• Title/Summary/Keyword: Non-thermal Atmospheric Pressure Plasma

Search Result 41, Processing Time 0.035 seconds

Applications of Non-Thermal Atmospheric Pressure Plasma in Dentistry (상온 대기압 플라즈마의 치의학적 응용)

  • Uhm, Soo-Hyuk;Kwon, Jae-Sung;Lee, Eun-Jung;Lee, Jung-Hwan;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.783-794
    • /
    • 2014
  • Since the introduction of non-thermal atmospheric pressure plasma in the field of the dentistry, numerous applications have been investigated. Especially with its advantages over existing vacuum plasma in terms of portability, low cost, and non-thermal damage, it can be directly applied in the oral cavity, giving number of potentials for dental application. First, possible application of non-thermal atmospheric pressure plasma in the field of dentistry is relation to dental caries and periodontal diseases. Teeth and alveolar bones are one of the strongest bony structures in our body, but it cannot be regenerated when they are damaged by dental caries or periodontal disease. Hence many studies to prevent such diseases have been carried out, though no perfect solution has been found yet. With recent studies of modifying surfaces through non-thermal atmospheric pressure application that can prevent attachment of bacteria, or studies on bactericidal effects of non-thermal atmospheric pressure plasma can be applied here to prevent oral pathogen and 'biofilm' attachment to the surface of teeth or directly eliminate the dental caries/periodontal disease causing germs. Secondly, non-thermal atmospheric pressure application will be useful on the surface of dental implant. It is well known that the success of dental implant surgery depends on the process known as 'osseointegration' that result from osteoblast attachment, proliferation and differentiation. As the application of non-thermal atmospheric pressure plasma on the surface of dental implant just before its introduction by the chair-side of dental surgery. Despite its long history, the generation of non-thermal atmospheric pressure plasma has been greatly increased with its application in dentistry.

Non-Thermal Atmospheric-Pressure Plasma Possible Application in Wound Healing

  • Haertel, Beate;von Woedtke, Thomas;Weltmann, Klaus-Dieter;Lindequist, Ulrike
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.477-490
    • /
    • 2014
  • Non-thermal atmospheric-pressure plasma, also named cold plasma, is defined as a partly ionized gas. Therefore, it cannot be equated with plasma from blood; it is not biological in nature. Non-thermal atmospheric-pressure plasma is a new innovative approach in medicine not only for the treatment of wounds, but with a wide-range of other applications, as e.g. topical treatment of other skin diseases with microbial involvement or treatment of cancer diseases. This review emphasizes plasma effects on wound healing. Non-thermal atmospheric-pressure plasma can support wound healing by its antiseptic effects, by stimulation of proliferation and migration of wound relating skin cells, by activation or inhibition of integrin receptors on the cell surface or by its pro-angiogenic effect. We summarize the effects of plasma on eukaryotic cells, especially on keratinocytes in terms of viability, proliferation, DNA, adhesion molecules and angiogenesis together with the role of reactive oxygen species and other components of plasma. The outcome of first clinical trials regarding wound healing is pointed out.

The Killing Effect of Candida albicans on Hairless Mouse-2 Mouse Tissues by Non-Thermal Atmospheric Pressure Plasma (저온 상압플라즈마에 의한 Hairless Mouse-2 마우스 조직의 Candida albicans 사멸 효과)

  • Park, Sang-Rye;Kim, Gyoo-Cheon
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • The purpose of this study was to investigate the killing effect of Candida albicans on hairless mouse-2 (HRM-2) mouse tissues. We tested the effectiveness of a non-thermal atmospheric pressure plasma in killing C. albicans strains. The viability of C. albicans was determined by counting the colony forming units (CFU), after non-thermal atmospheric pressure plasma treatment. When non-thermal atmospheric pressure plasma was repeatedly treated on mouse skin which inoculated with C. albicans. The C. albicans cells were planted on skin tissue, and then the infected mouse tissue was exposed to non-thermal atmospheric pressure plasma for 0 sec, 60 sec, 180 sec and 300 sec. The death rate of C. albicans was increased in dependent with treatment times. The three times of non-thermal atmospheric pressure plasma at the interval of 10 minutes significantly showed the 6 log CFU/ml reduction of death rate on HRM-2 mouse tissues. Thus, non-thermal atmospheric pressure plasma could be used for the disinfection of C. albicans on oral surface.

