• Title/Summary/Keyword: Non-magnetic material

Search Result 183, Processing Time 0.027 seconds

Tubular Type Direct Methanol Fuel Cell for in situ NMR Diagnosis (In Situ NMR 진단용 원통형 직접 메탄올 연료전지)

  • Joh, Han-Ik;Um, Myung-Sup;Han, Kee-Sung;Han, Oc-Hee;Ha, Heung-Yong;Kim, Soo-Kil
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.329-334
    • /
    • 2009
  • This study is to develop a fuel cell system applicable to an in situ NMR (Nuclear magnetic resonance) diagnosis. The in situ NMR can be used in real time monitoring of various reactions occurring in the fuel cell, such as oxidation of fuel, reduction of oxygen, transport phenomena, and component degradation. The fuel cell for this purpose is, however, to be operated in a specifically designed tubular shape toroid cavity detector (TCD), which constrains the fuel cell to have a tubular shape. This may cause difficulties in effective mass transport of reactants/products and uniform distribution of assembly pressure. Therefore, a new flow field designed in a particular way is necessary to enhance the mass transport in the tubular fuel cell. In this study, a tubular-shaped close-type flow field made of non-magnetic material is developed. With this flow field, oxygen is effectively delivered to the cathode surface and the produced water is readily removed from the membrane-electrode assembly to prevent flooding. The resulting DMFC (direct methanol fuel cell) outperforms the open-type flow field and exhibits $36\;mW/cm^2$ even at room temperature.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

A Case Study on the MRI Profitability of a General Hospital (한 종합병원의 MRI 채산성 사례 연구)

  • Kang, Chang-Yeol;Song, Sung-Ho;Lim, Kyeong-Tae
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • The purpose of this study is one of high price medical equipment wished to grasp propriety factor about the MRI introduction, analyzing payability through cost accounting into compensation. It was investigated from January 1 to December 31, 2007 about the MRI of a General Hospital. Expectation availability was 23.2 cases, but actual availability did achievement more than 196.1% with 45.5 items. It is estimated that there are a lot of occurrence cases because great reasons that actual availability increases more than expectation availability is excellent resolving power than a CT, and is device that prefer to reason back that radiation damage is less in person body. The followings show the main results of this study. 1. The MRI was construed in order of cost accounting, wave and personnel expenses 45.4%, administrative expenses 53.0%, and material costs 1.6%. 2. According to CVP (Cost-volume-profit) analysis, BEP (Break Even Point) profit is 173,931,428 won for 11 months, and break even usage number of items are 37.5 cases, and separation usage number of items were confirmed by 1.4 cases. Therefore, was construed that can achieve BEP within 11 months though usage number of items keeps 1.4 items day to create the MRI's hospital operation profit. 3. Estimated limit profitability appears high by 96.7%, exceed fixed charges even if when is non-benefit and when it is benefit consider variable, is judged that the MRI's addition induction helps in hospital management enhancing earning rates.

Measurement of Cerebral Blood Volume and Relative Perfusion Rate Mapping Using MR Imaging in Cats

  • Park Byung-Rae;Shin Yong-Wong
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.515-521
    • /
    • 2004
  • To measure regional cerebral blood volume (rCBV) with perfusion MR imaging of cerebral fat embolism by neutral fat and free fatty acids in cats. Triolein (group 1, n=15), oleic acid (group 2, n=9) and linoleic acid (group 3, n=11) were infused into unilateral internal carotid artery using microcatheter through the transfemoral approach. PVA particle was used as a non-fat embolic material in a control group (group 4, n=9). Perfusion-weighted MR image was obtained at 30 minutes and 2 hours postembolization, based on T2-and diffusion-weighted images. The data of lesion and contralateral normal area were transferred to personal computer, time-to-signal intensity curve was drawn and trans for used to △R2/sup */ curve in regular order. The process in the personal computer was done by using the author's developmental image processing program and interactive data language (IDL) softwares. Statistical significance was approved by paired t-test and ANOVA. rCBV of the lesion was decreased comparing to the normal area in all groups. The ratios of rCBV were as follows (group No, at 30 minutes, at 2 hours); group 1,32%, 51%; group 2, 30%, 44%; group 3, 39%, 61%; group 4, 21%, 36%. rCBVs of 2 hours was significantly increased compared to those of 30 minutes in all groups (P<0.005). rCBV was decreased at 30 minutes in cerebral fat embolism and recovered a little, but significantly at 2 hours. Perfusion-weighted images was useful method in offering hemodynamic information in cerebral fat embolism.

