• Title/Summary/Keyword: Normal direction

Search Result 1,131, Processing Time 0.029 seconds

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Monte-Carlo Simulations of Non-ergodic Solute Transport from Line Sources in Isotropic Mildly Heterogeneous Aquifers (불균질 등방 대수층 내 선형오염원으로부터 기원된 비에르고딕 용질 이동에 관한 몬테카를로 시뮬레이션)

  • Seo Byong-min
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.20-31
    • /
    • 2005
  • Three dimensional Monte-Carlo simulations of non-ergodic transport of a lion-reactive solute plume by steady-state groundwater flow under a uniform mean velocity in isotropic heterogeneous aquifers were conducted. The log-normally distributed hydraulic conductivity, K(x), is modeled as a random field. Significant efforts are made to reduce tile simulation uncertainties. Ensemble averages of the second spatial moments of the plume and plume centroid variances were simulated with 1600 Monte Carlo runs for three variances of log K, ${\sigma}_Y^2=0.09,\;0.23$, and 0.46, and three dimensionless lengths of line plume sources normal to the mean velocity. The simulated second spatial moment and the plume centroid variance in longitudinal direction fit well to the first order theoretical results while the simulated transverse moments are generally larger than the first order results. The first order theoretical results significantly underestimated the simulated dimensionless transverse moments for the aquifers of large ${\sigma}_Y^2$ and large dimensionless time. The ergodic condition for the second spatial moments is far from reaching in all cases simulated, and transport In transverse directions may reach ergodic condition much slower than that in longitudinal direction. The evolution of the contaminant transported in a heterogeneous aquifer is not affected by the shape of the initial plume but affected mainly by the degree of the heterogeneity and the size of the initial plume.

A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge (금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교)

  • Park, Jong-Min;Kim, Hee-Jung;Min, Je-Soon;Lee, Je-Hee;Park, Charn-Il;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • In order to evaluate the radio-protective advantage of an enhanced dynamic wedge (EDW) over a physical wedge (PW), we measured peripheral doses scattered from both types of wedges using a 2D array of ion-chambers. A 2D array of ion-chambers was used for this purpose. In order to confirm the accuracy of the device we first compared measured profiles of open fields with the profiles calculated by our commissioned treatment planning system. Then, we measured peripheral doses for the wedge angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;and\;60^{\circ}$ at source to surface distances (SSD) of 80 cm and 90 cm. The measured points were located at 0.5 cm depth from 1 cm to 5 cm outside of the field edge. In addition, the measurements were repeated by using thermoluminescence dosimeters (TLD). The peripheral doses of EDW were (1.4% to 11.9%) lower than those of PW (2.5% to 12.4%). At 15 MV energy, the average peripheral doses of both wedges were 2.9% higher than those at 6MV energy. At a small SSD (80 cm vs. 90 cm), peripheral dose differences were more recognizable. The average peripheral doses to the heel direction were 0.9% lower than those to the toe direction. The results from the TLD measurements confirmed these findings with similar tendency. Dynamic wedges can reduce unnecessary scattered doses to normal tissues outside of the field edge in many clinical situations. Such an advantage is more profound in the treatment of steeper wedge angles, and shorter SSD.

  • PDF

Characteristics of Subsurface Movement and Safety of the Songsanri Tomb Site of the Baekje Dynasty using Tiltmeter System (경사도변화 계측을 통한 백제 송산리 고분군의 지하 벽체거동특성과 안정성)

