• Title/Summary/Keyword: Non-thermal plasma reactor

Search Result 60, Processing Time 0.033 seconds

Study of toluene decomposition using nonthermal plasma and catalyst (저온플라즈마와 촉매를 이용한 톨루엔 분해 연구)

  • Lim, Yun Hui;Lee, Ju-Yeol;Shin, Jae-Ran;Choi, Jin-Sik;Park, Byung Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.541-548
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $C_7H_8$ using non-thermal plasma and metal-supported catalyst. Adsorption-desorption characteristics of toluene was performed using 4A type (Zeolite) filled in a concentration reactor. Through this test, it was found that the concentration reactor has 0.020 g/g of adsorption capacity (at ambient temperature and pressure) and 3,600 ppm of desorption property at $150^{\circ}C$ (with in 20 min). In case of developed catalyst, toluene decomposition rate of Pd-AO (Pd coated catalyst) was better than Pd/Cu-AO and Pd/Ag-AO (Pd/Ag composite metal catalyst). Developed non-thermal plasma system was obtained flame amplification effect using injection process of desorbed tolune, and 98% of removal efficiency.

Effect of Non-thermal plasma Reactor construction by $CF_4$ decomposition ($CF_4$ 분해에 미치는 비열플라즈마 반응기 구조의 영향)

  • Kim, Sun-Ho;Park, Jae-Yun;Ha, Hyun-Jin;Hwang, Bo-Guk;Kim, Kwang-Soo;Rim, Geun-Hie
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.912-916
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for a simulated two plasma reactors which are metal particle reactor and spiral wire reactor as function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25[%] over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80[%] at AC 24[kV]. The $CF_4$ decomposition rate used $Ar-N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $Ar-N_2$ base as were similar, but in case of air base they were different.

  • PDF

A Study on the Flow Characteristic of Non-Thermal Plasma Reactor for Demonstration (실증실험용 저온 플라즈마 반응기의 유동특성에 관한 연구)

  • Kim, Y.S.;Choi, S.H.;Kim, J.I.;Kim, T.H.;Yoo, J.S.;Paek, M.S.;Jang, G.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.508-513
    • /
    • 2000
  • HANJUNG has developed demonstration plant treating combustion flue gas such as dioxide($SO_2$) and nitrogen oxides(NOx). Before operating this system, we tested the inner airflow characteristic of demonstration plant in the front of plasma reactor field 1 and field 2. The experimental results of $25,000Nm^3/hr$ airflow are compared with the computational results using FLUENT code. It is found that the velocity distribution trends are matched the experimental results with the calculation results. To improve the eccentric airflow in the inlet hood, it is necessary to install the vertical guide vane as well as the horizontal guide vane.

  • PDF

Effect of Mixed Gases on Decomposition Characteristic of CF4 by Non-Thermal Plasma (비열플라즈마를 이용한 CF4 분해에 미치는 혼합가스의 영향)

  • 박재윤;정장근;김종석;임근희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.543-550
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for two simulated plasma reactors which are metal particle reactor and spiral wire reactors as a function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25% over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80% at AC 24kV. The $CF_4$ decomposition rate used Ar-$N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $N_2Ar$ base as were similar, but in case of air base they were different.

Decomposition of Ethylene using a Hybrid Catalyst-packed Bed Plasma Reactor System (플라즈마 충진 촉매 시스템을 이용한 에틸렌 저감 연구)

  • Lee, Sang Baek;Jo, Jin-Oh;Jang, Dong Lyong;Mok, Young Sun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.577-585
    • /
    • 2014
  • A series of experiments using atmospheric-pressure non-thermal plasma coupled with transition metal catalysts were performed to remove ethylene from agricultural storage facilities. The non-thermal plasma was created by dielectric barrier discharge, which was in direct contact with the catalyst pellets. The transition metals such as Ag and $V_2O_5$ were supported on ${\gamma}-Al_2O_3$. The effect of catalyst type, specific input energy (SIE) and oxygen content on the removal of ethylene was examined to understand the behavior of the hybrid plasma-catalytic reactor system. With the other parameters kept constant, the plasma-catalytic activity for the removal of ethylene was in order of $V_2O_5/{\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ from high to low. Interestingly, the rate of plasma-catalytic ozone generation was in order of $V_2O_5/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$, implying that the catalyst activation mechanisms by plasma are different for different catalysts. The results obtained by varying the oxygen content indicated that nitrogen-derived reactive species dominated the removal of ethylene under oxygen-lean condition, while ozone and oxygen atoms were mainly involved in the removal under oxygen-rich condition. When the plasma was coupled with $V_2O_5/{\gamma}-Al_2O_3$, nearly complete removal of ethylene was achieved at oxygen contents higher than 5% by volume (inlet ethylene: 250 ppm; gas flow rate: $1.0Lmin^{-1}$; SIE: ${\sim}355JL^{-1}$).