  • PDF

Carbonation of coal fly ash for construction materials (탄산화 건자재 제조를 위한 석탄 비산회의 탄산화)

  • Park, Jun-Young;Kim, Yoo-Taek;Kim, Hyun-Jung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.3
    • /
    • pp.147-151
    • /
    • 2012
  • Carbon dioxide ($CO_2$) could be stored in the form of Ca and Mg compounds including alkaline earth metal by carbonation. The possibility of $CO_2$ storage was tested by using desulfurized ash from fluidized bed type boiler as raw material. Autoclave was used for maintaining the reaction pressure and temperature for the carbonation. The analysis of weight change rate, XRD, and TG/DTA proved that more than 15 % of carbonation rate was obtained under 10 $kgf/cm^2$ and $120^{\circ}C$-10 min.

A Light Incident Angle Stimulated Memristor Based on Electrochemical Process on the Surface of Metal Oxide

  • Park, Jin-Ju;Yong, Gi-Jung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.174-174
    • /
    • 2014
  • Memristor devices are one of the most promising candidate approaches to next-generation memory technologies. Memristive switching phenomena usually rely on repeated electrical resistive switching between non-volatile resistance states in an active material under the application of an electrical stimulus, such as a voltage or current. Recent reports have explored the use of variety of external operating parameters, such as the modulation of an applied magnetic field, temperature, or illumination conditions to activate changes in the memristive switching behaviors. Among these possible choices of signal controlling factors of memristor, photon is particularly attractive because photonic signals are not only easier to reach directly over long distances than electrical signal, but they also efficiently manage the interactions between logic devices without any signal interference. Furthermore, due to the inherent wave characteristics of photons, the facile manipulation of the light ray enables incident light angle controlled memristive switching. So that, in the tautological sense, device orienting position with regard to a photon source determines the occurrence of memristive switching as well. To demonstrate this position controlled memory device functionality, we have fabricated a metal-semiconductor-metal memristive switching nanodevice using ZnO nanorods. Superhydrophobicity employed in this memristor gives rise to illumination direction selectivity as an extra controlling parameter which is important feature in emerging. When light irradiates from a point source in water to the surface treated device, refraction of light ray takes place at the water/air interface because of the optical density differences in two media (water/air). When incident light travels through a higher refractive index medium (water; n=1.33) to lower one (air; n=1), a total reflection occurs for incidence angles over the critical value. Thus, when we watch the submerged NW arrays at the view angles over the critical angle, a mirror-like surface is observed due to the presence of air pocket layer. From this processes, the reversible switching characteristics were verified by modulating the light incident angle between the resistor and memristor.

  • PDF

Evidence of Spin Reorientation by Mössbauer Analysis

  • Myoung, Bo Ra;Kim, Sam Jin;Kim, Chul Sung
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.126-129
    • /
    • 2014
  • We report the crystallographic and magnetic properties of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ by means of X-ray diffractometer (XRD), a superconducting quantum interference device (SQUID) magnetometer, and a M$\ddot{o}$ssbauer spectroscopy. In particular, $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was studied by M$\ddot{o}$ssbauer analysis for evidence of spin reorientation. The chalcogenide material $Ni_{0.3}Fe_{0.7}Ga_2S_4$ was fabricated by a direct reaction method. XRD analysis confirmed that $Ni_{0.3}Fe_{0.7}Ga_2S_4$ has a 2-dimension (2-D) triangular lattice structure, with space group P-3m1. The M$\ddot{o}$ssbauer spectra of $Ni_{0.3}Fe_{0.7}Ga_2S_4$ at spectra at various temperatures from 4.2 to 300 K showed that the spectrum at 4.2 K has a severely distorted 8-line shape, as spin liquid. Electric quadrupole splitting, $E_Q$ has anomalous two-points of temperature dependence of $E_Q$ curve as freezing temperature, $T_f=11K$, and N$\acute{e}$el temperature, $T_N=26K$. This suggests that there appears to be a slowly-fluctuating "spin gel" state between $T_f$ and $T_N$, caused by non-paramagnetic spin state below $T_N$. This comes from charge re-distribution due to spin-orientation above $T_f$, and $T_N$, due to the changing $E_Q$ at various temperatures. Isomer shift value ($0.7mm/s{\leq}{\delta}{\leq}0.9mm/s$) shows that the charge states are ferrous ($Fe^{2+}$), for all temperature range. The Debye temperature for the octahedral site was found to be ${\Theta}_D=260K$.

