• Title/Summary/Keyword: Normal wave condition

Search Result 61, Processing Time 0.033 seconds

Resistive Grounding Technique of Heat Sink for Reducing Radiation Noise

  • Ahn, Chang-Hoi;Oh, JaeHyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1724-1728
    • /
    • 2014
  • Heat sink has been used to help an electrical device operate in normal temperature condition. But heat sink radiates unwanted electromagnetic wave, which may cause electromagnetic interference problem. A resistance loaded grounding technique is proposed to reduce electromagnetic wave radiation by a heat sink. Numerical simulations are accomplished to find optimal loading resistance. Also electromagnetic fields radiated by from a heat sink are measured and compared with the simulation results. The test results verify the usefulness of the proposed technique.

Rat Skin Permeation Characteristics of L-cystein to Common Permanent Wave Drug In Vitro (상용 퍼머넌트 웨이브 약제인 L-cystein의 랫드 피부 투과 특성)

  • 김용렬;윤철훈;김낙주
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2001
  • Hair will be persuit of beautifulness of human being in various permanent wave by many kinds of its drugs. Skin is based upon the hair which enroll the body of high living animals and have multiple membrane structure In this study used rat the effects of commercial permanent wave products to skin which are composed with L- cysteine and bases Results are as follow: the content of penetration 4 hors later with steady state and no significant changeable after 20 hours later. In cysteine groups, lag time and permeability coefficient of healthy skin is 2.22hr and 0.13$\mu\textrm{g}$/㎥ hr, lag time and permeability coefficient of old skin is 4.01 hr and 0.108 $\mu\textrm{g}$/㎥ hr . In conclusion of study lag time and permeability coefficient in old skin and wounded skin are faster than healthy skin. We notified that fine rinkle and rash of skin were changeable in the case of treating with permanent wave drugs than normal skin.

  • PDF

The analysis of the resonance characteristics of a traveling wave type ultrasonic motor by applying the normal force and driving voltage (진행파 회전형 초음파 모터의 가압력과 구동전압에 따른 공진특성의 변화 분석)

  • Oh, Jin-Heon;Park, Cheol-Hyeon;Lim, Kee-Joe;Kim, Hyeon-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.324-324
    • /
    • 2008
  • Piezoelectric ceramics is an active element that makes stator to vibrate to generate rotational force in ultrasonic motors. In drive of ultrasonic motors, many factors that affect to the resonance characteristics of piezoelectric ceramics exist. For example, those factors are bonding condition with elastic body, the magnitude of electric field, the normal force for frictional drive and the emission of heat due to vibration and friction and so on. Therefore, it is important to research the inclination of property variation of piezoelectric ceramics in circumstance that has complex elements. In this paper, we focused and analyzed the resonance characteristics of ultrasonic motor due to the magnitude of the driving voltage and normal force.

  • PDF

Efficient electromagnetic boundary conditions to accelerate optimization of RF devices

  • Cho, Yong-Heui
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.50-55
    • /
    • 2011
  • To achieve efficient field formulations and fast numerical computations, the reciprocal relations and equivalence between tangential and normal boundary conditions for electromagnetic fields are discussed in terms of the Maxwell's differential equations. Using the equivalence of each boundary condition, we propose the six essential boundary conditions, which may be applicable to matching electromagnetic discontinuities to efficiently design RF devices. In order to verify our approach, the reflection characteristics of a rectangular waveguide step are compared with respect to six essential boundary conditions.

A Study on the temperature compensation of MU-60 Ultrasonic Motor by frequency control (주파수 제어에 의한 MU-60 초음파모터의 온도보상에 관한 연구)

  • 서기열;신일철;임중열;최장균;차인수
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.441-444
    • /
    • 1997
  • This paper describes the bending traveling-wave type ultrasonic motor which generates the traveling wave by combining two standing waves with phase difference time and space. In +2$0^{\circ}C$~3$0^{\circ}C$, the operation characteristic of USM has represented normal condition. But in the other temperature, the operation characteristic of USM has abnormal condition, that is driving frequency, drive current and r.p.m are down. The recent USM has controller without temperature compensation. This study aimed at fuzzy controller which must follow the frequency at operation temperature and then r.p.m and torque increased.

