• Title/Summary/Keyword: Non-humidified

Search Result 18, Processing Time 0.031 seconds

Development of Nursing Practice Guidelines for Non-humidified Low Flow Oxygen Therapy by Nasal Cannula (비강 캐뉼라를 이용한 저유량 산소 요법에서 비가습 적용의 간호실무 가이드라인 개발)

  • Nam, Ae-Ri-Na;Bae, Woo-Hyun;Park, Mi-Mi;Ko, Eun-Jeong;Park, Byung-Nam;Park, Jeong-Ok;Yim, Ji-Yeoung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.19 no.1
    • /
    • pp.87-94
    • /
    • 2013
  • Purpose: The purpose of this study was to provide a basis for non-humidified low flow oxygen by nasal cannula and to provide a guide for consistent care in nursing practice. Methods: A methodological study on the development of guidelines with experts' opinions on collected items, framing PICO questions, evaluating and synthesizing texts which were searched with the key words (low flow oxygen, nasal cannula, humidification of oxygen, guideline) from web search engines. Results: Of the 45 researched texts on the web, 9 texts relevant to the theme were synthesized and evaluated. All patients with humidified or non-humidified oxygen therapy reported that they had no discomfort. Conclusion: The results indicate that there are no tangible grounds for patients' perceived differences between the humidified and non-humidified oxygen under 4L/min supplied by nasal cannula. with oxygen. Therefore, non-humidification oxygen therapy is strongly advised when suppling under 4L/min oxygen by nasal cannula (recommended grade A).

The Effects of Intra-operative Heated Humidification on Body Temperature, Blood Pressure and Shivering of Patients Undergoing General Anesthesia (수술 중 흡입가스의 가온가습이 체온, 혈압 및 떨림에 미치는 효과 -일반회로 적용군과의 후향적 비교연구-)

  • Bae, Ik Lyul;Hur, Myung Haeng
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.192-203
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the body temperature (BT), blood pressure (BP) and shivering in patients undergoing operation under general anesthesia between the heated humidification circuit tube (HHCT) group and the non-HHCT group. Methods: Data were extracted from the participants' medical records from September 1st to December 30th, 2009. The HHCT group consisted of 50 cases who were applied with heated and humidified gas via a specially designed circuit under general anesthesia. The HHCT which was adjusted at $41^{\circ}C$ was applied from induction of general anesthesia to extubation. In comparison, the non-HHCT group consisted of 50 cases who were applied with gas through standard breathing circuit without heat and humidification. Collected data were analyzed by $x^2$ test, t-test and repeated measures ANOVA. Results: The BT and shivering were significantly different between two groups (p<.001). But the BP was was not signigicantly different between the HHCT group and the non-HHCT group. Conclusion: The application of heated and humidified gases to patients under general anesthesia was effective in preserving the body temperature and reducing the shivering.

The Characteristics of Attrition of Absorbents for Pre-combustion CO2 Capture (연소 전 CO2 포집 흡수제들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Moon, Jongho;Park, Youngcheol;Jo, Sungho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.5
    • /
    • pp.428-436
    • /
    • 2013
  • Attrition characteristics of $CO_2$ absorbents for pre-combustion $CO_2$ capture were investigated to check attrition loss of those absorbents and to determine solid circulation direction and the better $CO_2$ absorbent. The cumulative attrition losses of two absorbents increased with increasing time. However, attrition loss under a humidified condition was lower than that under a non-humidified condition case. Between two absorbents, attrition loss of PKM1-SU absorbent was higher than that of P4-600 absorbent. The average particle sizes of the attrited particles were less than $2.5{\mu}m$ for two absorbents under a non-humidified condition case, and therefore, we could conclude that the main mechanism of attrition for two absorbents is not fragmentation but abrasion. Based on the results from the test for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor. Attrition loss and make-up rate of two absorbents were compared based on the results from $CO_2$ sorption capacity tests and attrition tests. Required make-up rate of P4-600 absorbent was lower than that of PKM1-SU absorbent. However, more detail investigation on the optimum regeneration temperature, manufacturing cost, solid circulation rate, regeneration rate, and long-term sorption capacity should be considered to select the best $CO_2$ absorbent.

Observation of local water content and current density in the PEMFC system (고분자 전해질 연료전지의 전류밀도와 국소 함수량 관찰)

  • Ko, Dong-Soo;Moon, Cheor-Ron;Choi, Gyung-Min;Kim, Duck-Jool;Jung, Ji-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.69-72
    • /
    • 2008
  • The local water contents and water transfer characteristics in the PEMFC system were investigated by numerical simulations and experiments. The performance of a lab-scale PEMFC is measured for fully humidified gases conditions and non-humidified ones. In order to observe the local water contents and water transfer characteristics inside PEMFC, the numerical simulation using CFD module on STAR-CD(es-pemfc) were conducted. The results show that the water content was increased as increasing current density, whereas it was decreased in high current density region. Then there was close correlation between high water content and internal temperature inside of MEA, and high current density was observed when internal temperature was dramatically increased.

  • PDF

Developement of a PEFC electrodes under the high temperature and low humidified conditions (고온/저 가습 운전을 위한 고분자 전해질 연료전지용 전극 개발)

  • Ryu, Sung-Kwan;Choi, Young-Woo;Park, Jin-Soo;Yim, Sung-Dae;Yang, Tae-Hyun;Kim, Han-Sung;Kim, Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.149-149
    • /
    • 2009
  • Generally, Nafion ionomer is used in the polymer electrolyte fuel cell (PEFC) electrodes to achieve high power density. At the high temperature operation of PEFC, however, ionic conductivity of Nafion remarkably decreased due to the evaporation of water in Nafion polymer. Recently, many researchers have focused on using the Ionic Liquids(ILs) instead of water in Nafion polymer. ILs have intrinsic properties such as good electrochemical stability, high ionic conductivity, and non-flammability. Especially, ILs play a crucial role in proton conduction by the Grottuss mechanism and act as water in water-free Nafion polymer. However, it was found that the ILs was leached out of the polymer matrix easily. In this study, we prepared membrane electrode assemblies with various contents of ILs. The effect of ILs in the electrode of each designed was investigated by a cyclic voltammetry measurement and the cell performance obtained through a single cell test using H2/Air gases. Electrodes with different contents of ILs in catalyst layer were examined at high temperature and low humidified condition.

