• 제목/요약/키워드: Novel metal

검색결과 641건 처리시간 0.023초

Analysis of a Triangular-shaped Plasmonic Metal-Insulator-Metal Bragg Grating Waveguide

  • Jafarian, Behnaz;Nozhat, Najmeh;Granpayeh, Nosrat
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.118-123
    • /
    • 2011
  • A novel triangular-shaped plasmonic metal-insulator-metal (MIM) Bragg grating waveguide is introduced, whose band-gap is narrower than that of the conventional step type and wider than that of the sawtoothshaped one. Moreover apodized triangular-shaped MIM Bragg grating structures are proposed in order to reduce the side lobes of the transmission spectrum, because the Bragg reflector with a sawtooth profile has a smoother transmission spectrum than that of a triangular-shaped one. The performance of the proposed structures is simulated by using the finite difference time domain method.

Analysis of Laser Control Effects for Direct Metal Deposition Process

  • Choi Joo-Hyun;Chang Yoon-Sang
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1680-1690
    • /
    • 2006
  • As a promising and novel manufacturing technology, laser aided direct metal deposition (DMD) process produces near-net-shape functional metal parts directly from 3-D CAD models by repeating laser cladding layer by layer. The key of the build-up mechanism is the effective control of powder delivery and laser power to be irradiated into the melt-pool. A feedback control system using two sets of optical height sensors is designed for monitoring the melt-pool and real-time control of deposition dimension. With the feedback height control system, the dimensions of part can be controlled within designed tolerance maintaining real time control of each layer thickness. Clad nugget shapes reveal that the feedback control can affect the nugget size and morphology of microstructure. The pore/void level can be controlled by utilizing pulsed-mode laser and proper design of deposition tool-path. With the present configuration of the control system, it is believed that more innovation of the DMD process is possible to the deposition of layers in 3-D slice.

X-ray Structure and Electrochemical Properties of Ferrocene-Substituted Metalloporphyrins

  • 김진원;이석우;나용환;이기평;도영규;정세채
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권12호
    • /
    • pp.1316-1322
    • /
    • 2001
  • Transition metal complexes of novel mono- and di-ferrocene-substituted porphyrins have been synthesized and characterized by structural and electrochemical methods. The X-ray structures of Mn(FPTTP)Cl and Mn(DFTTP)Cl showed the distorted square pyramidal coordination geometry with syn configuration of chloride and ferrocenyl substituents. The electrochemistry of ferrocene-substituted porphyrins and their metal complexes has been determined to elucidate the ${\pi}-conjugation$ effect of the porphyrin ring. The ferrocenyl group of H2FPTTP underwent a reversible one-electron transfer process at 0.30 V, indicating the good electron donating effect of the phorphyrin ring to the ferrocene substituent. The redox potential of the ferrocenyl subunit and porphyrin ring was affected by the central metal ions of the metalloporphyrins, that is, Zn(II) and Ni(II) made the oxidation of ferrocene much easier and Mn(III) made it harder. The ferrocene subunits of H2DFTTP interacted electrochemically with each other with peak splitting of 0.21 V. The strength of the electrochemical interactions between the two ferrocenyl substituents can be controlled by central metal ions of metalloporphyrins.

Flexible multimode pressure sensor based on liquid metal

  • Zhou, Xiaoping;Yu, Zihao
    • Smart Structures and Systems
    • /
    • 제28권6호
    • /
    • pp.839-853
    • /
    • 2021
  • In this paper, a novel multimode liquid metal-based pressure sensor is developed. The main body of the sensor is composed of polydimethylsiloxane (PDMS) elastomer. The structure of the sensor looks like a sandwich, in which the upper structure contains a cylindrical cavity, and the bottom structure contains a spiral microchannel, and the middle partition layer separates the upper and the bottom structures. Then, the liquid metal is injected into the top cavity and the bottom microchannel. Based on linear elastic fracture mechanics, the deformation of the microchannel cross-section is theoretically analyzed. The changes of resistance, capacitance, and inductance of the microchannel under pressure are deduced, and the corresponding theoretical models are established. The theoretical values of the pressure sensor are in good agreement with experimental data, implying that the developed theoretical model can explain the performance of the sensor well.

