• Title/Summary/Keyword: Noninvasive diagnosis

Search Result 166, Processing Time 0.024 seconds

Diagnostic Efficacy of PET in Soft Tissue Tumors: Comparative Study with Conventional Methods (연부 조직 종양에서 PET의 유용성: 기존의 진단법과의 비교 연구)

  • Seo, Sung-Wook;Park, Sang-Min;Cho, Hwan-Seong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.32-39
    • /
    • 2005
  • Introduction: Currently, F-18 fluorodeoxyglucose positron emission tomography scans (FDG-PET) has been investigated in soft tissue tumor especially for tumor detection and noninvasive grading. However, the validity and the efficacy of FDG-PET are still unclear in clinical evaluation. The purpose of this study is to determine the efficacy of FDG-PET in compared to conventional diagnostic imaging studies currently used in the soft tissue tumor. Methods: Between March 2001 and March 2002, 29 patients (sixteen males, thirteen females, mean age, 47 years; a range from 4 to 73) diagnosed with soft tissue tumor were evaluated by both conventional diagnostic imaging and FDG-PET. Valid reference test of the local lesion was the histopathologic diagnosis, which was measured in all patients. The suspecting metastasis in the imaging studies was validated by pathology or follow up imaging for at least 6 months. Each imaging diagnosis was made independently. The accuracy of each diagnostic method was evaluated. The incremental cost accuracy ratio was determined in each diagnostic method. Results: For detection of local lesion, sensitivity, specificity, and accuracy for MRI and FDGPET scans were 91%, 57%, 83% and 95%, 43%, 83% respectively. For detection of distant lesion, sensitivity, specificity, accuracy for conventional diagnostic methods and FDG-PET scans were 77%, 89%, 87% and 92%, 94%, 93% respectively. The incremental cost accuracy ratio (ICAR) of FDG-PET for detection of distant lesion was 145,000won/%. According to ICAR for each tumor grade, PET strategy is most cost-effective at high grade tumors. Conclusions: For detection of local lesion such as recurrence or remnant tumor, FDG-PET scan was not more accurate than MRI. However, It was more accurate for detection of metastatic lesion than conventional methods. For detection of high grade tumor, PET was most costeffective than for detection of lower grade tumor.

  • PDF

Diagnosis of Functional Nasolacrimal Duct Obstruction Using Dacryoscintigraphy (누비공신티그라피를 이용한 기능적 누도폐쇄의 진단)

  • Lim, Hyun-Wook;Sohn, Hyung-Sun;Kim, Euy-Neyng;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.508-515
    • /
    • 2000
  • Purpose: To evaluate the value of dacryoscintigraphy in the assessment of patients with a clinical diagnosis of functional nasolacrimal duct obstruction. Materials and Methods: Dacryoscintigraphy was performed in symptomatic 35 lacrimal drainage systems in 18 patients (age range: $37{\sim}76$, 8 males, 10 females) that were patent on syringing. Results: Abnormalities were detected with dacryoscintigraphy in 75.8% of systems. The positive scintigrams were subdivided into those demonstrating prelacrimal sac delay (31.8%), delay at the lacrimal sac/junction (40.9%), or delay within the duct (21%). Conclusion: Dacryoscintigraphy is noninvasive useful technique in the assessment of the functional nasolacrimal duct obstruction and very sensitive at detecting abnormalities in patients with lid laxity caused by senile change and facial nerve palsy.

  • PDF

Ultrasonographic and radiographic study on experimental cystitis in rabbit (실험적 방광염 유발 토끼에서의 초음파 및 방사선학적 연구)

