• Title/Summary/Keyword: Normal section curve

Search Result 31, Processing Time 0.026 seconds

Strain-Based Shear Strength Model for Prestressed Beams (프리스트레스트 콘크리트 보를 위한 변형률 기반 전단강도 모델)

  • Kang, Soon-Pil;Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.75-84
    • /
    • 2009
  • An analytical model for predicting the shear strength of prestressed concrete beams without shear reinforcement was developed, on the basis of the existing strain-based shear strength model. It was assumed that the compression zone of intact concrete in the cross-section primarily resisted the shear forces rather than the tension zone. The shear capacity of concrete was defined based on the material failure criteria of concrete. The shear capacity of the compression zone was evaluated along the inclined failure surface, considering the interaction with the compressive normal stress. Since the distribution of the normal stress varies with the flexural deformation of the beam, the shear capacity was defined as a function of the flexural deformation. The shear strength of a beam was determined at the intersection of the shear capacity curve and the shear demand curve. The result of the comparisons to existing test results showed that the proposed model accurately predicted the shear strength of the test specimens.

Fire resistance assessment of high strength segment concrete depending on PET fiber amount under fire curves (화재곡선과 PET섬유 혼입량에 따른 고강도 세그먼트 콘크리트의 화재저항성 평가에 대한 연구)

  • Choi, Soon-Wook;Lee, Gyu-Phil;Chang, Soo-Ho;Park, Young-Taek;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.311-320
    • /
    • 2014
  • High strength concrete is not only vulnerable to the occurrence of spalling which generates the loss of cross-section in concrete structures but produces faster degradation in its mechanical properties than normal strength concrete in the event of fire. This study aims to evaluate fire resistance of high strength segment concrete with PET fibers mixed to prevent spalling under ISO834 (2hr) and RABT fire curve. As results, the samples without PET fibers show the concrete loss up to the depth of about 8 cm and 9.5 cm from the surface exposed to fire under ISO834 and RABT fire curve respectively. The samples mixed with PET fiber of 0.1% show no spalling under ISO834 fire curve and the spalled thickness of 6.5 cm under RABT fire curve after the fire tests. Finally, the sample mixed with PET fiber of 0.2% shows no spalling under RABT fire curve. The results indicate that the suitable amounts of PET fiber for securing fire resistance performance of this high strength segment concrete are 0.1% under ISO834 fire curve and 0.2% under RABT fire curve. However, even though spalling does not occur, it is necessary to repair the deterioration of concrete up to 4 cm from the surface exposed to fire after fire.

A Study on the Construction of CAD/CAM system ; for Machining of Sculptured Surface of Die (금형의 자유곡면 가공용 CAD/CAM SYSTEM 구축에 관한 연구)

  • Koo, Young-Hae;Lee, Dong-Ju;Namgung, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.96-105
    • /
    • 1992
  • A study on the construction of a CAD/CAM system operated by 16 Bit PC basic language, for machining sculptured surface of die, was carried out. The system consists of 2 steps i.e., process for geometric modelling by wire frame and process for machining data generation. Geometric modelling for sculptured surface is made by the point data fitting, parallel sweeping, normal sweeping and linear connection of cross section curve. Machining data are gained by cutter off-set of geometric model data and machining carried out by DNC. This system is to be proved enough for rough cutting by actual machining experiment. But, for becoming a high level system, another method of cutter off-set has to be regarded and system must be reconstructed by another program language.

  • PDF

The Sectional Analysis of Trunk-lid using the Equilibrium Approach and Three-Dimensional Shape Composition (평형해법을 이용한 트렁크 리드의 단면해석과 3차원 형상합성)

  • 정동원
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.66-71
    • /
    • 2001
  • A sectional analysis of trunk-lid carried out by using the equilibrium approach based on the force balance together with geometric relations and plasticity theory. In computing a force balance equation, it is required to define a geometric curve approximating the shape of sheet metal at any step of deformation from the interaction between the die and the deformed sheet. The trunk-lid panel material is assumed to possess normal anisotropy and to obey Hill's new yield criterion. Deformation of each section of trunk-lid panel is simulated and composed to get the three-dimensional shape by using CAD technique. It was shown that the three-dimensional shape composition of the two-dimensional analysis.

  • PDF

Application of Quality Statistical Techniques Based on the Review and the Interpretation of Medical Decision Metrics (의학적 의사결정 지표의 고찰 및 해석에 기초한 품질통계기법의 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.243-253
    • /
    • 2013
  • This research paper introduces the application and implementation of medical decision metrics that classifies medical decision-making into four different metrics using statistical diagnostic tools, such as confusion matrix, normal distribution, Bayesian prediction and Receiver Operating Curve(ROC). In this study, the metrics are developed based on cross-section study, cohort study and case-control study done by systematic literature review and reformulated the structure of type I error, type II error, confidence level and power of detection. The study proposed implementation strategies for 10 quality improvement activities via 14 medical decision metrics which consider specificity and sensitivity in terms of ${\alpha}$ and ${\beta}$. Examples of ROC implication are depicted in this paper with a useful guidelines to implement a continuous quality improvement, not only in a variable acceptance sampling in Quality Control(QC) but also in a supplier grading score chart in Supplier Chain Management(SCM) quality. This research paper is the first to apply and implement medical decision-making tools as quality improvement activities. These proposed models will help quality practitioners to enhance the process and product quality level.

