• Title/Summary/Keyword: Ns-2

Search Result 1,725, Processing Time 0.038 seconds

Exploitation of Auxiliary Motion Vector in Video Coding for Robust Transmission over Internet (화상통신에서의 오류전파 제어를 위한 보조모션벡터 코딩 기법)

  • Lee, Joo-Kyong;Choi, Tae-Uk;Chung, Ki-Dong
    • The KIPS Transactions:PartB
    • /
    • v.9B no.5
    • /
    • pp.571-578
    • /
    • 2002
  • In this paper, we propose a video sequence coding scheme called AMV (Auxiliary Motion Vector) to minimize error propagation caused by transmission errors over the Internet. Unlike the conventional coding schemes the AMY coder, for a macroblock in a frame, selects two best matching blocks among several preceding frames. The best matching block, called a primary block, is used for motion compensation of the destination macroblock. The other block, called an auxiliary block, replaces the primary block in case of its loss at the decoder. When a primary block is corrupted or lost during transmission, the decoder can efficiently and simply suppress error propagation to the subsequent frames by replacing the block with an auxiliary block. This scheme has an advantage of reducing both the number and the impact of error propagations. We implemented the proposed coder by modifying H.263 standard coding and evaluated the performance of our proposed scheme in the simulation. The simulation results show that AMV coder is more efficient than the H.263 baseline coder at the high packet loss rate.

Congestion Degree Based Available Bandwidth Estimation Method for Enhancement of UDT Fairness (UDT 플로우 간 공평성 향상을 위한 혼잡도 기반의 가용대역폭 추정 기법)

  • Park, Jongseon;Jang, Hyunhee;Cho, Gihwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.7
    • /
    • pp.63-73
    • /
    • 2015
  • In the end to end data transfer protocols, it is very important to correctly estimate available bandwidth. In UDT (UDP based Data Transfer), receiver estimates the MTR (Maximum Transfer Rate) of the current link using pair packets transmitted periodically from sender and, then sender finally decides the MTR through EWMA (Exponential Weighted Moving Average) algorithm. Here, MTR has to be exactly estimated because available bandwidth is calculated with difference of MTR and current transfer rate. However, when network is congested due to traffic load and where competing flows are coexisted, it bring about a severe fairness problem. This paper proposes a congestion degree based MTR estimation algorithm. Here, the congestion degree stands a relative index for current congestion status on bottleneck link, which is calculated with arriving intervals of a pair packets. The algorithm try to more classify depending on the congestion degree to estimate more actual available bandwidth. With the network simulation results, our proposed method showed that the fairness problem among the competing flows is significantly resolved in comparison with that of UDT.

Molecular epidemiology of Aleutian mink disease virus causing outbreaks in mink farms from Southwestern Europe: a retrospective study from 2012 to 2019

  • Prieto, Alberto;Fernandez-Antonio, Ricardo;Lopez-Lorenzo, Gonzalo;Diaz-Cao, Jose Manuel;Lopez-Novo, Cynthia;Remesar, Susana;Panadero, Rosario;Diaz, Pablo;Morrondo, Patrocinio;Diez-Banos, Pablo;Fernandez, Gonzalo
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.65.1-65.13
    • /
    • 2020
  • Background: Aleutian mink disease virus (AMDV) causes major economic losses in fur-bearing animal production. The control of most AMDV outbreaks is complex due to the difficulties of establishing the source of infection based only on the available on-farm epidemiological data. In this sense, phylogenetic analysis of the strains present in a farm may help elucidate the origin of the infection and improve the control and biosecurity measures. Objectives: This study had the following aims: characterize the AMDV strains from most outbreaks produced at Spanish farms between 2012-2019 at the molecular level, and assess the utility of the combined use of molecular and epidemiological data to track the possible routes of infection. Methods: Thirty-seven strains from 17 farms were partially sequenced for the NS1 and VP2 genes and analyzed phylogenetically with other strains described worldwide. Results: Spanish AMDV strains are clustered in four major clades that generally show a good geographical correlation, confirming that most had been established in Spain a long time ago. The combined study of phylogenetic results and epidemiological information of each farm suggests that most of the AMDV outbreaks since 2012 had been produced by within-farm reservoirs, while a few of them may have been due to the introduction of the virus through international trade. Conclusions: The combination of phylogenetic inference, together with epidemiological data, helps assess the possible origin of AMDV infections in mink farms and improving the control and prevention of this disease.