  • PDF

Attrition Characteristics of WGS Catalysts for SEWGS System (SEWGS 시스템을 위한 WGS 촉매들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Lee, Seungyong;Jin, Gyoungtae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.122-130
    • /
    • 2014
  • Attrition characteristics of WGS catalysts for pre-combustion $ CO_2$ capture were investigated to check attrition loss of those catalysts, to check change of particle size distribution during attrition tests, and to determine solid circulation direction of WGS catalysts in a SEWGS system. The cumulative attrition losses of two catalysts increased with increasing time. However, attrition loss under humidified condition was lower than that under non-humidified condition case for long-term attrition tests. Between two catalysts, attrition loss of PC-29 catalyst was higher than that of commercial catalyst for long-term attrition tests. However, the commercial catalyst generated much more fines than PC-29 catalyst during attrition. Therefore, we conclude that the PC-29 catalyst is more suitable for fluidized bed operation if we take into account the separation efficiency of cyclone. Based on the results from the tests for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor.

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF

Numerical Study for the Effect of Inlet Humidity Condition at PEMFC Channel (전산해석을 통한 고분자 전해질 연료전지 내 입구 가습조건의 영향에 관한 연구)

  • Lee Dong-Ryul;Ahmed Dewan Hasan;Bae Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1228-1235
    • /
    • 2006
  • PEMFC(Proton Exchange Membrane Fuel Cell) is a low temperature fuel cell and has many probabilities of commercial use. However, water management is one of the serious technical problems for commercialization. It is necessary to understand the relationship between operation conditions and water behavior in PEMFC channel because it affects fuel cell performance. In this paper, the distribution of current density according to inlet humidity condition is mainly observed and discussed. If the anode inlet is well humidified, electro-osmotic drag is very active. For this reason, current density is very high at inlet side and the distribution is non-uniform.

Mesoporous SiO2 Mediated Polybenzimidazole Composite Membranes for HT-PEMFC Application (고온 PEMFC 응용을 위한 다공성 SiO2 기반 폴리벤즈이미다졸 복합막)

  • HAN, DAEUN;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.128-135
    • /
    • 2019
  • In this study, the mesoporous $SiO_2$ (5, 10, or 15 wt%) was incorporated into the polybenzimidazole matrix in order to improve the proton conduction as well as physiochemical properties of composite membrane. The chemical structure of mesoporous $SiO_2$ and crystallinity of as-prepared membranes were analyzed by Fourier-transform infrared (FT-IR) spectroscopy and X-ray diffraction (XRD) analysis, respectively. The thermal stability of the pristine $X_1Y_9$ and composite membranes were evaluated by thermogravimetric analyzer (TGA). On other side, the physical and chemical properties of the pristine $X_1Y_9$ and composite membranes were also determined by acid uptake and oxidative stability tests, respectively. With the incorporation of 15 wt% $SiO_2$, the composite membrane exhibits the higher proton conductivity that may be applicable for non-humidified high temperature fuel cell applications.

Effect of Humidified High Flow CO2 Gas Insufflation on the Coronary Endothelium (가습화한 고유량의 이산화탄소가스 통기가 관상동맥 내피세포층에 미치는 영향)

  • 최재성;김준성;서정욱;김기봉
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.131-138
    • /
    • 2004
  • High-flow gas insufflation to get a bloodless field during off-pump coronary artery bypass may have adverse effects on the coronary endothelium. This study was designed (1) to elucidate the effect of carbon dioxide gas insufflations on the coronary endothelium at different flow rates and (2) to assess the protective effect of humidifcation against the coronary endothelial damage. Material and Method: In nine pigs, the left anterior descending coronary artery (LAD) was exposed after a median sternotomy. The LAD was divided into 4 segments and a coronary arteriotomy was made in each LAD segment in the beating heart. The far distal arteriotomy was exposed to room air for 10 minutes and was harvested as a control. Non-humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group I), humidified carbon dioxide gas at a continuous flow rate of 5 L/min (Group II), and humidified carbon dioxide gas at a continuous flow rate of 10 L/min (Group III) were insufflated for 10 minutes on each coronary arteriotomy site, respectively. After harvesting the coronary segments, hematoxylin-eosin staining, elastic fiber staining, and immunostaining with a CD34 monoclonal antibody were performed to evaluate the depth of endothelial damage and to count the residual endothelial cells, Result: In all three groups (Group I, II, and III), internal elastic laminae were preserved, however, the endothelial layers were significantly damaged by carbon dioxide gas insufflation. The mean percentages of remaining endothelial cells were 20,9$\pm$16.7%, 39.3$\pm$19.6%, and 6.8$\pm$5.3%, in groups I, II, and III, respectively. The percentages of remaining cells were significantly higher in group II than in groups I and III (p=0.008). The percentages of remaining cells were significantly higher in group I than in group III (p=0.008). Conclusions: The harmful effect of carbon dioxide gas insufflation on the coronary endothelium was dependent on the flow rate. The addition of humidification did not protect the coronary endothelium from denudation injury caused by high flow carbon dioxide gas insufflations.