momentum and the electron spin dipolar-nuclear spin angular momentum interactions has been investigated for a $4d^{1}$ system in a strong crystal field of octahedral symmetry. To examine the NMR shif for a $4d^{1}$ system in a strong crystal field of octahedral symmetry, we derive a general expression for ${\Delta}$B/B using a nonmultipole expansion technique. From this expression all the multipolar terms are determined. For the $4d^{1}$ system in a strong crystal field of octahedral symmetry the exact solution for NMR shift, ${\Delta}$B, is compared with the multipolar results. ${\Delta}$B/B for the $4d^{1}$ system is also compared with that for the $3d^{1}$ system. It is found that the $1/R^{7}$ term contributes dominantly to the NMR shift. However, there is good agreement between the nonmultipole and multipolar results for R-values larger than 0.2 nm for the $4d^{1}$ system but for R-values larger than 0.4 nm for the $3d^{1}$ system.

Building Transparency on the Total System Performance Assessment of Radioactive Repository through the Development of the Cyber R&D Platform; Application for Development of Scenario and Input of TSPA Data through QA Procedures (Cyber R&D Platform개발을 통한 방사성폐기물 처분종합성능평가(TSPA) 투명성 증진에 관한 연구; 시나리오 도출 과정과 TSPA 데이터 입력에서의 품질보증 적용 사례)

  • Seo, Eun-Jin;Hwang, Yong-Soo;Kang, Chul-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.65-75
    • /
    • 2006
  • Transparency on the Total System Performance Assessment (TSPA) is the key issue to enhance the public acceptance for a radioactive repository. To approve it, all performances on TSPA through Quality Assurance is necessary. The integrated Cyber R&D Platform is developed by KAERI using the T2R3 principles applicable for five major steps : planning, research work, documentation, and internal & external audits in R&D's. The proposed system is implemented in the web-based system so that all participants in TSPA are able to access the system. It is composed of three sub-systems; FEAS (FEp to Assessment through Scenario development) showing systematic approach from the FEPs to Assessment methods flow chart, PAID (Performance Assessment Input Databases) being designed to easily search and review field data for TSPA and QA system containing the administrative system for QA on five key steps in R&D's in addition to approval and disapproval processes, corrective actions, and permanent record keeping. All information being recorded in QA system through T2R3 principles is integrated into Cyber R&D Platform so that every data in the system can be checked whenever necessary. Throughout the next phase R&D, Cyber R&D Platform will be connected with the assessment tool for TSPA so that it will be expected to search the whole information in one unified system.

  • PDF

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

Verification of SARAX code system in the reactor core transient calculation based on the simplified EBR-II benchmark

  • Jia, Xiaoqian;Zheng, Youqi;Du, Xianna;Wang, Yongping;Chen, Jianda
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1813-1824
    • /
    • 2022
  • This paper shows the verification work of SARAX code system in the reactor core transient calculation based on the simplified EBR-II Benchmark. The SARAX code system is an analysis package developed by Xi'an Jiaotong University and aims at the advanced reactor R&D. In this work, a neutron-photon coupled power calculation model and a spatial-dependent reactivity feedback model were introduced. To verify the models used in SARAX, the EBR-II SHRT-45R test was simplified to an ULOF transient with an input flowrate change curve by fitting from reference. With the neutron-photon coupled power calculation model, SARAX gave close results in both power fraction and peak power prediction to the reference results. The location of the hottest assembly from SARAX and reference are the same and the relative power deviation of the hottest assembly is 2.6%. As for transient analysis, compared with experimental results and other calculated results, SARAX presents coincident results both in trend and absolute value. The minimum value of core net reactivity during the transient agreed well with the reported results, which ranged from -0.3$ to -0.35$. The results verify the models in SARAX, which are correct and able to simulate the in-core transient with reliable accuracy.