Artificial Neural Network with Firefly Algorithm-Based Collaborative Spectrum Sensing in Cognitive Radio Networks

  • Velmurugan., S;P. Ezhumalai;E.A. Mary Anita
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.7
    • /
    • pp.1951-1975
    • /
    • 2023
  • Recent advances in Cognitive Radio Networks (CRN) have elevated them to the status of a critical instrument for overcoming spectrum limits and achieving severe future wireless communication requirements. Collaborative spectrum sensing is presented for efficient channel selection because spectrum sensing is an essential part of CRNs. This study presents an innovative cooperative spectrum sensing (CSS) model that is built on the Firefly Algorithm (FA), as well as machine learning artificial neural networks (ANN). This system makes use of user grouping strategies to improve detection performance dramatically while lowering collaboration costs. Cooperative sensing wasn't used until after cognitive radio users had been correctly identified using energy data samples and an ANN model. Cooperative sensing strategies produce a user base that is either secure, requires less effort, or is faultless. The suggested method's purpose is to choose the best transmission channel. Clustering is utilized by the suggested ANN-FA model to reduce spectrum sensing inaccuracy. The transmission channel that has the highest weight is chosen by employing the method that has been provided for computing channel weight. The proposed ANN-FA model computes channel weight based on three sets of input parameters: PU utilization, CR count, and channel capacity. Using an improved evolutionary algorithm, the key principles of the ANN-FA scheme are optimized to boost the overall efficiency of the CRN channel selection technique. This study proposes the Artificial Neural Network with Firefly Algorithm (ANN-FA) for cognitive radio networks to overcome the obstacles. This proposed work focuses primarily on sensing the optimal secondary user channel and reducing the spectrum handoff delay in wireless networks. Several benchmark functions are utilized We analyze the efficacy of this innovative strategy by evaluating its performance. The performance of ANN-FA is 22.72 percent more robust and effective than that of the other metaheuristic algorithm, according to experimental findings. The proposed ANN-FA model is simulated using the NS2 simulator, The results are evaluated in terms of average interference ratio, spectrum opportunity utilization, three metrics are measured: packet delivery ratio (PDR), end-to-end delay, and end-to-average throughput for a variety of different CRs found in the network.

Comparing Prediction Uncertainty Analysis Techniques of SWAT Simulated Streamflow Applied to Chungju Dam Watershed (충주댐 유역의 유출량에 대한 SWAT 모형의 예측 불확실성 분석 기법 비교)

  • Joh, Hyung-Kyung;Park, Jong-Yoon;Jang, Cheol-Hee;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.861-874
    • /
    • 2012
  • To fulfill applicability of Soil and Water Assessment Tool (SWAT) model, it is important that this model passes through a careful calibration and uncertainty analysis. In recent years, many researchers have come up with various uncertainty analysis techniques for SWAT model. To determine the differences and similarities of typical techniques, we applied three uncertainty analysis procedures to Chungju Dam watershed (6,581.1 $km^2$) of South Korea included in SWAT-Calibration Uncertainty Program (SWAT-CUP): Sequential Uncertainty FItting algorithm ver.2 (SUFI2), Generalized Likelihood Uncertainty Estimation (GLUE), Parameter Solution (ParaSol). As a result, there was no significant difference in the objective function values between SUFI2 and GLUE algorithms. However, ParaSol algorithm shows the worst objective functions, and considerable divergence was also showed in 95PPU bands with each other. The p-factor and r-factor appeared from 0.02 to 0.79 and 0.03 to 0.52 differences in streamflow respectively. In general, the ParaSol algorithm showed the lowest p-factor and r-factor, SUFI2 algorithm was the highest in the p-factor and r-factor. Therefore, in the SWAT model calibration and uncertainty analysis of the automatic methods, we suggest the calibration methods considering p-factor and r-factor. The p-factor means the percentage of observations covered by 95PPU (95 Percent Prediction Uncertainty) band, and r-factor is the average thickness of the 95PPU band.

Fluid Inclusion Studies on the Wolak Tungsten-Molybdenum Deposits, Korea (월악 중석-몰리브덴 광상의 유체포유물 연구)