Biochemical and Biodiversity Insights into Heavy Metal Ion-Responsive Transcription Regulators for Synthetic Biological Heavy Metal Sensors

  • Jung, Jaejoon;Lee, Sang Jun
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권10호
    • /
    • pp.1522-1542
    • /
    • 2019
  • To adapt to environmental changes and to maintain cellular homeostasis, microorganisms adjust the intracellular concentrations of biochemical compounds, including metal ions; these are essential for the catalytic function of many enzymes in cells, but excessive amounts of essential metals and heavy metals cause cellular damage. Metal-responsive transcriptional regulators play pivotal roles in metal uptake, pumping out, sequestration, and oxidation or reduction to a less toxic status via regulating the expression of the detoxification-related genes. The sensory and regulatory functions of the metalloregulators have made them as attractive biological parts for synthetic biology, and the exceptional sensitivity and selectivity of metalloregulators toward metal ions have been used in heavy metal biosensors to cope with prevalent heavy metal contamination. Due to their importance, substantial efforts have been made to characterize heavy metal-responsive transcriptional regulators and to develop heavy metal-sensing biosensors. In this review, we summarize the biochemical data for the two major metalloregulator families, SmtB/ArsR and MerR, to describe their metal-binding sites, specific chelating chemistry, and conformational changes. Based on our understanding of the regulatory mechanisms, previously developed metal biosensors are examined to point out their limitations, such as high background noise and a lack of well-characterized biological parts. We discuss several strategies to improve the functionality of the metal biosensors, such as reducing the background noise and amplifying the output signal. From the perspective of making heavy metal biosensors, we suggest that the characterization of novel metalloregulators and the fabrication of exquisitely designed genetic circuits will be required.

새로운 티타늅 실리사이드 형성공정과 STI를 이용한 서브 0,1$\mu\textrm{m}$ ULSI급 소자의 특성연구 (A Study on sub 0.1$\mu\textrm{m}$ ULSI Device Quality Using Novel Titanium Silicide Formation Process & STI)

  • 엄금용;오환술
    • 대한전자공학회논문지SD
    • /
    • 제39권5호
    • /
    • pp.1-7
    • /
    • 2002
  • Deep sub-micron bulk CMOS circuits require gate electrode materials such as metal silicide and titanium silicide for gate oxides. Many authors have conducted research to improve the quality of the sub-micron gate oxide. However, few have reported on the electrical quality and reliability of an ultra-thin gate. In this paper, we will recommend a novel shallow trench isolation structure and a two-step TiS $i_2$ formation process to improve the corner metal oxide semiconductor field-effect transistor (MOSFET) for sub-0.1${\mu}{\textrm}{m}$ VLSI devices. Differently from using normal LOCOS technology, deep sub-micron CMOS devices using the novel shallow trench isolation (STI) technology have unique "inverse narrow-channel effects" when the channel width of the device is scaled down. The titanium silicide process has problems because fluorine contamination caused by the gate sidewall etching inhibits the silicide reaction and accelerates agglomeration. To resolve these Problems, we developed a novel two-step deposited silicide process. The key point of this process is the deposition and subsequent removal of titanium before the titanium silicide process. It was found by using focused ion beam transmission electron microscopy that the STI structure improved the narrow channel effect and reduced the junction leakage current and threshold voltage at the edge of the channel. In terms of transistor characteristics, we also obtained a low gate voltage variation and a low trap density, saturation current, some more to be large transconductance at the channel for sub-0.1${\mu}{\textrm}{m}$ VLSI devices.