Measurement of Hydroxyl Radical Density at Bio-Solutions Generated from the Atmospheric Pressure Non-Thermal Plasma Jet

  • Kim, Yong Hee;Hong, Young June;Uhm, Han Sub;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.494-494
    • /
    • 2013
  • Atmospheric pressure non-thermal plasma of the needle-typed interaction with aqueous solutions has received increasing attention for their biomedical applications [1]. In this context, surface discharges at bio-solutions were investigated experimentally. We have generated the non-thermal plasma jet bombarding the bio-solution surface by using an Ar gas flow and investigated the emission lines by OES (optical emission spectroscopy) [2]. Moreover, The non-thermal plasma interaction with bio-solutions has received increasing attention for their biomedical applications. So we researched, the OH radical density of various biological solutions in the surface by non-thermal plasma were investigated by Ar gases. The OH radical density of DI water; deionized water, DMEM Dulbecco's modified eagle medium, and PBS; 1x phosphate buffered saline by non-thermal plasma jet. It is noted that the OH radical density of DI water and DMEM are measured to be about $4.33{\times}1016cm-3$ and $2.18{\times}1016cm-3$, respectively, under Ar gas flow 250 sccm (standard cubic centimeter per minute) in this experiment. The OH radical density of buffer solution such as PBS has also been investigated and measured to be value of about $2.18{\times}1016cm-3$ by the ultraviolet optical absorption spectroscopy.

  • PDF

Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments

  • Sung, Su-Jin;Huh, Jung-Bo;Yun, Mi-Jung;Chang, Brian Myung W.;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.2-8
    • /
    • 2013
  • PURPOSE. Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. MATERIALS AND METHODS. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (${\alpha}$=0.05). RESULTS. The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. CONCLUSION. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.

The Development of Non-thermal Micro Plasma Source Under Atmospheric Pressure by Means of Submicrosecond Pulse Voltage Waveforms (서브마이크로 펄스 전압파형을 이용한 대기압 저온 마이크로 플라즈마 소스 개발)

  • Choi, Joon-Young;Lee, Ho-Jun;Kim, Dong-Hyun;Lee, Hae-June;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1802-1806
    • /
    • 2007
  • Nowadays, many configurations and applications of small atmospheric plasma source have been investigated with growing interest, as it provides the bacteria inactivation, the surface modification and removal of unwanted small regions, and so on. In this paper, the non-thermal micro plasma source under atmospheric pressure by means of submicrosecond pulse voltage waveforms is suggested. Plasma operates in helium is appears as a small (sub-mm) glow at the tip of a plasma gun. Electrical measurements show that the plasma source operates at low voltage (about 500V) and the power consumption is about 1W at 25kHz. Moreover, the emission spectrum shows the relatively higher emission intensity of oxygen particles than those of helium and nitrogen.

Treatment of Refractory Melasma with Microwave-generated, Atmospheric-pressure, Non-thermal Nitrogen Plasma

  • Kim, Hyun-Jo;Kim, Heesu;Kim, Young Koo;Cho, Sung Bin
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.74-79
    • /
    • 2019
  • Periorbital melasma is often refractory to treatment and highly associated with rebound hyperpigmentation or mottled hypopigmentation after laser treatment in Asian patients. In this report, we describe 2 patients with cluster-1 periorbital melasma and 1 patient with cluster-2 periorbital melasma who experienced remarkable clinical improvements after microwave-generated, atmospheric-pressure, non-thermal nitrogen plasma treatments. All patients exhibited limited clinical responses after combination treatments with topical bleaching agents, systemic oral tranexamic acid, and low-fluenced Q-switched neodymium (Nd):yttrium-aluminum-garnet (YAG) lasers. Low-energy nitrogen plasma treatment at 0.75 J elicited remarkable clinical improvement in the periorbital melasma lesions without post-laser therapy rebound hyperpigmentation and mottled hypopigmentation. We deemed that a single pass of nitrogen plasma treatment at 0.75 J induces mild microscopic thermal tissue coagulation and modification within the epidermis while preserving the integrity of the basement membrane in patients with periorbital melasma. Accordingly, nitrogen plasma-induced dermal tissue regeneration could play a role in the treatment of melasma lesions.