  • Lee, In Sung;Park, Hee-In
    • Economic and Environmental Geology
    • /
    • v.15 no.1
    • /
    • pp.17-32
    • /
    • 1982
  • The Wolak tungsten-molybdenum deposits are tungsten-molybdenum bearing quartz veins which filled the fractures in Pre-Cambrian pebble-bearing calcareous hornfels, hornfels and Cretaceous granite. There are two vein groups in this mine, Dongsan vein group in the west and Kwangcheon vein group in the east. The ore minerals are wolframite, scheelite, molybdenite, native bismuth, bismuthinite, pyrite, arsenopyrite, chalcopyrite, cubanite, stannite, pyrrhotite, sphalerite, galena, marcasite, Pb-Bi sulfosalt and ilmenite. Quartz, calcite, beryl, fluorite, muscovite, rhodochrosite and siderite are gangue minerals. Fluid inclusion studies were carried out for the quartz, beryl, scheelite, early and late fluorite. Fluid inclusion studies reveal that liquid-gas inclusions are most common and occur in all of the minerals examined. Filling degree of the inclusions in the late fluorite is much higher than that of the inclusions in quartz and early fluorite. Liquid $CO_2$ bearing liquid-gas inclusions occur in quartz and early fluorite. Liquid, gas and solid phase inclusions occur in quartz, beryl and scheelite. Salinities of inclusions in quartz and beryl from Dongsan vein group range from 3.9 to 8.0, from 5.3 to 7.7 wt.% NaCl equivalent respectively. Salinities in the late fluorite range from 1.5 to 3.2 wt.% NaCl equivalent. In Kwangcheon vein group salinities range from 3.9 to 9.6 wt.% NaCl equivalent in quartz, from 2.8 to 7.3 wt.% NaCl equivalent in early fluorite, from 1.3 to 1.5 wt.% NaCl equivalent in late fluorite. Homogenization temperatures of inclusions range from $239^{\circ}$ to higher than $360^{\circ}C$ in quartz, over $360^{\circ}C$ in scheelite, from $288^{\circ}C$ to higher than $360^{\circ}C$ in beryl, and from $159^{\circ}$ to $202^{\circ}C$ in late fluorite of the Dongsan vein group. In Kwangcheon vein group, homo genization temperatures of inclusions range from $240^{\circ}C$ to higher than $360^{\circ}C$ in quartz and from $240^{\circ}$ to $328^{\circ}C$ in early fluorite. As a whole, in Dongsan and Kwangcheon vein groups it seems that there are no distinct differences in mineralogy, salinities and homogenization temperatures. No distinct variations in homogenization temperatures are revealed through about 300 m vertically in both district. The faint trend of increase in salinities in the lower level can be detected. The salinity, $CO_2$ content and the temperature of ore fluid were much higher in the early vein stage and then dropped off in the late stage of mineralization as represented by the quartz and fluorite inclusion data.

  • PDF

Risk Factors for the First-Year Relapse in Children with Nephrotic Syndrome (신증후군 환아에서 1년내 재발과 관련된 위험 요인)

  • Shin, Hye Kyoung;Kim, Ji Hee;Yoo, Kee Hwan;Hong, Young Sook;Lee, Joo Won;Kim, Soon Kyum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.9
    • /
    • pp.889-892
    • /
    • 2003
  • Purpose : This study aimed to evaluate risk factors of the first year relapse in children with nephrotic syndrome(NS) without the need for biopsy. Methods : We reviewed, retrospectively, 78 children diagnosed with steroid responsive nephrotic syndrome between July 1997 and June 2002. Median years to follow up were 4.4 years(range : 1-5 years). We divided the patients into two groups(group I : primary responders with no relapse or with only two relapses in the first year after initial response; group II : initial steroid responders with three or more relapses within the first year). We retrospectively reviewed and compared variables - sex, onset age, serum albumin, serum cholesterol, 24 hours urinary protein, creatinine clearance(Ccr), presence of hematuria and hypertension(HTN), and days from initial attack to remission. Results : Of 78 patients(male : 61(78.2%), female : 17(21.8%), age range 1.1 years to 14 years, median $5.1{\pm}3.0years$), 47(60.3%) were in group I and 31(39.7%) were in group II. There were no statistically significant differences in sex, serum albumin, serum cholesterol, 24 hours urinary protein, Ccr, presence of hematuria or HTN. The median age of onset showed no statistical difference between the two groups. However, if the patients are dividing into two groups according to the age of onset of three-years, patients theree yrs old or less fit into group II, as opposed to patients older than three yrs in age(63.2% vs. 32.2%, P<0.05). The days from initial attack to remission was longer in group II($12.9{\pm}0.5$ vs. $16.2{\pm}1.1$, P<0.05). Conclusion : We may conclude that the age of onset of three yrs old or less, and the longer time remission to initial steroid therapy, are risk factors of the first year relapse.