  • Sung, Jai-ki;Chang, Dong-woo;Yoon, Jung-hee
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.4
    • /
    • pp.973-990
    • /
    • 1996
  • To investigate diagnostic imaging of cystitis and to apply it to the small animal practice, ultrasonogram of urinary bladder with moderate distension(4ml/kg) and with complete distension(9ml/kg) to evaluate the irregularity and thickness of bladder, radiography and histopathological examination were performed after experimental cystitis induction. On double contrast cystography, mucosal membrane of the urinary bladder was smooth and thickening urinary bladder wall was not found before cystitis induction. At 3rd day post induction(PI), mucosal irregularity was noted at the cranioventral region of the urinary bladder. Thickening of the urinary bladder wall and filling defect was observed as well. Cystographic findings of 7, 10, 15, 21 day PI were similar to that of 3rd day PI. On ultrasonographic findings of the mural thickness in induction group, it was ascertain that the mural thickness with moderate distention was more thickened than with complete distention at transverse scan. Ultrasonographic findings at longitudinal scan were similar to those of transverse scan. On ultrasonographic findings of mucosal irregularity in induction group, from PI to 7 day PI, mucosal irregularity with moderate distention was more irregular than mucosal irregularity with complete distention. At 10 day PI, there was similarity between moderate distention and complete distention. On histopathologic examination of a section of urinary bladder taken 3 day PI, the mucosal and submucosa were infiltrated by a mixture of thick inflammatory exudate which was composed of neutrophil, plasma protein, bacterial colony and necrotic cells. Congestion, hemorrhage and edema were also observed in the submucosa. At 7th day PI, the mucosal change was similar to that of 3rd day PI, but neovascularization and fibroplasia were observed in the submucosa. At 15th and 21th day PI, mild hyperplasia of mucosal epithelium was observed in the mucosa. Deposition of collagen, neovascularization and severe diffuse infiltration of lymphocyte were observed. These results suggest that ultrasonographic examination with moderate distention is considered to be a more simple, rapid, noninvasive, sensitive and useful diagnostic method than other diagnostic methods for the diagnosis of the cystitis and the differential diagnosis of urinary tract infection.

  • PDF

Acoustic Analysis and Auditory-Perceptual Assessment for Diagnosis of Functional Dysphonia (기능성 음성장애의 진단을 위한 음향학적, 청지각적 평가)

  • Kim, Geun-Hyo;Lee, Yeon-Yoo;Bae, In-Ho;Lee, Jae-Seok;Lee, Chang-Yoon;Park, Hee-June;Lee, Byung-Joo;Kwon, Soon-Bok
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.212-222
    • /
    • 2018
  • Background and Objectives : The purpose of this study was to compare the measured values of acoustic and auditory perceptual assessments between normal and functional dysphonia (FD) groups. Materials and Methods : 102 subjects with FD and 59 normal voice groups were participated in this study. Mid-vowel portion of the sustained vowel /a/ and two sentences of 'Sanchaek' were edited, concatenated, and analyzed by Praat script. And then auditory-perceptual (AP) rating was completed by three listeners. Results : The FD group showed higher acoustic voice quality index version 2.02 and version 3.01 (AVQIv2 and AVQIv3), slope, Hammarberg index (HAM), grade (G) and overall severity (OS), values than normal group. Additionally, smoothed cepstral peak prominence in Praat (PraatCPPS), tilt, low-to high spectral band energies (L/H ratio), long-term average spectrum (LTAS) in FD group were lower than normal voice group. And the correlation among measured values ranged from -0.250 to 0.960. In ROC curve analysis, cutoff values of AVQIv2, AVQIv3, PraatCPPS, slope, tilt, L/H ratio, HAM, and LTAS were 3.270, 2.013, 13.838, -22.286, -9.754, 369.043, 27.912, and 34.523, respectively, and the AUC of each analysis was over .890 in AVQIv2, AVQIv3, and PraatCPPS, over 0.731 in HAM, tilt, and slope, over 0.605 in LTAS and L/H ratio. Conclusions : In conclusion, AVQI and CPPS showed the highest predictive power for distinguishing between normal and FD groups. Acoustic analyses and AP rating as noninvasive examination can reinforce the screening capability of FD and help to establish efficient diagnosis and treatment process plan for FD.

Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System (관상동맥 질환 판독과 자료 체계와 CT 혈관조영술에서의 경계성 관상동맥 병변)

  • Hyewon Park;Yu-Whan Oh;Ki Yeol Lee;Hwan Seok Yong;Cherry Kim;Sung Ho Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.297-307
    • /
    • 2024
  • Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.

