• Title/Summary/Keyword: Normalized parameter

Search Result 268, Processing Time 0.024 seconds

Multi-Parameter Based Scheduling for Multi-user MIMO Systems

  • Chanthirasekaran, K.;Bhagyaveni, M.A.;Parvathy, L. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2406-2412
    • /
    • 2015
  • Multi-user multi-input multi-output (MU-MIMO) system has attracted the 4th generation wireless network as one of core technique for performance enrichment. In this system rate control is a challenging problem and another problem is optimization. Proper scheduling can resolve these problems by deciding which set of user and at which rate the users send their data. This paper proposes a new multi-parameter based scheduling (MPS) for downlink multi-user multiple-input multiple-output (MU-MIMO) system under space-time block coding (STBC) transmissions. Goal of this MPS scheme is to offer improved link level performance in terms of a low average bit error rate (BER), high packet delivery ratio (PDR) with improved resource utilization and service fairness among the user. This scheme allows the set of users to send data based on their channel quality and their demand rates. Simulation compares the MPS performance with other scheduling scheme such as fair scheduling (FS), normalized priority scheduling (NPS) and threshold based fair scheduling (TFS). The results obtained prove that MPS has significant improvement in average BER performance with improved resource utilization and fairness as compared to the other scheduling scheme.

Performance Analysis of The CCITT X.25 Protocol (X. 25 Protocol의 성능 분석)

  • 최준균;은종관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.1
    • /
    • pp.25-39
    • /
    • 1986
  • In this paper, we analyze the performance, particularly the flow control mechanism, of the CCITT X.25 protocol in a packet-switched network. In this analysis, we consider the link and packet layers separately, and investigate the performance in three measures; normalized channel throughput, mean transmission time, and transmission efficiency. Each of these measures is formulated in terms of given protocol parameters such as windos size, $T_1$ and $T_2$ values, message length, and so forth. We model the service procedure of the inpur traffic based on the flow control mechanism of the X.25 protocol, and investigate the mechanism of the sliding window flow control with the piggybacked acknowlodgment scheme using a discrete-time Markov chain model. With this model, we study the effect of variation of the protoccol parameters on the performance of the X.25 protocol. From the numerical results of this analysis one can select the optimal valuse of the protocol parameters for different channel environments. it has been found that to maintain the trasnmission capacity satisfactorily, the window size must be greater than or equal to 7 in a high-speed channel. The time-out value, $T_1$, must carefully be selected in a noisy channel. In a normal condition, it should be in the order of ls. The value of $T_2$ has some effect on the transmission efficiency, but is not critical.

  • PDF

A Statistical Analysis to the VLF Tanδ Criteria for Aging Diagnosis in Power Cables (전력케이블 열화진단을 위한 극저주파 탄델타 판정기준의 통계적 해석)

  • Jung, Woosung;Kim, Seongmin;Lim, Jangseob;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.1-5
    • /
    • 2020
  • In this study, the objective is to improve the criteria used for statistical comparison of the VLF tanδ (TD) database and failure rate according to water-tree degradation in underground distribution power cables. The aging condition of the KEPCO criteria is divided into 6 levels using the Weibull distribution, and the "failure imminent" condition is quantified by using the statistical end-point of the lifetime parameter of the VLF big-data group obtained from KEPCO. Moreover, new criteria with a 2-dimensional combination of TD, DTD, and a statistical normalized factor are suggested. These criteria exhibit high reproducibility for the detection of cables in an imminent failure state. Consequently, it is expected that the adoption of the extended VLF-2019 criteria will reduce the asset management cost of cable replacement compared to the VLF-2012 criteria of KEPCO.

Extensible Elastica Solutions on the Large Deflection of Fiber Cantilever with Circular Wavy Crimp (I) - Derivation of Models and Their Solutions-

  • Jung Jae Ho;Kang Tae Jin
    • Fibers and Polymers
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 2005
  • Extensible elastica solutions of two-dimensional deflection of crimped fiber cantilever of circular wavy crimp were obtained for one end clamped boundary under concentrated, inclined and dead tip load Fiber was also regarded as a linear elastic material. Crimp was described as a combination of semicircular arcs smoothly connected with each other having con­stant curvature of all the same magnitude and alternative sign. Also the inclined load direction was taken into account. The solutions were expressed as the recursive forms of integrals in two different cases, which can also be transformed to elliptic integrals respectively. Comparing the data with inextensible ones was carried out. Consequently in the solution, the normal strain of neutral axis is expressed in terms of cross-sectional area, second moment of area and normalized load parameter. Examples of the circular cross-sectioned fiber are presented. As a result, the differences of normalized load between inexten­sible and extensible elastica solutions when the radius ratio becomes 0.1 were maximum $\Lambda$ = 0.1.

Adaptive echo canceller combined with speech coder for mobile communication systems (이동통신 시스템을 위한 음성 부호화기와 결합된 적응 반향제거기에 관한 연구)

  • 이인성;박영남
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1650-1658
    • /
    • 1998
  • This paper describes how to remove echoes effectively using speech parameter information provided form speech coder. More specially, the proposed adaptive echo canceller utilizes the excitation signal or linearly predicted error signal instead of output speech signal of vocoder as the input signal for adaptation algorithm. The normalized least mean ssquare(NLMS) algorithm is used for the adaptive echo canceller. The proposed algorithm showed a fast convergece charactersitcis in the sinulatio compared to the conventional method. Specially, the proposed echo canceller utilizing the excitation signal of speech coder showed about four times fast convergence speed over the echo canceller utilizing the output speech signal of the speech coder for the adaptation input.

