• 제목/요약/키워드: Non-isolated inverter

검색결과 8건 처리시간 0.02초

A Family of Non-Isolated Photovoltaic Grid Connected Inverters without Leakage Current Issues

  • Ji, Baojian;Wang, Jianhua;Hong, Feng;Huang, Shengming
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.920-928
    • /
    • 2015
  • Transformerless solar inverters have a higher efficiency than those with an isolation link. However, they suffer from a leakage current issue. This paper proposes a family of single phase six-switch transformerless inverter topologies with an ac bypass circuit to solve the leakage current problem. These circuits embed two unidirectional freewheeling current units into the midpoint of a full bridge inverter, to obtain a freewheeling current path, which separates the solar panel from the grid in the freewheeling state. The freewheeling current path contains significantly fewer devices and poor performance body diodes are not involved, leading to a higher efficiency. Meanwhile, it is not necessary to add a voltage balancing control method when compared with the half bridge inverter. Simulation and experiments are provided to validate the proposed topologies.

A Dual Buck Three-Level PV Grid-Connected Inverter

  • Ji, Baojian;Hong, Feng;Wang, Jianhua;Huang, Shengming
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.910-919
    • /
    • 2015
  • The use of a PV grid-connected inverter with non-isolated topology and without a transformer is good for improving conversion efficiency; however, this inverter has become increasingly complicated for eliminating leakage current. To simplify the complicated architecture of traditional three-level dual buck inverters, a new dual Buck three-level PV grid-connected inverter topology is proposed. In the proposed topology, the voltage on the grounding stray capacitor is clamped by large input capacitors and is equal to half of the bus voltage; thus, leakage current can be eliminated. Unlike in the traditional topology, the current in the proposed topology passes through few elements and does not flow through the body diodes of MOSFET switches, resulting in increased efficiency. Additionally, a multi-loop control method that includes voltage-balancing control is proposed and analyzed. Both simulation and experimental results are demonstrated to verify the proposed structure and control method.

플라이백 컨버터를 이용한 인버터 직류링크 전압의 절연 궤환 (Isolated Feedback of Inverter DC-Link Voltage Using Flyback Converters)

  • 김경서
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.281-285
    • /
    • 2018
  • An isolated feedback method for measuring the inverter DC-link voltage is proposed. This method provides a simple and economical solution to inverter control systems that use a flyback converter as a controller power supply. In the proposed method, data on the DC-link voltage are acquired when the primary side voltage appears on the secondary side of the flyback transformer, thereby eliminating the need to adopt an extra signal isolation method. To solve the non-synchronization problem between the flyback converter switching and main controller sampling, the external interrupt function of the micro-controller is used as a trigger signal for the A/D conversion.

Extended Boost Single-phase qZ-Source Inverter for Photovoltaic Systems

  • Shin, Hyun-Hak;Cha, Honnyong;Kim, Hongjoon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.918-925
    • /
    • 2014
  • This study presents an extended boost single-phase qZ-source DC-AC inverter for a single-phase photovoltaic system. Unlike the previously proposed single-phase qZ-source and semi-qZ-source inverters that achieve the same output voltage as that of the traditional voltage-fed full-bridge inverter, the proposed inverter can obtain higher output than input voltage. The proposed inverter also shares a common ground between DC input voltage and AC output voltage. Thus, possible ground leakage current problem in non-isolated grid-tied inverters can be eliminated with the proposed inverter. A 120 W prototype inverter is built and tested to verify the performance of the proposed inverter.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

Fiber Sensor와 X-Y Robot을 이용한 용접선 추적에 관한 연구 (Study on the Seam Tracking by Using Fiber Sensor and X-Y Robot)

  • 배철오;박영산;이성근;김윤식;안병원
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.144-149
    • /
    • 2001
  • 산업현장의 열악한 작업중의 하나인 용접작업을 자동화하기 위한 방법으로 본 논문은 비접촉식 센서인 Fiber Sensor를 이용하여 용접선을 1차적으로 추적하고, 추적한 데이터를 텍스트 파일로 저장함과 통시에 2차적으로 추적한 용접선을 X-Y 로봇의 좌표값으로 다시 출력하여 용접을 하도록 하고 있다. Fiber Sensor를 통하여 읽어 들인 데이터는 Delphi Version 3.0을 이용하여 만들어진 프로그램을 통하여 처리하였고, I/O 입출력은 16 채널의 Relay Actuator 출력과 16 채널의 opto-isolated 입력이 가능한 PC의 ISA슬롯에 직접 삽입하여 사용하는 카드를 통해서 이루어졌다. 본 실험에서 용접선 추적은 직선, 기울기를 가진 직선 및 곡선에 관하여 추적을 행하였고, 추적한 데이터를 토대로 인버터 $CO_2$ 용접기를 사용하여 용접을 행하여 보았다.

  • PDF

Fiber Sensor와 X-Y Robot을 이용한 용접선 추적에 관한 연구 (Study on the Seam Tracking by Using Fiber Sensor and X-Y Robot)

  • 배철오;이성근;김윤식;안병원;박영산
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.558-561
    • /
    • 2000
  • 산업 현장의 열악한 작업중의 하나인 용접작업을 자동화하기 위한 방법으로 본 논문은 비접촉식 센서인 Fiber Sensor를 이용하여 용접선을 1차적으로 추적하고, 추적한 데이터를 텍스트 파일로 저장함과 동시에 2차적으로 추적한 용접선을 X-Y 로봇의 좌표값으로 다시 출력하여 용접을 하도록 하고 있다 Fiber Sensor를 통하여 읽어 들인 데이터는 Delphi Version 3.0을 이용하여 만들어진 프로그램을 통하여 처리하였고, I/O 입출력은 16 채널의 Relay Actuator 출력과 16 채널의 opto-isolated 입력이 가능한 PC의 ISA 슬롯에 직접 삽입하여 사용하는 카드를 통해서 이루어졌다. 본 실험에서 용접선 추적은 직선, 기울기를 가진 직선 및 곡선에 관하여 추적을 행하였고, 추적한 데이터를 토대로 인버터 CO2용접기를 사용하여 용접을 행하여 보았다.

  • PDF