Communications for Statistical Applications and Methods
/
v.7
no.2
/
pp.371-383
/
2000
Lindsay (1994) and Basu et al (1997) show that another density-based distance called the negative exponential disparity (NED) is an excellent competitor to the Hellinger distance (HD) in generating an asymptotically fully efficient and robust estimator. Bhattacharya and Basu (1996) consider estimation of the locations of several normal populations when an order relation between them is known to be true. They empirically show that the robust HD based weighted likelihood estimators compare favorably with the M-estimators based on Huber's $\psi$ function, the Gastworth estimator, and the trimmed mean estimator. In this paper we investigate the performance of the weighted likelihood estimator based on the NED as a robust alternative relative to that based on the HD. The NED based estimator is found to be quite competitive in the settings considered by Bhattacharya and Basu.
Communications for Statistical Applications and Methods
/
v.10
no.3
/
pp.749-764
/
2003
In this paper we explain that normal theory likelihood-ratio tests(z, t, $x^2$. F) for mean(s) or variance(s) can be geometrically related to volume of difference of two joint pdf's. One is an estimated joint pdf under null parameter space $\omega$ and the other is an estimated joint pdf under full parameter space $\Omega$. For explanations, ‘distance between two distributions’ is defined. We study properties of it, and derive some results on the distance between two multivariate normal distributions.
Background: Shoulder horizontal adduction (HA) is performed in many activities of daily living. The limited range of motion (LROM) of HA is affected by the tightness of the posterior deltoid, infraspinatus, teres major, and posterior capsule of glenohumeral joint. The LROM of shoulder HA contributes to excessive scapular abduction. Objects: The aim of this study is to compare the scapular abduction distance and three-dimensional displacement of the scapula during shoulder horizontal adduction between subjects with and without the LROM of shoulder HA. Methods: 24 subjects (12 people in LROM group and 12 people in normal ROM group) participated. Subjects with less than $115^{\circ}$ of HA ROM were included in LROM group. Shoulder HA was performed 3 times for measuring scapular abduction distance and three-dimensional displacement of the scapula. Tape measure was used for measuring scapular abduction distance. Scapular abduction distance was normalized by dividing the scapular size. Polhemus Liberty was used for measuring the three-dimensional displacement of the scapula. Results: Normalized scapular abduction distance was significantly greater in LROM group than normal ROM group (p<.001). Three-dimensional displacement of the scapula during shoulder HA was greater in LROM group than normal ROM group (p<.05). Conclusion: LROM group had a greater scapular abduction and three-dimensional displacement of the scapula during shoulder HA compared to normal ROM group.
Journal of the Korean Society of Physical Medicine
/
v.6
no.4
/
pp.397-406
/
2011
Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.
Journal of Korean Society of Coastal and Ocean Engineers
/
v.17
no.4
/
pp.221-231
/
2005
The present study is deeply concerned with the reliability design method(Level III) for caisson breakwaters using expected sliding distance, and the objectives of this study are to propose the employment of a doubly-truncated normal distribution and to present the validity for it. In this study, therefore, the explanations are made for consideration of effects of uncertain factors, and a clear basis that the doubly-truncated normal distribution should be employed in the computation process of expected sliding distance by Monte-Carlo simulation is presented with introduction of the employment method. Even though only caisson breakwaters are treated in this paper, the employment of doubly-truncated normal distribution can be applied to various coastal structures as well as other engineering fields, and therefore it is expected that the present study will be extended in various fields.
Journal of information and communication convergence engineering
/
v.13
no.2
/
pp.74-80
/
2015
In cognitive radios, spectrum sensing plays an important role in accurately detecting the presence or absence of a licensed user. However, the intervention of malicious users (MUs) degrades the performance of spectrum sensing. Such users manipulate the local results and send falsified data to the data fusion center; this process is called spectrum sensing data falsification (SSDF). Thus, MUs degrade the spectrum sensing performance and increase uncertainty issues. In this paper, we propose a method based on the Hausdorff distance and a similarity measure matrix to measure the difference between the normal user evidence and the malicious user evidence. In addition, we use the Dempster-Shafer theory to combine the sets of evidence from each normal user evidence. We compare the proposed method with the k-means and Jaccard distance methods for malicious user detection. Simulation results show that the proposed method is effective against an SSDF attack.