  • PDF

Fault Detection and Diagnosis Simulation for CAV AHU System (정풍량 공조시스템의 고장검출 및 진단 시뮬레이션)

  • Han, Dong-Won;Chang, Young-Soo;Kim, Seo-Young;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.687-696
    • /
    • 2010
  • In this study, FDD algorithm was developed using the normalized distance method and general pattern classifier method that can be applied to constant air volume air handling unit(CAV AHU) system. The simulation model using TRNSYS and EES was developed in order to obtain characteristic data of CAV AHU system under the normal and the faulty operation. Sensitivity analysis of fault detection was carried out with respect to fault progress. When differential pressure of mixed air filter increased by more than about 105 pascal, FDD algorithm was able to detect the fault. The return air temperature is very important measurement parameter controlling cooling capacity. Therefore, it is important to detect measurement error of the return air temperature. Measurement error of the return air temperature sensor can be detected at below $1.2^{\circ}C$ by FDD algorithm. FDD algorithm developed in this study was found to indicate each failure modes accurately.

Performance Improvement of an Extended Kalman Filter Using Simplified Indirect Inference Method Fuzzy Logic (간편 간접추론 방식의 퍼지논리에 의한 확장 칼만필터의 성능 향상)

  • Chai, Chang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.131-138
    • /
    • 2016
  • In order to improve the performance of an extended Kalman filter, a simplified indirect inference method (SIIM) fuzzy logic system (FLS) is proposed. The proposed FLS is composed of two fuzzy input variables, four fuzzy rules and one fuzzy output. Two normalized fuzzy input variables are the variance between the trace of a prior and a posterior covariance matrix, and the residual error of a Kalman algorithm. One fuzzy output variable is the weighting factor to adjust for the Kalman gain. There is no need to decide the number and the membership function of input variables, because we employ the normalized monotone increasing/decreasing function. The single parameter to be determined is the magnitude of a universe of discourse in the output variable. The structure of the proposed FLS is simple and easy to apply to various nonlinear state estimation problems. The simulation results show that the proposed FLS has strong adaptability to estimate the states of the incoming/outgoing moving objects, and outperforms the conventional extended Kalman filter algorithm by providing solutions that are more accurate.

Evaluation of Creep Crack Growth Failure Probability at Weld Interface Using Monte Carlo Simulation (몬테카를로 모사에 의한 용접 계면에서의 크리프 균열성장 파손 확률 평가)

  • Lee Jin-Sang;Yoon Kee-Bong
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2005
  • A probabilistic approach for evaluating failure risk is suggested in this paper. Probabilistic fracture analyses were performed for a pressurized pipe of a Cr-Mo steel reflecting variation of material properties at high temperature. A crack was assumed to be located along the weld fusion line. Probability density functions of major variables were determined by statistical analyses of material creep and creep crack growth data measured by the previous experimental studies by authors. Distributions of these variables were implemented in Monte Carlo simulation of this study. As a fracture parameter for characterizing growth of a fusion line crack between two materials with different creep properties, $C_t$ normalized with $C^*$ was employed. And the elapsed time was also normalized with tT, Resultingly, failure probability as a function of operating time was evaluated fur various cases. Conventional deterministic life assessment result was turned out to be conservative compared with that of probabilistic result. Sensitivity analysis for each input variable was conducted to understand the most influencing variable to the analysis results. Internal pressure, creep crack growth coefficient and creep coefficient were more sensitive to failure probability than other variables.

Nonlinear vibration analysis of carbon nanotube reinforced composite plane structures

  • Rezaiee-Pajand, Mohammad;Masoodi, Amir R.;Rajabzadeh-Safaei, Niloofar
    • Steel and Composite Structures
    • /
    • v.30 no.6
    • /
    • pp.493-516
    • /
    • 2019
  • This paper is dedicated to nonlinear static and free vibration analysis of Uniform Distributed Carbon Nanotube Reinforced Composite (UD-CNTRC) structures under in-plane loading. The authors have suggested an efficient six-node triangular element. Mixed Interpolation of Tensorial Components (MITC) approach is employed to alleviate the membrane locking phenomena. Moreover, the behavior of the well-known LST element is considerably improved by applying an additional linear interpolation on the strain fields. Based on the rule of mixture, the properties of CNTRC are obtained. In this study, only the uniform distributed CNTs are employed through the thickness direction of element. To achieve the natural frequencies and shape modes, the eigenvalue problem is also solved. Using Total Lagrangian Principles, large amplitude free vibration is considered based on the first normalized mode shape of structure. Different well-known plane problem benchmarks and some proposed ones are studied to validate the accuracy and capability of authors' formulations. In addition, the effects of length to the height ratio of beam, CNT's characteristics, support conditions and normalized amplitude parameter on the linear and nonlinear vibration parameters are investigated.

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.