• 제목/요약/키워드: Noninvasive technique

검색결과 89건 처리시간 0.03초

Gamma Knife Radiosurgery for Vestibular Schwannomas

  • Lim, Young-Jin;Choi, Seok-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권3호
    • /
    • pp.159-167
    • /
    • 2007
  • Vestibular schwannoma (VS) is a benign tumor typically originated in the schwann cell of vestibular nerve and usually accompany hearing symptom. Microsurgical removal and radiosurgery have a great role for the treatment of VS. Recently radiosurgery has been considered as an alternative or primary treatment for VS with the tremendous increase of patients who were treated with gamma knife radiosurgery (GKS) though microsurgery still takes the premier. By many published results, it is proved that GKS is a effective and noninvasive technique for VS, especially small sized tumors with satisfactory tumor control rate. The authors assumed that GKS can be expected to achieve satisfactory tumor control rate for small VS under 5cc in volume. A major interest regarding radiosurgery nowadays is to determine the optimal radiation dose for hearing preservation to improve the quality of life of patients. The more high radiation dose are used for effective tumor growth control, the more radiation-related complications like as hearing deficit, the impairment of other cranial nerve function are increased. Since 1990's the mean radiation dose for tumor margin was more than 18 Gy, but there were high complication rate in spite of good tumor growth control. After the year of 2000, under the influence of advanced neuro-imaging techniques and radiosurgical planning system which enable clinicians to do more precise planning, marginal dose for VS has been decreased to 12-13 Gy and the radiation-related complications has been reduced. But because there may be a unexpected radiation induced complications as time goes by after the latency period, optimal radiation dose for VS should be established on the basis of more long term follow-up observation.

비협조적인 아동의 치과 치료를 위한 정주 진정요법 (INTRAVENOUS SEDATION FOR UNCOOPERATIVE DENTAL CHILD PATIENTS)

  • 박용규;김종수;김승오
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.710-716
    • /
    • 2006
  • 소아치과에서 진정요법은 치과 환경에 대하여 공포를 가진 아동, 협조 전 단계의 아동, 장애를 가진 아동 그리고 구토반사 등을 보이는 환자에게 사용될 수 있다. 본 증례에서는 다발성 치아 우식증을 주소로 본원에 내원한 환아에서 1.0mg/kg 케타민과 $0.03{\sim}0.06mg/kg$ 미다졸람 그리고 아트로핀 정주 병용투여 하에 수복치료를 시행하였다. 치료시간의 연장과 적절한 진정 상태 유지를 위하여 케타민(0.33mg/kg)과 미다졸람 $1mg(0.03{\sim}0.05mg/kg)$을 혼합하거나 각각 추가 투여하였다. 지속적으로 환자의 활력징후를 관찰하면서 약물의 추가투여 용량을 결정하였다. 모니터링 장비로 맥박 산소 측정법(pulse oximetry), 전자심전도(electrocardiogram), 비혈관식혈압(NIBP : Noninvasive Blood Pressure)을 사용하여 맥박, 호흡수, 혈압, 산소 포화도 등을 측정하였다. 진료 과정동안 안전을 위해 미국 소아치과 학회(American Academy of Pediatric Dentistry ; AAPD)의 권고 사항을 준수하였다.

  • PDF

Clinical Applications of 3T MR Spectroscopy

  • Choe, Bo-Young;Baik, Hyun-Man;Chu, Myung-Ja;Jeun, Sin-Soo;Kang, Sei-Kwon;Chung, Sung-Taek;Park, Chi-Bong;Oh, Chang-Hyun;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.345-351
    • /
    • 2002
  • The purpose of this study was to assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating brain tumor malignancy at 3T high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxe1 technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67${\pm}$018 and 1.16${\pm}$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (p=0.005), but Cho/Cr ratio of all tumor tissue was significantly higher (p=0.001). Cho/Cr ratio of high-grade gliomas was significantly higher than that of low-grade gliomas (P=0.001). Except 4 menigiomas, lactate signal was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. Our results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Diagnostic Accuracy of Magnetic Resonance Imaging versus Clinical Staging in Cervical Cancer

  • Shirazi, Ahmad Soltani;Razi, Taghi;Cheraghi, Fatemeh;Rahim, Fakher;Ehsani, Sara;Davoodi, Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권14호
    • /
    • pp.5729-5732
    • /
    • 2014
  • Background: Cervical cancer is the third most common gynecological cancer and a widespread malignancy in women, accounting for a large proportion of the cancer burden in developing countries. We compared accuracy of MRI staging with clinical staging and also concordance between the two methods for newly diagnosed patients with cervical cancer, using clinical staging as the reference. Materials and Methods: This prospective study was conducted on 27 newly diagnosed patients with cervical cancer from Imam Khomeini hospital from June 2012 to Feb 2014. New cases of cervical cancer with positive PAP test were staged separately with a clinical exam based on the FIGO system by a gynecologist, oncologist and also with MRI by an expert radiologist. Then we compared the predicted stage for each patient with the two methods. Results: Based on clinical staging 9 patients (33%) were observed at stage 1. MRI staging was in coordination with clinical staging in eight of them and for one patient MRI accorded stage 2B (88% concordance). Conclusions: MRI is a reliable noninvasive method with high accuracy for cervical cancer staging. Also presently it is easily obtainable, so we recommend using this technique along with clinical examination for staging cervical cancer patients. We also recommend to radiologists and residents of radiology to get experience with this method of staging.

