• Title/Summary/Keyword: Novel phenomena

Search Result 144, Processing Time 0.028 seconds

TOWARD MECHANISTIC MODELING OF BOILING HEAT TRANSFER

  • Podowski, Michael Z.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.889-896
    • /
    • 2012
  • Recent progress in the computational fluid dynamics methods of two- and multiphase phase flows has already started opening up new exciting possibilities for using complete multidimensional models to simulate boiling systems. Combining this new theoretical and computational approach with novel experimental methods should dramatically improve both our understanding of the physics of boiling and the predictive capabilities of models at various scale levels. However, for the multidimensional modeling framework to become an effective predictive tool, it must be complemented with accurate mechanistic closure laws of local boiling mechanisms. Boiling heat transfer has been studied quite extensively before. However, it turns out that the prevailing approach to the analysis of experimental data for both pool boiling and forced-convection boiling has been associated with formulating correlations which normally included several adjustable coefficients rather than based on first principle models of the underlying physical phenomena. One reason for this has been the tendency (driven by practical applications and industrial needs) to formulate single expressions which encompass a broad range of conditions and fluids. This, in turn, makes it difficult to identify various specific factors which can be independently modeled for different situations. The objective of this paper is to present a mechanistic modeling concept for both pool boiling and forced-convection boiling. The proposed approach is based on theoretical first-principle concepts, and uses a minimal number of coefficients which require calibration against experimental data. The proposed models have been validated against experimental data for water and parametrically tested. Model predictions are shown for a broad range of conditions.

Fabrication and characterization of optoelectronic device using CdSe nanocrystal quantum dots/single-walled carbon nanotubes (카드뮴 셀레나이드 양자점과 단일벽 탄소나노튜브로 구성된 이종 나노 소재를 기반으로 한 광전소자의 제작 및 특성평가)

  • Shim, Hyung-Cheoul;Jeong, So-Hee;Han, Chang-Soo;Kim, Soo-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.160-167
    • /
    • 2010
  • In this paper, we fabricated the optoelectronic device based on Cadmium selenide(CdSe) nanocrystal quantum dots (NQDs)/single-walled carbon nanotubes(SWNTs) heterostructure using dieletrophoretic force. The efficient charge transfer phenomena from CdSe to SWNT make CdSe-Pyridine(py)-SWNT unique heterostructures for novel optoelectronic device. The conductivity of CdSe-py-SWNT was increased when it was exposed at ultra violet(UV) lamp, and varied as a function of wavelength of incident light.

Investigation for the Fluid Motion in Closed End Capillaries (닫힌 모세관에서 유체 이송에 관한 연구)

  • Lim, Hosub;Lim, Seong Jin;Lee, Jinkee
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.23-29
    • /
    • 2014
  • Although many studies have been done on an open-end capillary, the invasion into a closed end capillary is still novel in its investigation. In this research we have explored the fluid invasion in closed-end capillaries where the shape of the meniscus and the height of invasion were accompanied by gas compression inside the capillary. Theoretically, the one dimensional momentum balance equation shows the fluid oscillation. In the experiments, we have found the different phenomena, either the fluid oscillation with low frequency or no oscillation. This discrepancy is mostly caused by two factors. First, a continuous decrease of the advancing contact angle due to decreasing invasion velocity as increasing pressure inside the closed-end capillary reduces the invasion velocities. Second, the high shear stress within the entrance length region was generated by the plug like velocity profile.