A study on non-thermal plasma reactor for generation of negative ions (음이온 발생을 위한 저온 플라즈마 반응기 개발에 관한 연구)

  • Yu, Guang-Xun;Chae, Jae-Ou;Kim, Woo-Hyung;Wei, Wei;Wang, Hui
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2344-2347
    • /
    • 2007
  • To generate negative ion, a small dielectric barrier discharge (DBD) plasma reactor was used in this study and operated by high AC voltage. With increasing of voltage, we can get more negative ions. However unfortunately, if the input voltage is too high, it will also cause formation of ozone which is very harmful to human being health. So the work of finding out the best condition of Voltage and frequency was carried out firstly. After several times of measurement, operating at 20 kHz frequency is the best condition generating high ion concentration without ozone. For the purpose of finding out the best reactor structure, two types of surface dielectric barrier discharge (DBD) reactors were examined to produce negative oxygen ions at the conditions of 20 kHz frequency. The results indicated that the surface DBD reactor with several small tips showed better characteristics for generation of negative oxygen ions at the same condition.

  • PDF

A Study on NOx Removal by Using Plasma Discharge (플라즈마 방전을 이용한 NOx 제거에 관한 연구)

  • 김동욱;정영식
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.78-83
    • /
    • 1999
  • This work is the experimental study for NO and NOx removal by utilizing non-thermal plasma. To apply to moving pollution source such as diesel automobile, we suggested the metal packed-helical wire reactor(MPHW) and measured properties of MPHW by varying the peak voltage, frequency, NOx concentration and flow rate for simulated NOx gas balanced with $N_2$. And then we compared these results with the results of cylinder-wire(CW) which was one of popularly used reactor in nonthermal plasma applications. The results of MPHW show fairly good NO and NOx removal rate compare with CW around above 20%. However. the power consumption of MPHW is larger than that of CW as much as around 2.5Watt in all range.

  • PDF

The effect of vibration of the water surface for hydrogen gas generation by plasma electrical discharge (비열플라즈마에 의한 수소가스발생에 미치는 수표면 진통효과)

  • Kim, Jong-Seog;Park, Jae-Yoon;Jung, Jang-Gun;Kim, Tae-Yong;Lee, Jae-Dong;Koh, Hee-Seog;Lee, Hyun-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.115-119
    • /
    • 2004
  • This paper is investigated about the effect of vibration of the water surface for hydrogen gas generation by non-thermal plasma. The vibration of the water surface is more powerful with increasing applied voltage. In this experimental reactor which is made of multi-needle and plate, the maximum acquired hydrogen production rate is about 6.8[ml/sec]. Although the generation of hydrogen gas is increased with elevating time, it is saturated after specific time due to the volume of reactor and the saturation of taylor cone.

  • PDF

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

Effect of Dielectrics on NOx Removal of Metal Particle-AI2O3 Barrier Reactor (금속파티클-AI2O3Barrier 반응기의 NOx 제거에 미치는 유전체 영향)

  • 박재윤;김종석;고희석;김형만;배명환
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.3
    • /
    • pp.247-252
    • /
    • 2003
  • In this paper, we made four types of metal particle $Al_2$O$_3$ barrier reactors with and without dielectric of BaTiO$_3$ between metal particle and $Al_2$O$_3$ barrier to investigate NOx removal characteristic and the effect of dielectric on Nox removal. And Nox removal rate is measured when sludge pellets are put at down stream of plasma reactor. Nox removal rate in the reactor with $Al_2$O$_3$ barrier is much better than that in the reactor without $Al_2$O$_3$ barrier, Nox removal rate is not so good in metal particle-Al$_2$O$_3$ barrier reactor with BaTiO$_3$ between metal particle and $Al_2$O$_3$ barrier, however, Nox removal rate is about 40% in metal particle-Al$_2$O$_3$ barrier reactor with TiO$_2$. The most of NO is conversed to NO$_2$ in these kind of reactor. When sludge pellets are put at down stream of plasma reactor, Nox removal rate is greatly improved up to 90%. It indicates that sludge pellets have great effect on the NO$_2$ removal and the improvement of Nox removal rate, however, dielectric materials between metal particle and $Al_2$O$_3$ barrier have not effect. Organic materials included in sludge may react with NO$_2$ and ozone so that Nox removal rate is greatly improved.