Plasma D-dimer Determination in the Diagnosis of Pulmonary Embolism (폐색전증의 진단에 있어 혈청 D-dimer 측정의 진단적 가치)

  • Lim, Chae-Man;Kim, Hong-Kyu;Choi, Kang-Hyun;Lee, Sand-Do;Koh, Youn-Suck;Kim, Woo-Sung;Jang, Jae-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.69-74
    • /
    • 1996
  • Background: The diagnosis of pulmonary embolism (PE) based on clinical findings is often elusive and therefore requires confirmative diagnostic method. Pulmonary angiography, though the gold standard for the diagnosis of pulmonary embolism, is an invasive method and requires trained personnel and special equipment. Lung V/Q scan, on the other hand, is a noninvasive method but the diagnostic specificity and sensitivity arc not satisfactory in case that the results are either intermediate or low probability scan. Plasma D-dimer is generated when a thrombus is fibrinolysed by plasmin and is known to be increased in various thrombotic disorders. The aim of this study was to investigate the value of the determination of plasma D-dimer level in the diagnosis of pulmonary embolism. Methods: Pulmonary angiography was performed in 17 patients who were clinically suspected to have pulmonary embolism. 9 patients(PE, $56{\pm}13.4$ yrs, M:F=8:1) were diagnosed to have pulmonary embolism by pulmonary angiography. The control group were the 8 patients with negative pulmonary angiography and 13 orthopedic patients with no evidence of pulmonary embolism on scintigraphic and impedance plethysmographic studies(n=21) (non-PE, $54.5{\pm}11.1$ yrs, M:F=11:10). Plasma D-dimer was measured by latex agglutination method in study subjects and the results were analyzed according to the presence or absence of pulmonary embolism. Results: 1) The increased level of plasma D-dimer was more frequently observed in the patients with pulmonary embolism than in the controls(>0.5 mg/L, 8 in PE, 10 in non-PE; <0.5 mg/L, 1 in PE, 11 in non-PE, p=0.049). 2) The diagnostic value of plasma D-dimer level higher than 0.5 mg/L were as follows: sensitivity 88.9%(8/9), specificity 52.4%(11/21), positive predictive value 44.4%(8/18), and negative predictive value 91.7%(11/12). Conclusion: Plasma D-dimer determination showed high sensitivity and negative predictive value in the diagnosis of pulmonary embolism and is therefore thought to be useful in excluding the possibility of pulmonary embolism.

  • PDF

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF

Can the C-14 Urea Breath Test Reflect the Extent and Degree of Ongoing Helicobacter pylori Infection? (C-14 요소호기검사의 정량치가 Helicobacter pylori 감염 정도를 반영할 수 있을까?)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok;Lee, Soo-Teik;Jeong, Myoung-Ja
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.61-68
    • /
    • 2001
  • Purpose: The C-14 urea breath test (C-14 UBT) is the most specific noninvasive method to detect Helicobacter (H) pylori infection. We investigated if the C-14 UBT can reflect the presence and degree of H. pylori detected by gastroduodenoscopic biopsies (GBx). Materials and methods: One hundred fifty patients (M:F=83:67, age $48.6{\pm}11.2$ yrs) underwent C-14 UBT, rapid urease test (CLO test) and GBx on the same day. For the C-14 UBT, a single breath sample was collected at 10 minutes after ingestion of C-14 urea (137 KBq) capsule and counting was done in a liquid scintillation counter for 1 minute, and the results were classified as positive (${\geq}200dpm$), Intermediate ($50{\sim}199dpm$) or negative (<50 dpm). The results of CLO tests were classified as positive or negative according to color change. The results of GBx on giemsa stain were graded 0 (normal) to 4 (diffuse) according to the distribution of H. pylori by the Wyatt method. We compared C-14 UBT results with GBx grade as a gold standard. Results: In the assessment of the presence of H. pylori infection, the C-14 UBT global performance yielded sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92.5%, 88.4%, 97.1%, 88.4% and 91.3%, respectively. However, the CLO test had sensitivity, specificity, PPV, NPV and accuracy of 83.2%, 81.4%, 91.8%, 81.4% and 82.7%, respectively. The quantitative values of the C-14 UBT were $45{\pm}27$ dpm in grade 0, $707{\pm}584dpm$ in grade 1, $1558{\pm}584dpm$ in grade 2, $1851{\pm}604dpm$ in grade 3, and $2719{\pm}892dpm$ in grade 4. A significant correlation (r=0.848, p<0.01) was found between C-14 UBT and the grade of distribution of H. pylori infection on GBx with giemsa stain. Conclusion: We conclude that the C-14 UBT is a highly accurate, simple and noninvasive method for the diagnosis of ongoing H. pylori infection and reflects the degree of bacterial distribution.