  • 서만철;박은주
    • The Journal of Engineering Geology
    • /
    • v.7 no.3
    • /
    • pp.191-205
    • /
    • 1997
  • Measurements on subsurface movement of the Songsanri tomb site including the Muryong royal tomb was conducted using a tiltmeter system for the period of 15 months form July 7, 1996 to September 30, 1997. Two coordinate tilt monitoring data shows the biggest movement rate of 2.3mm/m/yr toward south in the frontal wall(N-S tilt) of the Muryong royal tomb. Southward tilting of bricks above the southern fire place in the western wall of the Muryong royal tomb is a proof of southward tilting of the royal tomb since its excavation in 1971. The eastern wall of the Muryong royal tomb is also tilting toward inside the tomb with the rate of 1.523mm/m/yr. Furthermore, tilting rate of wall increases twice in rainy season. It is interpreted tbat infiltration of water into the tomb and nearby ground in rainy season results in dangerous status for the safety of tomb structure. On the whole, normal component tilting of the walls of the 5th tomb is large than its shear component. It shows a small displacement toward one direction without no abrupt change in its direction and amount of tilting. The tilting rate of walls of the 6th tomb is about 8.8mm/m/yr in the dry season which is much bigger than those of other tombs in rainy season. Deformation events of walls of the tombs are closely related to amount of precipitation and variation of temperature. In comparison with different weather conditions, tilting is much bigger during the period of rainy weather than sunny weather. It is interpreted that rainwater flew into the turm through faults and nearby ground. High water content in nearby ground resulted strength of ground. The tilting event of walls shows a hysterisis phenomenon in analysis of temperature effect on tilting event. The walls tilt rapidly with steep rising of temperature, but the tilted walls do not come back to original position with temperature falling. Therefore, a factor of steep increase of the temperature must be removed. It means the tomb have to be kept with constant temperature. The observation of groundwater level using three boreholes located in construction site and original ground represented that groundwater level in construction site is higher than that of original ground during the rainy season from the end of June to August. It means that the drainage system of the Muryong royal tomb is worse than original ground, and it is interpreted that the poor drainage system is related to safety of tomb structure. As above mentioned, it is interpreted that artificial changes of the tomb environment since the excavation, infiltration of rainwater and groundwater into the tomb site and poor drainage system had resulted in dangerous situation for the tomb structure. According to the result of the long period observation for the tomb site, it is interpreted that protection of the tomb site from high water content should be carried out at first, and the rise of temperature by means of the dehumidifier inside the tomb must be removed.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Spatial Variation Analysis of Soil Characteristics and Crop Growth accross the Land-partitioned Boundary I. Spatial Variation of Soil Physical Properties (구획경계선(區劃境界線)의 횡단면(橫斷面)에 따른 토양특성(土壤特性)과 작물생육(作物生育)에 관한 공간변이성(空間變異性) 분석(分析) 연구(硏究) I. 토양물리성(土壤物理性)의 공간변이성(空間變異性))

  • Park, Moo-Eon;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.3
    • /
    • pp.163-172
    • /
    • 1989
  • In order to study spatial variability of soil physical properties accross the land-partitioned boundary on Hwadong silt clay loam soil (Fine clayey, mixed, mesic family of Aquic Hapludalfs), all measured data were analyzed by means of kriging, fractile diagram, smooth frequency distribution, and autocorrelation. Sampling for soil particle size distribution analysis was made at 225 intersections of $15{\times}15$ grid with 10m interval. Field capacity, bulk density and saturated hydraulic conductivity were measured in situ at 594 intersections of $33{\times}18$ grid with 2.5m interval in only $6,000m^2$ reselected from $22,500m^2$ of sampling area for particle size distribution analysis. Sampled or measured soil depths were 0 to 10cm 25 to 35cm and 50 to 60cm at each intersections. The results are summarized as follows: 1. The coefficient of variance (CV) of various physical properties ranges from 4.8 to 128.8%. Saturated hydraulic conductivity is classified into the high variation group with CV greater than 100%, while the low variation group with CV smaller than 10% consists of bulk density. Other properties belong to the medium variation group with CV between 10 and 100%. 2. The appropriate number of soil samples for the determination of various physical properties with error smaller than 10% are calculated as one for bulk density, six for field moisture capacity, 16 for silt, 19 for clay, 69 for sand and 686 for saturated hydraulic conductivity. 3. Smooth frequency distribution and fractile diagram show that saturated hydraulic conductivity is in lognormal distribution while other physical properties are in normal distribution. 4. Serial correlation analysis reveals that the soil physical properties have spatial dependence between two nearest neighbouring grid points. Autocorrelation analysis of physical properties measured between the serial grid points in the direction of south to north following section boundary shows that the zone of influence showing stationarity ranges from 7.5 to 40m. In the direction of east to west across section boundary, the autocorrelogram of many physical properties shows peaks with the periodic interval of 30m, which are similar to the partitioned land width. This reveals that the land-partitioned boundary causes soil variability.