Endoscopic Radial Artery Harvest: Techniques & Results (내시경을 이용한 요골동맥 수확법의 수술 방법과 결과)

  • Jeong, Young-Kyun;Lee, Jong-Tae;Cho, Jun-Yong;Kim, Kyu-Tae;Chang, Bong-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.35-41
    • /
    • 2006
  • Background: The radial arteries are being used more often for coronary artery bypass grafting, We tried to the endoscopic radial artery harvest to reduce the cosmetic problems and neurologic complications of the conventional open harvesting and report the techniques and early results. Material and Method: The 86 patients underwent coronary artery bypass grafting between May 2003 and April 2005 had their nondominant radial artery endoscopically removed through a 2 cm incision at the wrist. The radial pedicle was dissected and was divided at antecubial area through a 5 mm counterincision. Result: The 23 patients complained of neuralgias on territory of superficial raidal none but no one complained of neuralgias on territory of lateral antebrachial cutaneous none. There was no functional impairment of the hand. There was no wound complication except a localized hematoma. All patients were contacted by telephone after postoperative 7.9$\pm$3.6 months. The 4 patients still complained of neuralgia. All the patients were satisfied with the aesthetics of the wounds. The multidetectional tomography was done on the 66 patients for the estimation of early patency of radial artery. There were 2 cases of stenosis and a case of occlusion. Conclusion: Endoscopic radial artery harvest had no functional impairment of the hand, lesser rate of neurologic complications and outstanding aesthetics. The results of early patency of the radial artery was similar to conventional methods. Therefore, we think that endoscopic radial artery harvest is the optimal procedure.

Relationship Between Adenosine-Induced ST Segment Depression During $^{99m}Tc$-MIBI Scintigraphy and The Severity of Coronary Artery Disease (Adenosine 부하 $^{99m}Tc$-MIBI 심근 관류스캔도중 나타나는 ST절 하강과 관상동맥 질환의 중증도와의 관계)

  • Cho, Jung-Ah;Choi, Chung-Il;Kwak, Dong-Suk;Kim, Jeong-Gyun;Bae, Sun-Kun;Chung, Byung-Cheon;Lee, Jae-Tae;Lee, Kyu-Bo;Kang, Seung-Wan;Woo, Eon-Jo;Kim, Sin-Woo;Sohn, Sang-Kyun;Chae, Shung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 1994
  • Pharmacologic coronary vasodilation in conjunction with myocardial perfusion scintigraphy has become an alternative to dynamic exercise test for the diagnosis and risk stratification of coronary artery disease, especially in patients who are unable to perform adequate exercise. Dipyridamole and adenosine have been used for pharmacologic stress testing with myocardial perfusion imaging. Adenosine is a potent coronary vasodilator with rapid onset of action, short half-life, near maximal coronary vasodilation and less serious side effects. ST segment depression has been reported in about 7-15% of patients with coronary artery disease receiving dipyridamole in conjunction with myocardial perfusion imaging. The exact cause and clinical significance are not known. In order to evaluate the relationship between adenosine-induced ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy and the severity of coronary artery disease, we performed $^{99m}Tc$-MIBI imaging after intravenous Infusion of adenosine In 120 patients with suspected coronary artery disease. Of the 120 patients, 28 also performed coronary angiography. There were 24 patients with ST segment depression during $^{99m}Tc$-MIBI scintigraphy and 96 patients without ST segment depression. Adenosine was infused Intravenously at a dose of 0.14mg/kg per minute lot 6minutes and $^{99m}Tc$-MIBI was injected at 3 minute. We then com-pared the hemodynamic changes, side effects, scintigraphic and angiographic findings. Heart rate increased $90{\pm}19$ beats/minute in the group with ST depression compared with $80{\pm}16$ beats/minute in the group without ST depression(p<0.05). Baseline systolic blood pressure was significantly higher in the group with ST depression($152{\pm}27$ mmHg) than in the group without 57 depression($140{\pm}21$mmHg, p<0.05). Double product at baseline($10.90{\pm}2.77$ versus $9.55{\pm}2.34\;beats/minute{\times}mmHg$) and during adenosine infusion($12.72{\pm}3.89$ versus $10.83{\pm}2.98\;beats/minute{\times}mmHg$) were significantly higher in the group with ST depression(p<0.05). The incidence of anginal chest pain was also significantly higher in the group with ST depression(ST versus 29%, p<0.0001). The $^{99m}Tc$-MIBI images were abnormal in 23(96%) patients with ST segment depression and 66(69%) patients without ST segment depression(p<0.05). In patients with ST segment depression, there were more reversible perfusion defects than in patients without ST segment depression(83 versus 55%, p<0.05). The number of abnormal segments were significantly higher in the group with ST depression($3.05{\pm}2.01$ versus $1.51{\pm}1.45$, p<0.005). In patients with ST segment depression, there were more segments of reversible perfusion defects than in patients without segment depression($2.15{\pm}2.11$ versus $0.89{\pm}1.24$, p<0.05). There were no differences in the angiographic severity by vessel(p ; NS). We concluded that ST segment depression during $^{99m}Tc$-MIBI myocardial perfusion scintigraphy with Intravenous adenosine is related to the severity of coronary artery disease.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.