심하복벽동맥 천공지 유리피판에서 술전 MDCT의 유용성 (The Value of Preoperative Multidetector Computed Tomography for Deep Inferior Epigastric Artery Perforator Free Flap)

  • 허찬영;홍기용;윤창진;은석찬;백롱민;민경원
    • Archives of Plastic Surgery
    • /
    • 제36권2호
    • /
    • pp.140-146
    • /
    • 2009
  • Purpose: Autologous breast reconstruction with abdominal tissue is one of the best options after mastectomy. In a free transverse rectus abdominis myocutaneous(TRAM) or deep inferior epigastric artery perforator(DIEP) flap, a preoperative evaluation of the precise location of perforating vessels and vascular run - off systems is required. The objective of this report is to demonstrate the usefulness of multidetector computed tomography(MDCT) in the preoperative planning of patients undergoing breast reconstruction with abdominal flap. Methods: From June 2006 to January 2008, 28 patients underwent MDCT evaluation before breast reconstruction. All subjects were females with an age range of 30 to 55 years. The CT scan was performed using a 64 - slice MDCT scanner(Brilliance 64; Philips Medical Systems, Best, Netherlands). Results: One perforator or two major perforators were marked on image in good relation with a hand - held Doppler examination and intraoperative findings. All vascular run - off systems were cleared before operation. Conclusion: Preoperative evaluation of perforator arteries with MDCT angiography is beneficial in patients undergoing breast reconstruction. This technique provides a noninvasive approach of the vascular anatomy of the entire anterior abdominal wall.

Evaluation of Morphological Changes in Degenerative Cartilage Using 3-D Optical Coherence Tomography

  • Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • 제12권2호
    • /
    • pp.98-102
    • /
    • 2008
  • Optical Coherence Tomography (OCT) is an important noninvasive medical imaging technique that can reveal subsurface structures of biological tissue. OCT has demonstrated a good correlation with histology in sufficient resolution to identify morphological changes in articular cartilage to differentiate normal through progressive stages of degenerative joint disease. Current OCT systems provide individual cross-sectional images that are representative of the tissue directly under the scanning beam, but they may not fully demonstrate the degree of degeneration occurring within a region of a joint surface. For a full understanding of the nature and degree of cartilage degeneration within a joint, multiple OCT images must be obtained and an overall assessment of the joint surmised from multiple individual images. This study presents frequency domain three-dimensional (3-D) OCT imaging of degenerative joint cartilage extracted from bovine knees. The 3-D OCT imaging of articular cartilage enables the assembly of 126 individual, adjacent, rapid scanned OCT images into a full 3-D image representation of the tissue scanned, or these may be viewed in a progression of successive individual two-dimensional (2-D) OCT images arranged in 3-D orientation. A fiber-based frequency domain OCT system that provides cross-sectional images was used to acquire 126 successive adjacent images for a sample volume of $6{\times}3.2{\times}2.5\;mm^3$. The axial resolution was $8\;{\mu}m$ in air. The 3-D OCT was able to demonstrate surface topography and subsurface disruption of articular cartilage consistent with the gross image as well as with histological cross-sections of the specimen. The 3-D OCT volumetric imaging of articular cartilage provides an enhanced appreciation and better understanding of regional degenerative joint disease than may be realized by individual 2-D OCT sectional images.

Demonstration of the Usefulness of Optical Coherence Tomography in Imaging a Mouse Tail Model of Lymphedema

  • Kim, Hui Dong;Kim, Dong Kyu;Chae, Yu-Gyeong;Park, Seok Gyo;Kim, Ghi Chan;Jeong, Ho Joong;Sim, Young-Joo;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.132-137
    • /
    • 2017
  • To investigate the usefulness of optical coherence tomography (OCT) for imaging lymphedema, we directly compared it to other histological methods in a mouse model of lymphedema. We performed detailed imaging of the lymphedema lesion on a mouse tail. We imaged the mouse tail in vivo with OCT and created histopathological samples. We constructed a spectrometer-based OCT system using a fiber-optic Michelson interferometer. The light was directed to 50:50 couplers that split the light into reference and sample arms. Backscattered light from a reference mirror and the sample produced an interference fringe. An OCT image of the lymphedema model revealed an inflammatory reaction of the skin that was accompanied by edema, leading to an increase in the light attenuation in the dermal and subcutaneous layers. Similar to OCT image findings, histological biopsy showed an inflammatory response that involved edema, increased neutrophils in epidermis and subdermis, and lymphatic microvascular dilatation. Furthermore, the lymphedema model showed an increase in thickness of the dermis in both diagnostic studies. In the mouse tail model of lymphedema, OCT imaging showed very similar results to other histological examinations. OCT provides a quick and useful diagnostic imaging technique for lymphedema and is a valuable addition or complement to other noninvasive imaging tools.

