• Title/Summary/Keyword: Normal operation

Search Result 2,146, Processing Time 0.031 seconds

Cellular Automata and It's Applications

  • Lee, Jun-Seok;Cho, Hyun-Ho;Rhee, Kyung-Hyune
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.4
    • /
    • pp.610-619
    • /
    • 2003
  • This paper presents a concept of cellular automata and a modular exponentiation algorithm and implementation of a basic EIGamal encryption by using cellular automata. Nowadays most of modular exponentiation algorithms are implemented by a linear feedback shift register(LFSR), but its structure has disadvantage which is difficult to implement an operation scheme when the basis is changed frequently The proposed algorithm based on a cellular automata in this paper can overcome this shortcomings, and can be effectively applied to the modular exponentiation algorithm by using the characteristic of the parallelism and flexibility of cellular automata. We also propose a new fast multiplier algorithm using the normal basis representation. A new multiplier algorithm based on normal basis is quite fast than the conventional algorithms using standard basis. This application is also applicable to construct operational structures such as multiplication, exponentiation and inversion algorithm for EIGamal cryptosystem.

  • PDF

Ground High/Low Temperature Test for FA-50 Aircraft (FA-50 경공격기 전기체 지상 고/저온시험)

  • Ahn, Jong Hoon;Kim, Tae Ho;Woo, Seung Cheol;Cho, Young Kyun;Kim, Do Wan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

Self-Testing for FFT processor with systolic array architecture (시스토릭 어레이 구조를 갖는 FFT 프로세서에 대한 Self-Testing)

  • Lee, J.K.;Kang, B.H.;Choi, B.I.;Shin, K.U.;Lee, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1503-1506
    • /
    • 1987
  • This paper proposes the self test method for 16 point FFT processor with systolic array architecture. To test efficiently and solve the increased hardware problems due to built-in self test, we change the normal registers into Linear Feedback Shift Registers(LFSR). LFSR can be served as a test pattern generator or a signature analyzer during self test operation, while LFSR a ordering register or a accumulator during normal operation. From the results of logic simulation for 16 point FFT processor by YSLOG, the total time is estimated in about. 21.4 [us].

  • PDF

IGRINS Operation Plan and the status of the IGRINS Reduction Pipeline

  • Lee, Jae-Joon;Hwang, Narae;Park, Byeong-Gon;Yuk, In-Soo;Park, Chan;Le, Huynh Anh N.;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.94.2-94.2
    • /
    • 2014
  • After successful commissioning observations, IGRINS will soon begin its normal scientific operations on the 2.7m Harlan J. Smith telescope at the McDonald Observatory. We will present a working version of the IGRINS operation plan. A fraction of IGRINS guaranteed time will be devoted to a selection of strategic programs with legacy values, whereas the rest of the time will be used for normal programs. We will also describe the current status of the IGRINS data reduction pipeline package and its future development plan.

  • PDF

A Study on the Dressing Conditions of Diamond Wheel (다이아몬드휠의 드레싱 조건에 관한 연구)

  • 하상백;정재극;이종찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.1020-1024
    • /
    • 1997
  • Recently the use of ceramic materals has been greatly increased in the industries. But machining of the ceramics is quite unproductive because of their high stength,high hardness,and brittleness. The efficiency of the grinding operation of ceramics depends on the preparation of diamond grinding wheel, i.e.,truning and dressing. This paper describes some experimental results on the dressing conditions of diamond grinding wheel. The dressing performance is evaluated by the magnitude of normal grinding force. The better dressed wheels result in the lower normal grinding forces. The dressing performances of copper plate and aluminum oxide dressing stick are compared. The optimum dressing conditions including the grit size of dressing sticks, the depth of the dressing operation, and the dressing speed qre determined.