ELECTRON TEMPERATURE ESTIMATION OF NON-THERMAL ATMOSPHERIC-PRESSURE NEON AND OXYGEN ADMIXTURE PLASMA JET BY CONVECTIVE WAVE PACKET MODEL

  • SORNSAKDANUPHAP, Jirapong;SUANPOOT, Pradoong;Hong, Young June;Ghimire, Bhagirath;CHO, Guangsup;CHOI, EunHa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.207-207
    • /
    • 2016
  • plasma group velocities of neon with oxygen admixture (ug) are obtained by intensified charge coupled device (ICCD) camera images at fixed gate width time of 5 ns. The propagation velocities outside interelectrode region are in the order of 104 m/s.The plasma ambipolar diffusion velocities are calculated to be in the order of 102 m/s. Plasma jet is generated by all fixed sinusoidal power supply, total gas flow and repetition frequency at 3 kV, 800 sccm and 40 kHz, respectively. The amount of oxygen admixture is varied from 0 to 2.75 %. By employing one dimensional convective wave packet model, the electron temperatures in non-thermal atmospheric-pressure plasma jet are estimated to be in a range from 1.65 to 1.95 eV.

  • PDF

ELECTRON TEMPERATURE ESTIMATION OF NON-THERMAL ATMOSPHERIC-PRESSURE NEON AND ARGON PLASMA JET BY CONVECTIVE WAVE PACKET MODEL

  • SORNSAKDANUPHAP, Jirapong;SUANPOOT, Pradoong;Hong, Young June;Ghimire, Bhagirath;CHO, Guangsup;CHOI, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.156.1-156.1
    • /
    • 2015
  • Neon and argon plasma group velocities (ug) are obtained by intensified charge coupled device (ICCD) camera images at fixed gate width time of 5 ns. The propagation velocities in upstream and downstream region are in the order of 104-105 m/s. The plasma ambipolar diffusion velocities are calculated to be in the order of 101-102 m/s. Plasma jet is generated by sinusoidal power supply in varying voltages from 1 to 4 kV at repetition frequency of 40 kHz. By employing one dimensional convective wave packet model, the neon and argon electron temperatures in non-thermal atmospheric-pressure plasma jet are estimated to be 1.95 and 1.18 eV, respectively.

  • PDF

Understanding of Non-Thermal Atmospheric Pressure Plasma Characteristics Produced in Parallel Plate Type Geometry

  • Choe, Wonho;Moon, Se Youn;Kim, Dan Bee;Jung, Heesoo;Rhee, Jun Kyu;Gweon, Bomi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.144-144
    • /
    • 2013
  • Non-thermal atmospheric pressure plasmas have recently garnered much attention due to their unique physical and chemical properties that are sometimes significantly different from those of low pressure plasmas. It can offer many possible application areas including nano and bio/medical areas. Many different types of plasma sources have been developed for specific needs, which can be one of the important merits of the atmospheric pressure plasmas since characteristics of the produced plasma depend significantly on operating parameters such as driving frequency, supply gas type, driving voltage waveform, gas flow rate, gas composition, geometrical factor etc. Among many source configurations, parallel plate type geometry is one of the simplest configurations so that it can offer many insights for understanding basic underlying physics. Traditionally, the parallel plate type set up has been studied actively for understanding low pressure plasma physics along with extensive employment in industries for the same reason. By considering that understanding basic physics, in conjunction with plasma-surface interactions especially for nano & bio materials, should be pursued in parallel with applications, we investigated atmospheric pressure discharge characteristics in a parallel plate type capacitive discharge source with two parallel copper electrodes of 60 mm in diameter and several millimeters in gap distance. In this presentation, some plasma characteristics by varying many operating variables such as inter-electrode distance, gas pressure, gas composition, driving frequency etc will be discussed. The results may be utilized for plasma control for widening application flexibility.

  • PDF