Leakage Current Mechanism of Thin-Film Diode for Active-Matrix Liquid Crystal Displays

  • Lee, Myung-Jae;Chung, Kwan-Soo;Kim, Dong-Sik
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.126-132
    • /
    • 2002
  • The origin of image-sticking in metal-insulator-metal type thin-film diode liquid crystal displays(TFD-LCDs) is the asymmetric current-voltage(I-V) characteristic of TFD element. We developed that TFD-LCDs have reduced-image-sticking. Tantalum pentoxide(Ta$_2$O$\sub$5/) is a candidate for use in metal-insulator-metal(MIM) capacitors in switching devices for active-matrix liquid crystal displays(AM-LCDs). High quality Ta$_2$O$\sub$5/ thin films have been obtained from anodizing method. We fabricated a TFD element using Ta$_2$O$\sub$5/ films which had perfect current-voltage symmetry characteristics. We applied novel process technologies which were postannealed whole TFD element instead of conventional annealing to the fabrication. One-Time Post-Annealing(OPTA) heat treatment process was introduced to reduce the asymmetry and shift of the I-V characteristics, respectively. OPTA means that the whole layers of lower metal, insulator, and upper metal are annealed at one time. Futhermore, in this paper, we discussed the effects of top-electrode metals and annealing conditions.

  • PDF

풍력발전기 블레이드 변형 측정을 위한 액체금속 스트레인 게이지 개발 (Development of Liquid Metal Strain Gauge for Measuring WT Blade's Deformation)

  • 박인겸;서영호;김병희
    • 한국정밀공학회지
    • /
    • 제32권3호
    • /
    • pp.307-314
    • /
    • 2015
  • In this paper, the embedding type novel liquid metal strain gauge was developed for measuring the deformation of wind turbine blades. In general, the conventional methods for the SHM have many disadvantages such as frequency distortion in FBG sensors, the low gauge factor and mechanical failures in strain gauges and extremely sophisticated filtering in AE sensors. However, the liquid metal filled in a pre-confined micro channel shows dramatic characteristics such as high sensitivity, flexibility and robustnes! s to environment. To adopt such a high feasibility of the liquid metal in flexible sensor applications, the EGaIn was introduced to make flexible liquid metal strain gauges for the SHM. A micro channeled flexible film fabricated by the several MEMS processes and the PDMS replication was filled with EGaIn and wire-connected. Lots of experiments were conducted to investigate the performance of the developed strain gauges and verify the feasibility to the actual wind turbine blades health monitoring.

압축기용 구동스크롤의 밀폐형 배압 금형 개발 (Development of a Closed-die Design with Backpressure to Forge Rotating Scrolls)

  • 김용배;정기호;이상목;김응주;이종섭;최두순;이근안
    • 소성∙가공
    • /
    • 제22권4호
    • /
    • pp.183-188
    • /
    • 2013
  • Scroll compressors are widely used in air conditioning systems and in automobiles due to their low pressure loss, minimal vibrations, and light-weight. Open-die forging with back pressure is used to forge the rotating scroll, and it requires special care since the forging die can be severely damaged at the fixed end of the spiral cavity similar to a fracture of a cantilever beam. To overcome the inevitable weakness of the forging die due to such damage, an innovative design is necessary. In this study, structural analysis using the finite element method was conducted to determine the reason for the fracture of the forging die. A novel design to avoid stress concentrations and vertical deflection, causing serious damage to the die, is suggested.

내환경성 금속인식 정보단말기에 관한 연구 (Data Terminal for Metal Detection Application in Hazardous Environment)

  • 최규남
    • 한국정보통신학회논문지
    • /
    • 제15권5호
    • /
    • pp.1183-1188
    • /
    • 2011
  • 고온다습하며 이물질이 존재하는 일반적인 금속감지 기술이 적용되기 어려운 환경에서도 사용할 수 있는 금속위치감지 방법을 제안한다. 섭씨 300도가 넘는 환경에서는 마이크로웨이브, 초음파, 광파를 매체로 하는 일반적인 송수신용 전자소자를 사용하는 금속감지 센서는 전자소자의 동작온도 범위를 넘어서므로 적용하는데 어려움이 있었다. 본 연구에서는 금속감지를 위하여 노출되는 면에는 수동소자를 사용하고 전자파를 금속 위치감지에 이용하는 기법을 사용한 금속의 위치감지 장치에서 전자파의 주파수, 감지거리가 금속감지 센서의 감도에 미치는 영향을 측정하였다. 측정된 결과는 500mm 간격에서도 1mm 해상도를 갖고 위치를 감지할 수 있으며 고온에서도 금속의 위치 측정이 가능함을 보여주었다.