  • PDF

Numerical Study on Spring-Neap Variability of Net Volume Transport at Yeomha Channel in the Han River Estuary (한강하구 수로별 순 수송량과 대.소조기 변화에 따른 염하수로의 순 수송량 변동에 관한 수치해석적 연구)

  • Yoon, Byung-Il;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.4
    • /
    • pp.257-268
    • /
    • 2012
  • The EFDC model with find grid resolution system connecting the Gyeong-Gi bay and Han River estuary was constructed to study on spring-neap variability of net volume transport at each channel of the Han River estuary. The simulation time of numerical model is 124 days from May to August, 2009 with freshwater discharge at Han, Imjin and Yeseong River. The calibration and verification of model results was confirmed using harmonic components of water level and tidal current. The net volume transport was calculated during 30 days with normal freshwater conditions at Seokmo channel and Yeomha channel around Ganghwado. The ebbing net volume transport of 44% and 56% is drained into Gyeong-Gi bay through Yeomha and Seokmo channel, respectively. The ebbing net volume transport nearby Seodo at Yeomha channel convergence flooding net volume transport at Incheon harbor, and drain (westward direction) through channel of tidal flat between Ganghwado and Yeongjongdo to the Gyeong-Gi bay. The averaged net volume transport during 4 tidal cycles was compared to variation of spring-neap periods of the Yeomha channel. The convergence position is moved up- and down-ward according to spring-neap variability. The movement of the convergence zone is appeared because 1) increasing of discharged rate tidal flat channel between Ganghwado and Yeongjongdo at the spring period, 2) The growth of barotropic forcing with downward direction at the spring tide, and 3) The strength of the baroclinic pressure gradient is greater than spring with mixing processes.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

A Study of Segmental and Syllabic Intervals of Canonical Babbling and Early Speech

  • Chen, Xiaoxiang;Xiao, Yunnan
    • Cross-Cultural Studies
    • /
    • v.28
    • /
    • pp.115-139
    • /
    • 2012
  • Interval or duration of segments, syllables, words and phrases is an important acoustic feature which influences the naturalness of speech. A number of cross-sectional studies regarding acoustic characteristics of children's speech development found that intervals of segments, syllables, words and phrases tend to change with the growing age. One hypothesis assumed that decreases in intervals would be greater when children were younger and smaller decreases in intervals when older (Thelen,1991), it has been supported by quite a number of researches on the basis of cross-sectional studies (Tingley & Allen,1975; Kent & Forner,1980; Chermak & Schneiderman, 1986), but the other hypothesis predicted that decreases in intervals would be smaller when children were younger and greater decreases in intervals when older (Smith, Kenney & Hussain, 1996). Researchers seem to come up with conflicting postulations and inconsistent results about the change trends concerning intervals of segments, syllables, words and phrases, leaving it as an issue unresolved. Most acoustic investigations of children's speech production have been conducted via cross-sectional designs, which involves studying several groups of children. So far, there are only a few longitudinal studies. This issue needs more longitudinal investigations; moreover, the acoustic measures of the intervals of child speech are hardly available. All former studies focus on word stages excluding the babbling stages especially the canonical babbling stage, but we need to find out when concrete changes of intervals begin to occur and what causes the changes. Therefore, we conducted an acoustic study of interval characteristics of segments and words concerning Canonical Babble ( CB) and early speech in an infant aged from 0;9 to 2;4 acquiring Mandarin Chinese. The current research addresses the following two questions: 1. Whether decreases in interval would be greater when children were younger and smaller when they were older or vice versa? 2. Whether the child speech concerning the acoustic features of interval drifts in the direction of the language they are exposed to? The female infant whose L1 was Southern Mandarin living in Changsha was audio- and video-taped at her home for about one hour almost on a weekly basis during her age range from 0;9 to 2;4 under natural observation by us investigators. The recordings were digitized. Parts of the digitized material were labeled. All the repetitions were excluded. The utterances were extracted from 44 sessions ranging from 30 minutes to one hour. The utterances were divided into segments as well as syllable-sized units. Age stages are 0;9-1;0,1;1-1;5, 1;6-2;0, 2;1-2;4. The subject was a monolingual normal child from parents with a good education. The infant was audio-and video-taped in her home almost every week. The data were digitized, segments and syllables from 44 sessions spanning the transition from babble to speech were transcribed in narrow IPA and coded for analysis. Babble was coded from age 0;9-1;0, and words were coded from 1;0 to 2;4, the data has been checked by two professionally trained persons who majored in phonetics. The present investigation is a longitudinal analysis of some temporal characteristics of the child speech during the age periods of 0;9-1;0, 1;1-1;5, 1;6-2;0, 2;1-2;4. The answer to Research Question 1 is that our results are in agreement with neither of the hypotheses. One hypothesis assumed that decreases in intervals would be greater when children were younger and smaller decreases in intervals when older (Thelen,1991); but the other hypothesis predicted that decreases in intervals would be smaller when children were younger and greater decreases in intervals when older (Smith, Kenney & Hussain, 1996). On the whole, there is a tendency of decrease in segmental and syllabic duration with the growing age, but the changes are not drastic and abrupt. For example, /a/ after /k/ in Table 1 has greater decrease during 1;1-1;5, while /a/ after /p/, /t/ and /w/ has greater decrease during 2;1-2;4. /ka/ has greater decrease during 1;1-1;5, while /ta/ and /na/ has greater decrease during 2;1-2;4.Across the age periods, interval change experiences lots of fluctuation all the time. The answer to Research Question 2 is yes. Babbling stage is a period in which the children's acoustic features of intervals of segments, syllables, words and phrases is shifted in the direction of the language to be learned, babbling and children's speech emergence is greatly influenced by ambient language. The phonetic changes in terms of duration would go on until as late as 10-12 years of age before reaching adult-like levels. Definitely, with the increase of exposure to ambient language, the variation would be less and less until they attain the adult-like competence. Via the analysis of the SPSS 15.0, the decrease of segmental and syllabic intervals across the four age periods proves to be of no significant difference (p>0.05). It means that the change of segmental and syllabic intervals is continuous. It reveals that the process of child speech development is gradual and cumulative.