  • PDF

Efficient QRS Detection and PVC(Premature Ventricular Contraction) Classification based on Profiling Method (효율적인 QRS 검출과 프로파일링 기법을 통한 심실조기수축(PVC) 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.705-711
    • /
    • 2013
  • QRS detection of ECG is the most popular and easy way to detect cardiac-disease. But it is difficult to analyze the ECG signal because of various noise types. Also in the healthcare system that must continuously monitor people's situation, it is necessary to process ECG signal in realtime. In other words, the design of algorithm that exactly detects QRS wave using minimal computation and classifies PVC by analyzing the persons's physical condition and/or environment is needed. Thus, efficient QRS detection and PVC classification based on profiling method is presented in this paper. For this purpose, we detected QRS through the preprocessing method using morphological filter, adaptive threshold, and window. Also, we applied profiling method to classify each patient's normal cardiac behavior through hash function. The performance of R wave detection, normal beat and PVC classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.77% in R wave detection and the rate of 0.65% in normal beat classification error and 93.29% in PVC classification.

Analysis of the Electromagnetic Scattering by Conducting Strip Gratings with 2 Dielectric Layers (접지평면위에 2개의 유전체층을 가지는 도체띠 격자구조에서의 전자파산란 해석)

  • 김용연;방성일
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.1
    • /
    • pp.102-109
    • /
    • 1999
  • In this paper, Electromagnetic scattering problem by a perfectly conducting strip grating with 2 dielectric layer on a grounded plane by incidence of a electric wave is analyzed by applying the PMM (Point Matching Method) known as a simple procedure. The scattered electromagnetic fields are expanded in a series of Floquet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the conducting boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip When the incident angle is normal incidence the minimum value of the geometrically normalized reflected power according as relative permittivity is increased it should be noted that the value of the strip width gets moved toward high value. Them most energy by a normal incident wave is scattered in direction of the other angles except normal incident angle.

  • PDF

Effects of Skin Permeation for Rat of Thioglycolic Acid (티오글리콜산의 랫드 피부에 대한 투과 영향)

  • 정덕채;오세영;황성규
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.65-70
    • /
    • 2004
  • Hair is based upon the skin which enroll the body of high living animals and have multiple membrane structure. This study were used rats and carried out to find out the effects of commercial permanent wave products to skin which are composed of thioglycolic acid and bases. Results were as follows. Permanent wave penetrated to 3 hours later with steady state in skins and was not significant changeable after 20hr later. In case of neutralizer with thioglycolic acid lag time and permeability coefficient in healthy skin were 3.38hr and 0.96$\mu\textrm{g}$/$\textrm{cm}^2$/hr, in old skin were 3.14hr and 0.l28$\mu\textrm{g}$/$\textrm{cm}^2$/hr, and in wounded skin were 3.08hr and 0.157$\mu\textrm{g}$/$\textrm{cm}^2$/hr. In conclusion, lag time and permeability coefficient in old skin and wounded skin were faster than healthy skin. In vivo which was studied by general time and method of permanent wave. We found out that fine rinkle and rash of skin were changeable in the case of treating with permanent wave drugs than normal skin. Also, permanent wave drugs could induced rash and eruption at the skin by the naked eye.

Experimental Study for Wave Reflection of Partially Perforated Caisson by Slit Shape of Front Wall (부분 유공케이슨의 Slit 형상에 따른 반사특성 실험)

  • Lee, Jong-In
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1455-1462
    • /
    • 2013
  • This study examines the reflection of a partially perforated wall with single chamber by 2D and 3D hydraulic experiments. The effects of slit shape on the front wall, relative chamber width and wave steepness were discussed. For the normal incident wave condition, the reflections of horizontal slit case were lower than that of the vertical slit with the similar porosity, but the differences are not significant. When the wave steepness is relatively small, the reflection coefficients are large. In the oblique incidence, the normalized wave heights along a perforated wall with similar porosity are almost same for the vertical and horizontal slit walls and therefore the difference by slit shape can be ignored.

A Basic Research on Estimation of Material Condition by Using Nonlinear Elastic Modulus (비선형 탄성계수를 이용한 재료변질 상태평가에대한 기초적 연구)

  • 김경조;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.348-352
    • /
    • 1995
  • In the conventional linear elasticity, ultrasonic velocity is determined by elastic modulus and density of te medium which ultrasonic wave propagates through. But, practical ultrsonic wave depends on the stress acting in the medium, and as the stress increases such dependency becomes nonlinear. This nonlinear dependencyof ultrasonic velocity on stress can be identified by using nonlinear elastic modulus up to 4th order. In thid paper, with the above background relationships between nonlinear elastic modulus and the internalstatus of materials, normal, plastic deformed or heat stressed, are discussed. For this purpose, a new type of measuring system extended from the general nondestructive UT(ultrasonic test) equipment is constructed.

  • PDF