A Method of Rating Curve Adjustment (수위유량곡선보정방법에 대하여)

  • 박정근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.2
    • /
    • pp.4116-4120
    • /
    • 1976
  • With the use of many rivers increased nearly to the capacity, the need for information concerning daily quantities of water and the total annual or seasonal runoff has became increased. A systematic record of the flow of a river is commonly made in terms of the mean daily discharge Since. a single observation of stage is converted into discharge by means of rating curve, it is essential that the stage discharge relations shall be accurately established. All rating curves have the looping effect due chiefly to channel storage and variation in surface slope. Loop rating curves are most characteristic on streams with somewhat flatter gradients and more constricted channels. The great majority of gauge readings are taken by unskilled observers once a day without any indication of whether the stage is rising or falling. Therefore, normal rating curves shall show one discharge for one gauge height, regardless of falling or rising stage. The above reasons call for the correction of the discharge measurements taken on either side of flood waves to the theoretical steady-state condition. The correction of the discharge measurement is to consider channel storage and variation in surface slope. (1) Channel storage As the surface elevation of a river rises, water is temporarily stored in the river channel. There fore, the actual discharge at the control section can be attained by substracting the rate of change of storage from the measured discharge. (2) Variation in surface slope From the Manning equation, the steady state discharge Q in a channel of given roughness and cross-section, is given as {{{{Q PROPTO SQRT { 1} }}}} When the slope is not equal, the actual discharge will be {{{{ { Q}_{r CDOT f } PROPTO SQRT { 1 +- TRIANGLE I} CDOT TRIANGLE I }}}} may be expressed in the form of {{{{ TRIANGLE I= { dh/dt} over {c } }}}} and the celerity is approximately equal to 1.3 times the mean watrr velocity. Therefore, The steady-state discharge can be estimated from the following equation. {{{{Q= { { Q}_{r CDOT f } } over { SQRT { (1 +- { A CDOT dh/dt} over {1.3 { Q}_{r CDOT f }I } )} } }}}} If a sufficient number of observations are available, an alternative procedure can be applied. A rating curve may be drawn as a median line through the uncorrected values. The values of {{{{ { 1} over {cI } }}}} can be yielded from the measured quantities of Qr$.$f and dh/dt by use of Eq. (7) and (8). From the 1/cI v. stage relationship, new vlues of 1/cI are obtained and inserted in Eq. (7) and (8) to yield the steady-state discharge Q. The new values of Q are then plotted against stage as the corrected steadystate curve.

  • PDF

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

A Frequency Domain Analysis of Corneal Deformation by Air Puff (Air puff에 의한 각막 변형의 주파수 영역 분석)

  • Hwang, Ho-Sik;Lee, Byeong Ha;Lee, Chang Su
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2014
  • Intraocular pressure is measured after a cornea air puff by observing biomechanical properties such as thickness or displacement of the cornea. In this paper, we deal with a frequency domain analysis of corneal deformation in the air puff tonometry that is used to diagnose glaucoma or lasik. We distinguish the patient from the normal by measuring the oscillation frequency in the neighborhood of the central cornea section. A binary image was obtained from the video images, and cornea vertical oscillation profile was extracted from the difference between the vertical displacement data and the curve fitting. In terms of Fourier transform, a vibration frequency of 479.2Hz for the patient was obtained as well as more higher 702.8Hz for the normal due to stiffness. Hilbert-Huang transform's empirical mode decomposition generally describes local, nonlinear, and nonstationary data. After the data were decomposed into intrinsic mode functions, a spectrum and power were analysed. Finally, we confirm that the patient has 6 times more higher power ratio for the specific intrinsic mode function between the patient and the normal.

Quantitative Comparison of Computed Radiography and Film Radiography in Detection of Peritoneal Effusion in Dogs (개에서 실험적으로 복수를 유발한 후, 컴퓨터 촬영술과 필름 촬영술을 이용한 복수량의 정량적 비교)

  • Kim, Ju-Hyung;Kim, Tae-Hun;Chang, Jin-Hwa;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.284-288
    • /
    • 2010
  • The aim of this report is to compare quantitatively computed radiography (CR) and screen-film radiography (SFR) in the detection of peritoneal effusion in dogs. Normal four beagle dogs and one Maltese dog were used. Each five CR and SFR abdominal images of right lateral and ventro-dorsal position were obtained after lodge of 6 ml, 8 ml, 12 ml, 15 ml, and 18 ml of normal saline by intraperitoneal injection within the abdomen. The reviewers were asked to evaluate each SFR and CR images for the presence of peritoneal effusion using the score by the presence of a peritoneal effusion on a five-point ordinal scale. A receiver operating curve (ROC) analysis compared the two imaging modalities. The present study showed that there was no statistical difference between SFR and CR in the detecting peritoneal effusion, but CR was relatively more sensitive based on the increased area under its ROC analysis. Moreover, Readers were more likely to detect peritoneal effusion on CR images than SFR.

The estimation of river discharge by using the mean velocity equation in a unsteady condition (평균유속공식을 이용한 부정류 하천유량 산정)

  • Choo, Tai Ho;Chae, Soo Kwon;Yoon, Hyeon Cheol;Yun, Gwan Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6558-6564
    • /
    • 2013
  • As the average indicator for amount of water flowing in any cross section of a river, the mean discharge has been reported to be a very important factor for examining water circle constructions in a river basin, the design and construction of a hydraulic structure, and water front area use and management. The stage-discharge curve based on discharge and stage data measured in a normal season were basically derived. Using this derivation, the necessary discharge data was obtained. The values produced in this manner corresponded to the measured data in a uniform flow state well, but showed limited accuracy in a flood season (unsteady flow). In the present paper, the mean velocity in unsteady flow conditions, which exhibited loop form properties, was estimated using the new mean velocity formula derived from Chiu's 2-D velocity. The results of RMSE and Polar graph analyses showed that the proposed equation exhibited approximately nineteen times the accuracy compared to the Manning and Chezy equations.