A Novel Large Area Negative Sputter Ion Beam source and Its Application

  • Kim, Steven
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.73-73
    • /
    • 1999
  • A large area negative metal ion beam source is developed. Kinetic ion beam of the incident metal ions yields a whole nucleation and growth phenomena compared to the conventional thin film deposition processes. At the initial deposition step one can engineer the surface and interface by tuning the energy of the incident metal ion beams. Smoothness and shallow implantation can be tailored according to the desired application process. Surface chemistry and nucleation process is also controlled by the energy of the direct metal ion beams. Each individual metal ion beams with specific energy undergoes super-thermodynamic reactions and nucleation. degree of formation of tetrahedral Sp3 carbon films and beta-carbon nitride directly depends on the energy of the ion beams. Grain size and formation of polycrystalline Si, at temperatures lower than 500deg. C is obtained and controlled by the energy of the incident Si-ion beams. The large area metal ion source combines the advantages of those magnetron sputter and SKIONs prior cesium activated metal ion source. The ion beam source produces uniform amorphous diamond films over 6 diameter. The films are now investigated for applications such as field emission display emitter materials, protective coatings for computer hard disk and head, and other protective optical coatings. The performance of the ion beam source and recent applications will be presented.

  • PDF

Wind-tunnel simulations of the suburban ABL and comparison with international standards

  • Kozmar, Hrvoje
    • Wind and Structures
    • /
    • v.14 no.1
    • /
    • pp.15-34
    • /
    • 2011
  • Three wind-tunnel simulations of the atmospheric boundary layer (ABL) flow in suburban country exposure were generated for length scale factors 1:400, 1:250 and 1:220 to investigate scale effects in wind-tunnel simulations of the suburban ABL, to address recommended wind characteristics for suburban exposures reported in international standards, and to test redesigned experimental hardware. Investigated parameters are mean velocity, turbulence intensity, turbulent Reynolds shear stress, integral length scale of turbulence and power spectral density of velocity fluctuations. Experimental results indicate it is possible to reproduce suburban natural winds in the wind tunnel at different length scales without significant influence of the simulation length scale on airflow characteristics. However, in the wind tunnel it was not possible to reproduce two characteristic phenomena observed in full-scale: dependence of integral length scales on reference wind velocity and a linear increase in integral length scales with height. Furthermore, in international standards there is a considerable scatter of recommended values for suburban wind characteristics. In particular, recommended integral length scales in ESDU 85020 (1985) are significantly larger than in other international standards. Truncated vortex generators applied in this study proved to be successful in part-depth suburban ABL wind-tunnel simulation that yield a novel methodology in studies on wind effects on structures and air pollution dispersion.

High Rank 7th Graders' Ideas on the Appropriate Inquiry Problems (중학교 1학년 상위권 학생들의 적절한 탐구 문제에 대한 생각)

  • Kim, Jae-Woo;Oh, Won-Kun
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.2
    • /
    • pp.261-266
    • /
    • 2002
  • To investigate the pupils' ideas about appropriate scientific inquiry problem, we have chosen the 105 boys and girls of 7th grade in a middle school in Seoul, Korea. Their marks in science are within the highest one-third of their classes. The pupils have made their own scientific inquiry questions, which is to be investigated by themselves in summer vacation. The 105 inquiry questions were gathered and evaluated by the pupils with 5-point Likert scale. From these, we have found that the questions inquiring novel phenomena, questioning causality, or containing scientific terms were evaluated as appropriate. Some questions were changed during performance. The pupils have changed their inquiry problems if they feel any difficulties in performing the inquiry.

Investigation on the Properties of a Microcellular Light-Weighted Humidity Controlling Tile (마이크로셀룰라 경량 조습타일의 특성 고찰)

  • Song, In-Hyuck;Lee, Eun-Jung;Kim, Hai-Doo;Kim, Young-Wook;Yun, Dal-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.404-411
    • /
    • 2011
  • The humidity controlling ceramic materials was developed by applying the phenomena of dew condensation in the capillary. It is said that the humidity range which human feels comfortable is from 40 to 70% in relative humidity. In this study, the ceramic tile using natural soils such as diatomite for interior wall was investigated. In particular, we had introduced novel processing routes for fabricating microcellular ceramics tile using hollow microsphere as a pore former. The microcellular pores in the humidity controlling ceramic materials showed the superior properties such as light-weight, heat insulation. The cell density was ${\sim}1.0{\times}10^9$ cells/$cm^3$ and density of sample was 0.65 g/$cm^3$ in the case of 1.71 wt% hollow microsphere content. Also, it is observed that the BET surface area and the pore volume of the sintered diatomite tile have the values of 40.92 $m^2$/g and 0.173 $cm^3$/g.