Study of silk lousiness (I) (견사 Lousiness에 대한 연구 (I))

  • 최병희;김낙정;박광의;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.3
    • /
    • pp.1-11
    • /
    • 1963
  • This treatise is to set up a fundamental condition of checking silk lousiness and to set up a new improving method of cocoon bave lousiness after super refining treatment. It is also studied whether silk lousiness can be eliminated through the observation of the silk gland, or the lousiness can be able to improve through such a study. The conclusions obtained in this paper are as follows. 1. Silk lousiness is able to be observed most properly when the light direction and the fiber direction are parallel in plan view of the silk cloth and the greater the angle between them is, the less the lousiness is observed. When, however, the angle is greater than some specific angle(30$^{\circ}$), no more lousiness is observed. This specific angle is named by the author as Lousiness Horizontal Critical Angle. 2. Silk lousiness can be observed when the angle of light incidence against the silk cloth is six degrees, while the larger the angle is, the less the lousiness is observed. When, however, the angle is greater than same specific angle(45$^{\circ}$) the lousiness disappears. Such a specific angle is named by the author as Lousiness Vertical Critical Angle. 3. The best textile composition to decrease lousiness defect is plan weave, while twill and satin weave show more lousiness with the same silk fiber. 4. Lousiness was classified as Lousiness A, B, ana C of which A was the general lousiness, B was the group type, and C was the glucose type and the standard photographs for the lousiness grading of these types were prepared. 5. The proper soap-refining hours of silk for lousiness test was eight hours. 6. The greater the difference of fiber diameter between the cocoon single bave and the splitend was, the more lousiness was composed. The normal splitends were measured as 1/4-1/5 of the main fiber. 7. The lousiness was found at the cocoon shape ends more than other parts, and found at the middle cocoon layer than other layer which was imagined to be as a result of poor uniform bave spinning of silk worm. 8. Female cocoon had more lousiness than the male cocoon. 9. It was found that there was a great possibility to have the splitends through the observation of the anatomical silkgland, and the author reached a conclusion that the lousiness can be improved to a certain degree only by the elimination of abnormal silk gland from the breeding aspects. 10. The cocoon bave of the offspring after super refining lousiness test and selection showed more improved lousiness defect than that of the parents.

  • PDF