  • PDF

The Usefulness of MRCP in the Evaluation of Pancreaticobiliary Diseases in Children (소아에서 담췌관 질환에 대한 자기공명 담췌관조영술의 진단적 유용성)

  • Uhm, Ji Hyun;Lee, Seung Yeon;Chung, Ki Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1381-1388
    • /
    • 2002
  • Purpose : Magnetic resonance cholangiopancreatography(MRCP) is a noninvasive method for imaging the pancreaticobiliary tree. The aim of this study was to evalute the usefulness of MRCP for the diagnosis of pancreaticobiliary diseases in children. Methods : From October 1996 to May 2001, 67 patients with obstructive jaundice and three patients with chronic recurrent pancreatitis were evaluated with abdominal ultrasonography and MRCP. The final diagnosis was based on the operative and pathologic findings with biopsy specimen including clinical and laboratory findings. Results : A total of 70 patients, consisting of 31 males and 39 females, with a mean age of $2.6{\pm}3.3$ years were studied. The final diagnosis was biliary atresia in 25, neonatal cholestasis in 18, choledochal cyst without anomalous pancreatobiliary duct union(APBDU) in nine, choledochal cyst with APBDU in seven, cholestatic hepatitis in five, chronic recurrent pancreatitis in three, sclerosing cholangitis in two, and secondary biliary cirrhosis in one case. The overall diagnostic accuracy of abdominal ultrasonography was 75.7% and that of MRCP was 97.1%. The sensitivity and specificity of MRCP were 100% and 98% for biliary atresia, 87.5% and 100% for choledochal cyst with APBDU, 100% and 100% for choledochal cyst without APBDU, sclerosing cholangitis and chronic recurrent pancreatitis, respectively. Conclusion : MRCP is a fast, non-invasive and reliable method for diagnosing pancreaticobiliary diseases in children and will be the standard diagnostic procedure in the future.

Clinical Significance of Segmental Parenchymal Excretion Delay on Tc-99m DISIDA Hepatobiliary Scan (Tc-99m DISIDA 간담도 신티그라피에서 간 실질의 분절형 배설지연의 임상적 의의)

  • Kang, Do-Young;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Sung-Koo;Kim, Myung-Hwan;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1998
  • Purpose: Segmental parenchymal excretion delay on Tc-99m DISIDA scan is caused by intrahepatic bile duct obstruction. However, the diagnostic value for intrahepatic bile duct obstruction is unknown. We conducted this study to assess the positive predictive value of segmental excretion delay for the diagnosis of intrahepatic bile duct obstruction, and additional benefit over other noninvasive radiologic studies. Materials and Methods: The study population consisted of 43 patients (48 scans) who showed segmental parenchymal excretion delay on Tc-99m DISIDA scan. The results of abdominal CT or ultrasonography, which was done within 1 month of Tc-99m DISIDA scan, were compared with scintigraphic findings. Results: The etiology of segmental parenchymal excretion delay was determined by ERC or PTC in 31 scans, and follow-up studies in 13 scans. No causes were identified in 4 scans. The positive predictive value of segmental parenchymal excretion delay for intrahepatic bile ductobstruction was 92% (44/48). On the other hand, 13% (5/38) of CT and 28% (5/18) of ultrasonography were normal. In 18% (7138) of CT and 17% (3/18) of ultrasonography, only intraheipatic bile duct dilatation was noted without any diagnostic findings of intrahepatic bile duct obstruction. Conclusion: Segmental parenchymal excretion delay on Tc-99m DISIDA scan had a high positive predictive value for the diagnosis of intrahepatic bile duct obstruction. Tc-99m DISIDA scan may be useful for the diagnosis of intrahepatic bile duct obstruction, especially in patients with nondiagnostic CT or ultrasonography. The diagnostic usefulness need to be confirmed by further prospective studies.

  • PDF