동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험 (Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography)

  • 권다영;안예찬
    • 한국광학회지
    • /
    • 제29권3호
    • /
    • pp.99-103
    • /
    • 2018
  • 동적 광단층 탄성영상법은 광 결맞음 단층촬영법을 기반으로 하여 위상차에 의해 조직의 기계적 성질 중 하나인 탄성도를 측정하기 위한 기법이다. 광 결맞음 단층촬영법은 마이켈슨 간섭계를 기반으로 한 비침습적 고해상도 단면 촬영기법이다. 본 논문에서는 광단층 탄성영상법을 생체 조직에 적용하기 전에 실행가능성을 판단하고자 강도를 쉽게 구분할 수 있는 지우개, 스펀지, 샤프심으로 샘플을 제작하여 실험을 진행하였다. 샘플에 사인파의 일정한 진동자극을 가하기 위해 압전액추에이터를 샘플의 아래쪽에 위치시켰으며 위쪽에서 광 결맞음 단층촬영법으로 스캔하였다. 깊이마다 횡방향에 대한 변형속도를 힐버트 변환하여 포락선을 검출한 후 포락선의 높낮이를 색깔로 표현하여 이미지 상에서 샘플 내의 상대적인 강도를 비교할 수 있었다. 또한, 샘플단과 참조단 사이의 간섭을 이용하는 것보다 샘플단 내의 자기간섭을 이용할 경우 변형속도 계산에 있어 장점이 있음을 제시하였다.

Frequency analysis of the tonic vibration reflex of the hand flexor muscles

  • 박희석
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1994년도 춘계학술대회논문집
    • /
    • pp.49-51
    • /
    • 1994
  • The aims of this study were first to determine the influence of vibration displacement amplitude $(200{\mu}m, 300{\mu}m peak-to-peak)$ at selected frequencies (40-200Hz) on a commonly observed but often undesired motor response elicited bylocal vibratory stimulation, the Tonic Vibration Reflex (TVR). Second, to determine the degree of synchronization of motor unit (MU) activity with vibratory stimuli. Vibration was applied to the distal tendons of the hand flexor muscles. Changes in root- mean-square electromyographic (EMG) activity of the finger and wrist flexor muscles were analyzed both as a function of their initial contraction level (0%, 10%, 20% of the maximal voluntarycontraction: MVC) and as a function of the vibration parameters. The results indicate that the TVR increased with the initial muscle contraction up to 10% MVC: The TVR increased with vibration frequency up to 100-150 Hz and decreases beyond; A significant increase of the TVR with vibration displacement amplitude was observed only for the wrist flexor muscle; MU synchronization at vibration frequency (VF) was found more often in the low frequency range $(f{\leq}100 Hz)$ and tended todecrease beyond; In the high frequency range $(f{\geq}120 Hz)$, MU activity at subharmonic frequency was predominant; The "cut-off" frequency of the synchronization with VF was neither affected by the vibration displacement amplitude nor initial muscle contraction level. The surface EMG turned out to be a useful means to analyze MU synchronization since it is noninvasive, and it can be easily used for analysis of different muscle contraction levels, while single MU technique might have some difficulties at high muscle contraction levels. Furthermore, these results indicate that high frequencyvibration (f>150 Hz) tends to induce less muscle/tendon stress and MU synchronization. Such remarks are of importance for the design of hand-held vibrating tools.ing tools.

  • PDF

Confirmation of Male Specific Fetal Free RNA in Maternal Plasma and Comparison of Accuracy on the Sex Determination using Real-time PCR Method in Korean Native Cattle

  • Lee, Sang-Ho;Park, Chul-Ho;Park, Jun-Tae;Park, Sang-Guk;Lee, Jin-A;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-Ho
    • 한국수정란이식학회지
    • /
    • 제28권4호
    • /
    • pp.343-348
    • /
    • 2013
  • Cell-free fetal RNA has been highlighted as useful tools for the fetal sex determination or other genetic inherent disorder. However, there is no knowledge about the sex determination using cell free fetal RNA in bovine field. Thus, the present study aimed to evaluate the presence of transcripts of DDX3Y, USP9Y and ZRSR2Y genes in maternal plasma of pregnant cows to determine the sex of the fetus using real-time quantitative polymerase chain reaction assay, and verify its accuracy, sensitivity and specificity compared with the molecular testing and the calf sex at birth. Transcripts of USP9Y and DDX3Y genes were expressed in the all plasma of males and females both the control group and the experimental group. However, ZRSR2Y gene was matched up with the molecular testing and the true sex in control group and has an overall accuracy of 82.6%, a sensitivity of 75%, and a specificity of 100% in experimental group. Therefore, these results indicated that real time PCR technique, as a noninvasive and cost-efficient method, is possible to determination fetal sex in the bovine species using circulating cell free RNA in maternal plasma and especially ZRSR2Y gene could be a good candidate for the RNA based sex determination work.