  • PDF

Quantitative evaluation of hepatic function for pre- and post-surgery patients using deconvolution technique in Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 외과적 수술 전후의 간의 정량적 평가)

  • Kim, S.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.366-369
    • /
    • 1997
  • In this study, we measured upper right, lower right, upper left region to find the optimal region which represent liver function. We found that the upper right region is optimal because of high accuracy and low standard deviation. For normal subjects all the calculated HEFs were greater than 100% and all those of abnormal ones were less than 80%. Thus HEF can be assumed to discriminate abnormal livers from normal ones. It was found that the patients with surgical operation would survive if both the pre-and the post-operative HEFs are greater than 50%. Therefore HEF method can be a good estimator for surgeon to determine the surgical operation and to evaluate remaining hepatic function after surgery as well as it is reliable and simple.

  • PDF

An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier (베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구)

  • Lee, Heung-Ju;Chang, Young-Soo;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.36-41
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. FDD algorithm can detect refrigerant leak failure, when 20% amount of charged refrigerant for normal operation leaks from the water chiller. The refrigerant leak failure caused COP reduction by 6.7% compared with normal operation performance. When two kinds of faults, such as a decrease in the mass flow rate of cooling water and temperature sensor fault of cooling water inlet, are detected, COP is a little decreased by these faults.

  • PDF

A Comparison Study on the Design of Dynamic Response appears on Bridge as operation of Light Railway Train (경량전철 주행 시 교량에 발생하는 동적응답 설계 비교 연구)

  • Yeon, Sang-Ho;Kang, Sung-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.86-92
    • /
    • 2008
  • AGT system is a kind of light railway train. AGT system use of concrete track and rubber tire, so it can be reduce the noise and vibration, compare to the normal train system. And, the dynamic responses of normal bridge are influenced by the dynamic characteristics of bridge, the speed of vehicle and the surface roughness of railway. But the AGT system bridge is influenced not only the above facts but also the guiderail unevenness, because, AGT vehicle steered by guiderail. So, in this study, optimized service condition is suggested for the design and operation of AGT system, by the means of experimental study. The experiments are executed for PSC bridge with length of 30m, at the AGT test line in Kyongsan. The test results are compared and investigated according to the prominence. In the test result, the guiderail prominence influenced on the dynamic response of bridge. It shows a increase as compared with no guiderail prominence in the dynamic response value acceleration, displacement, stain.

  • PDF

Stroke Analysis of Large Bore Hydraulic Snubber Supporting Reactor Coolant System (원자로 냉각재 계통을 지지하는 대구경 유압식 스너버의 이동거리 해석)

  • 이상호;윤기석;전장환;박명규;엄세윤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.61-67
    • /
    • 1995
  • The steam generator, one of the major components in the reactor coolant system, plays an important role in transferring the thermal energy made in the reactor during normal operation to the secondary side and producing steam to drive turbine. A hydraulic snubber system is used in order to protect the steam generator under the dynamic loading condition and to absorb the thermal expansion transmitted by the reactor coolant piping due to high temperature and pressure during normal operation. In this study, the model for a geometrical linkage system is presented to analyze the snubber stroke of the steam generator and the parameters in the snubber stroke analysis are investigated. A method to analyze lever ratio of the linkage system which is required in the process of determining the snubber stiffness value is also presented. To discuss the validation of the suggested analysis, the analysis results are compared with the measured data during the hot functional test for the standardized 1000 Mwe pressurized water reactor plant under the construction.

  • PDF

Islanding Detection Based on Complex Power at the Intertie (연계점에서의 복소전력을 이용한 단독운전 판단기법)

  • Kang, Yong-Cheol;Cha, Sun-Hee;Jang, Sung-Il;Kang, Hae-Gweon;Kim, Yong-Gyun;Park, Goon-Cherl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2167-2172
    • /
    • 2008
  • A large scale embedded generator or a micro-grid is usually interconnected to the grid through the dedicated line. Immediately after the removal of the grid supply, it must be disconnected and remain disconnected until the normal grid supplies are restored. This paper proposes an islanding detection algorithm based on complex power at the intertie. Complex power at the intertie delivered to the grid has a value depending on power flow during normal operation. When loss of mains occurs, complex power at the intertie moves to a value depending on the parameters of the dedicated line. The performance of the proposed algorithm was investigated under various operating and fault conditions. The proposed algorithm can detect an islanding operation even if no power is exchanged prior to loss of mains and discriminate the fault condition from islanding.