Virtual In-situ Sensor Calibration and the Application in Unitary Air Conditioners (유닛형 공기조화기 센서의 가상보정 방법 및 적용 특성 분석)

  • Yoon, Sungmin;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.65-72
    • /
    • 2018
  • Since data-driven building technologies have been widely applied to building energy systems, the accuracy of building sensors has more impacts on the building performance and system performance analysis. Various building sensors, however, can have typical errors including a random error (noise) and a systematic error (bias). The systematic error is indicated by the difference between the mean of measurements and their true value. It may occur due to the sensor's physical condition, measured phenomena, working environments inside the systems. Unfortunately, a conventional calibration method has limitations in calibrating the systematic errors because of the difference between working environments and calibration conditions. In such situations, a novel sensor calibration method is needed to handle various sensor errors, especially for systematic errors, in building energy systems having various thermodynamic environments. This study proposes a building sensor calibration method named Virtual In-situ Calibration (VIC) and shows how it is applied into a real building system and how it solves the sensor errors.

Numerical framework for stress cycle assessment of cables under vortex shedding excitations

  • Ruiz, Rafael O.;Loyola, Luis;Beltran, Juan F.
    • Wind and Structures
    • /
    • v.28 no.4
    • /
    • pp.225-238
    • /
    • 2019
  • In this paper a novel and efficient computational framework to estimate the stress range versus number of cycles curves experienced by a cable due to external excitations (e.g., seismic excitations, traffic and wind-induced vibrations, among others) is proposed. This study is limited to the wind-cable interaction governed by the Vortex Shedding mechanism which mainly rules cables vibrations at low amplitudes that may lead to their failure due to bending fatigue damage. The algorithm relies on a stochastic approach to account for the uncertainties in the cable properties, initial conditions, damping, and wind excitation which are the variables that govern the wind-induced vibration phenomena in cables. These uncertainties are propagated adopting Monte Carlo simulations and the concept of importance sampling, which is used to reduce significantly the computational costs when new scenarios with different probabilistic models for the uncertainties are evaluated. A high fidelity cable model is also proposed, capturing the effect of its internal wires distribution and helix angles on the cables stress. Simulation results on a 15 mm diameter high-strength steel strand reveal that not accounting for the initial conditions uncertainties or using a coarse wind speed discretization lead to an underestimation of the stress range experienced by the cable. In addition, parametric studies illustrate the computational efficiency of the algorithm at estimating new scenarios with new probabilistic models, running 3000 times faster than the base case.

Synthesis, interfacial properties, and antimicrobial activity of a new cationic gemini surfactant

  • Maneedaeng, Atthaphon;Phoemboon, Sakonwan;Chanthasena, Panjamaphon;Chudapongse, Nuannoi
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2313-2320
    • /
    • 2018
  • Tetramethylene-1,4-bis(N,N-dodecylammonium bromide), cationic gemini surfactant, (12-4-12) was first synthesized with an one-step and shortened procedure and its interfacial and antimicrobial properties were compared with a conventional single-chain cationic surfactant, cetyltrimethylammonium bromide (CTAB). The interfacial and thermodynamic properties of both surfactants reveal that critical micelle concentration (CMC) of this novel synthetic cationic dimeric surfactant is lower than that of cationic monomeric surfactant at almost 15 times of its magnitude, which is due to the increase in hydrophobicity of the surfactant molecules by having dual hydrocarbon chains. In comparison with CTAB, the produced compound 12-4-12 yields much better interfacial and thermodynamic properties. The antimicrobial activities of the synthesized gemini surfactant were tested against eight strains of bacteria, as well as two strains of fungi. The results showed that both 12-4-12 compound and CTAB exhibited higher inhibitory effects on the growth of Gram-positive bacteria and fungi than that of Gram-negative bacteria. The minimum inhibitory concentrations in molar of 12-4-12 against all tested Gram-negative bacteria were lower than those of CTAB, which is hypothetically due to the lower HLB together with smaller CMC values of our gemini surfactant.