In order to find the causes of velopharyngeal incompetency after primary palatorrhaphy in cleft patients, we analyzed the form and function of the velopharyngeal space of fifteen operated cleft palate patients and five normal subjects. The velopharyngeal function was evaluated by lateral cephalometric radiography, velopharyngography and hypernasality cul-de-sac test. The obtained results were as follows. 1. The rate of velopharyngeal incompetency was twenty percent, three of the fifteen operated patients. Two of them were complete cleft palate and the other was incomplete one. 2. The length of soft palate and levator eminence were longer in normal group than those of good speech group and complete cleft palate group during phonation of /i/ (P<0.05). The lengthening rate of soft palate was smaller in good and poor speech group than that of normal group(P<0.05), and, reduced in order, normal group, complete cleft palate group and incomplete palate group(P<0.05). 3. The nasopharyngeal distance had no significant difference between all groups at rest, but, smaller in normal group than that of both cleft palate group(P<0.05), good speech group and poor speech group(P<0.05) during phonation of /i/ The difference in nasopharyngeal distance between rest and /i/ phonation was greater in normal group than that of both cleft palate group, good speech group and poor speech group. 4. The moving distance of sop palate reduced in order, normal group, incomplete cleft palate group, complete cleft palate group(P<0.05). 5. The distance between lateral pharyngeal wall had no significant difference between all groups in rest, but, smaller than that of complete cleft palate group in normal group(P<0.01) and increased in order normal group, good speech group, poor speech group(P<0.01) during phonation of /a/. The mobility of lateral wall was reduced in order, normal group, good speech group poor speech group(P<0. 01). 6. There was low corelationship between the mobility of lateral pharyngeal wall and soft palate. Therfore, it suggest that the movements of lateral pharyngeal wall and soft palate occurs independently.
Kim, Jong-Min;Kim, Jin-Ju;Park, Su-Yeon;Cha, Jae-Hyeon;Kim, Min-Jung;Kim, Jin-A
Journal of Korean Clinical Health Science
/
v.5
no.1
/
pp.816-824
/
2017
Purpose. This study was classified into normal and demented elderly through K-MMSE. The purpose of this study was to analyze gait characteristics of normal elderly and demented peoples using GAITRite walking system. Methods. The subjects of this study were selected as elderly people receiving home visit physical therapy. An independent t-test was conducted to verify the statistical significance of the time-space variables of the elderly with dementia. Results. Step time(p=0.041), cycle time(p=0.037), distance(p=0.024), and cadence(p=0.048) were significantly shorter in the normal elderly than in the demented elderly on flat place. The mean age was significantly longer in normal elderly than in elderly persons with dementia. Step time(p=0.022), cycle time(p=0.023), distance(p=0.019), and cadence(p=0.015) were significantly shorter in the mat walking. The mean age was significantly longer in normal elderly than in elderly patients with dementia. Stretch time, cycle time, distance, and hair support time were significantly shorter in the mat walking. The mean age of the elderly was significantly longer than that of the elderly with dementia. The spinal support time, which is a spatial variable, was significantly shorter in the normal elderly than in the demented elderly. Conclusions. It compares the various gait characteristics of the normal and demented elderly people, thereby increasing the walking ability of the elderly person more effectively. This study should be utilized as basic data for preventing fall-down.
The Transactions of The Korean Institute of Electrical Engineers
/
v.64
no.2
/
pp.353-356
/
2015
Due to high oil prices, environmental pollution, the study of electric vehicles have been actively promoted. Charger for the electric vehicle is being developed using wireless rather than cable options. In this paper, we got more efficiency from using a superconducting transmission coil compared to using a normal coil. We implemented a wireless power transmission system using a magnetic induction at a frequency of 63.1 kHz. For comparison, a transmitter was designed using a superconducting coil and a normal coil. In addition, a receiver used a normal coil to apply for electric vehicles. The applied voltage and current were12 V and 5 A. Efficiency at a distance of 40 ~ 80 mm was measured. As a result, the superconducting transmission coil had a higher efficiency than the normal transmission coil. However, the receiving coil should be normal conductor for stable operation considering that it was put in moving electric vehicle. The efficiency was increased to 44 % at a distance of 40 mm when the diameter of normal receiving coil was 120 mm.
This study was performed to investigate the morophological and positional correlation between the upper cervical vertebra, the oral structures and the pharyngeal tissues, and the correlation of these anatomical structures with dental features, such as teeth wear area nad tooth contact status, etc. Seventy patients with temporamandibular disorders and sixty three dental students without any signs and symptoms in head and neck region were selected for this study. All they had natural dentition without any fixed and removable protheses. Teeth wear area and arch width wre measured from the upper dental cast, tooth contact status were observed by T-Scan system$^\textregistered$ and four cephaloradiograpohs were taken from four head postures, namely, natural(NHP), forward(FHP), upward(UHP), and downward head postiure(DHP). 22 cephalometric items were measured on the films and the data were processed with SAS statistical program. The result of this study were as follows : 1. In normal group, angle of cervical vertebra tangent and of between hard and soft palate were broader in female subjects than those in male subjacets, but distance from subocciput to axis, size of soft palate, and pharyngeal space width were larger in male subjects. 2. In normal group with natural head posture, the items correlated each others from the three anatomical regions were distance between first nad second vertebra in posterior part, distance from the lingual surface of lower anterior teeth to anterior surface of soft palate, and distance from the hyoid bone to third vertebra. 3. Three set of items showed significant correlation each other in the four head postures in normal group. First set was the angle between hard and soft palate and the idstance from subocciput to posterior arch of first vertebra, second set was the distance between first and second vertebra in posterior part and the teeth wear area, third set was number and force of tooth contact and length of soft palate and distance from anterior tip of hyoid bone to mandibular plane.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.