Observation of an Ellerman bomb and its associated surge with the 1.6 meter New Solar Telescope at Big Bear Solar Observatory

  • Yang, Heesu;Chae, Jongchul;Park, Hyungmin;Maurya, Ram Ajor;Cho, Kyuhyun;Kim, Yeon-Han;Cho, Il-Hyun;Lim, Eun-Kyung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.111.2-111.2
    • /
    • 2012
  • We observed an Ellerman bomb(EB) and its associated surge using the Fast Imaging Solar Spectrograph(FISS) and the broadband TiO filter of the 1.6 meter New Solar Telescope at Big Bear Solar Observatory. As is well-known, the EB appears as a feature that is very bright at the far wings of the H alpha line. The lambdameter method applied to these wings indicates that the EB is blue-shifted up to 6km/s in velocity. In the photospheric level below the EB, we see rapidly growing "granule-like" feature. The transverse velocity of the dark lane at the edge of the "granule" increased with time as reached a peak of 6km/s, at the time of the EB's occurrence. The surge was seen in absorption and varied rapidly both in the H alpha and the Ca II 8542 line. It originated from the Ellerman bomb, and was impulsively accelerated to 20km/s toward us(blueshift). Then the velocity of the surge gradually changed from blueshift of 20km/s to redshift of 40km/s. By adopting the cloud model, we estimated the temperature of the surge material at about 27000K and the non-thermal velocity at about 10km/s. Our results shed light on the conventional idea that an EB results from the magnetic reconnection of an emerging flux tube and pre-existing field line.

  • PDF

Analysis on Electromagnetic Loss Characteristics of Bus bar and Enclosure according to the Specifications of Enclosures for a 24kV Switchgear (24kV급 배전반의 외함재질과 두께에 따른 Bus bar와 외함의 전자기 손실특성 분석)

  • Heo, Jeong Il;Hong, Jonggi;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.181-185
    • /
    • 2013
  • This paper deals with the electromagnetic loss characteristics of enclosures for a 24kV high voltage switchgear by using a finite element method (FEM). A study on the electromagnetic characteristics of enclosures for a high voltage switchgear should be conducted to minimize the size and the temperature rising of a switchgear. Generally, the enclosures made by stainless steel are used to minimize the eddy current loss caused by the transporting current in Bus bars due to its non-magnetic characteristics although the price of stainless steel is expensive compared with other metal for enclosures. Therefore, a switchgear made by stainless steel enclosures could be fabricated as a small size and are applied to a switchgear in urban substations. On the contrary, the switchgear enclosures made by steel could be fabricated with relatively cheap manufacturing price. However, the temperature easily rises due to the transporting current in Bus bars because steel is a ferromagnetic material. Therefore, the size of a switchgear made by steel enclosures is relatively massive and installed in rural substations. In this paper, the electromagnetic losses in the enclosures of a switchgear according to various enclosure thicknesses are calculated and compared with each other. Especially, we proposed a hybrid type enclosures for a switchgear made by stainless steel (top and bottom enclosure) and steel (left and right enclosure). It is concluded that the cost electromagnetic performance of applying the hybrid type enclosure is favorable to develop a high voltage switchgear.

Design of 1 MW High-temperature Superconducting Motor with Water-cooled Armature (수냉식 전기자로 구성된 1 MW 고온초전도 동기모터의 설계)

  • Baik, S.K.;Lee, J.D.;Kim, S.H.;Lee, E.Y.;Sohn, M.H.;Kwon, Y.K.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Lee, J.Y.;Hong, J.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1258-1260
    • /
    • 2005
  • Superconducting synchronous motors and generators have the field coil composed of superconductor with almost zero resistance at superconducting state. Therefore, co or loss at the conventional field coil is eliminated and the superconducting machine gets higher efficiency. The armature coil of the superconducting machine is composed of cower wire and supported by non-magnetic material such as FRP(Fiber Reinforced Plastic). Although a fully-superconducting machine with superconducting armature coil has been researched, it was not developed toward industrial application because of AC transporting loss and difficulty in construction of the cooling structure and so on. This paper contains the design procedure of a 1 MW superconducting synchronous motor using high-temperature superconductor only for the field coil. Especially, the armature coil is designed by water-cooling in order to dissipate Joule heat easily. Moreover, 3-dimensional electromagnetic design is conducted to get a proper design result and reduce design errors from 2-dimensional approach.

  • PDF