• 제목/요약/키워드: Non-direct measurement

검색결과 128건 처리시간 0.027초

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • 제2권1호
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

A Direct Integration Approach for the Estimation of Time-Dependent Boundary Heat Flux

  • Kim, Sin;Kim, Min-Chan;Kim, Kyung-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1320-1326
    • /
    • 2002
  • In a one-dimensional heat conduction domain with heated and insulated walls, an integral approach is proposed to estimate time-dependent boundary heat flux without internal measurements. It is assumed that the expression of the heat flux is not known a priori. Hence, the present inverse heat conduction problem is classified as a function estimation problem. The spatial temperature distribution is approximated as a third-order polynomial of position, whose four coefficients are determined from the heat fluxes and the temperatures at both ends at each measurement. After integrating the heat conduction equation over spatial and time domain, respectively, a simple and non-iterative recursive equation to estimate the time-dependent boundary heat flux is derived. Several examples are introduced to show the effectiveness of the present approach.

광삼각법을 이용한 고반사 BGA 볼의 정밀 높이 측정 방법 (3D Accuracy Enhancement of BGA Shiny Round Ball Using Optical Triangulation Method)

  • 주병권;조택동
    • 한국정밀공학회지
    • /
    • 제32권9호
    • /
    • pp.799-805
    • /
    • 2015
  • The further development of information, communication and digital media technologies requires the use of advanced, miniaturized semiconductor chips that operate at a high frequency. Die bonding and wire bonding methods for semiconductor packaging have been replaced by direct attachment to the substrate after forming a bump on the chip. However, the height of the bump or ball is an important factor for defects during assembly. This paper proposes an algorithm to measure the height of the bumps or balls in semiconductor packaging with greater accuracy. The performance of the proposed algorithm is experimentally validated. Non-contact 3D measurements of a shiny round ball is quite difficult, and it is not easy to obtain accurate data. This paper thus proposes an optical method and technique to improve the measurement accuracy.

CW 레이저 스페클 사진법에 의한 스트레인 측정에 관한 연구 (A Study of Strain measurement by continuous wave Laser speckle photography)

  • 김경석;김충원;이승건
    • 한국정밀공학회지
    • /
    • 제7권2호
    • /
    • pp.65-73
    • /
    • 1990
  • Speckle photography is a simple non-contacting method for analysing surface displacement. In its basic form, the object to be studied is illuminated with a beam of laser light from any convenient direction, and a double exposure photography of the surface recorded on the fine-grain film, the object is undergone the displacement to be measured between exposures. Like this, it allows the strain field to be evaluated in two dimensions. A direct experimental comparison of speckle photography with theoretical value on a notched tensile test specimen showed that serious errors could, however, occur due to local surface tilting and due to aberra- tions of the imaging lens. Methods of minimising these effects and those of the speckle de-correlation which occurs by the various conditions are discussed.

  • PDF

칼라 영상처리에 의한 과일분류시스템 (Classification system of fruits by color image processing)

  • 최연호;부기동;구본호
    • 한국산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.65-70
    • /
    • 2000
  • 일반적으로 농산물의 품질은 무게나 크기 등을 직접 측정하여 판정하거나 간접 또는 비파괴방법을 이용하여 판정하게 된다. 본 논문에서는 비파괴를 이용한 판정방법인 칼라 영상처리를 이용하여 농산물의 품질과 등급을 결정하는 알고리즘을 개발하여, 이를 실시간 귤 분류시스템에 적용하였다. 개발된 시스템은 귤의 크기와 색상을 칼라 영상처리 하여 초당 최대 6개를 실시간 분류 할 수 있는 성능을 가지고 있다. 또한 다른 농산물의 품질판정을 위한 제어기를 설계할 경우에도 본 논문에서 개발한 알고리즘이 적용될 수 있을 것으로 기대된다.

  • PDF

Mobility-Spectrum Analysis of an Anisotropic Material System with a Single-Valley Indirect-Band-Gap Semiconductor Quantum-Well

  • Joung, Hodoug;Ahn, Il-Ho;Yang, Woochul;Kim, Deuk Young
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.774-783
    • /
    • 2018
  • Full maximum-entropy mobility-spectrum analysis (FMEMSA) is the best algorithm among mobility spectrum analyses by which we can obtain a set of partial-conductivities associated with mobility values (mobility spectrum) by analyzing magnetic-field-dependent conductivity-tensors. However, it is restricted to a direct band-gap semiconductor and should be modified for materials with other band structures. We developed the modified version of FMEMSA which is appropriate for a material with a single anisotropic valley, or an indirect-band-gap semiconductor quantum-well with a single non-degenerate conduction-band valley e.g., (110)-oriented AlAs quantum wells with a single anisotropic valley. To demonstrate the reliability of the modified version, we applied it to several sets of synthetic measurement datasets. The results demonstrated that, unlike existing FMEMSA, the modified version could produce accurate mobility spectra of materials with a single anisotropic valley.

돼지 임신 진단을 위한 Heterologous ELISA 법 개발 (Development of Heterologous ELISA System for Diagnosis of Pregnancy in Swine)

  • 박성민;이안나;윤택준;박용수;송태준;김영훈;안효선;박원철;김종배
    • Reproductive and Developmental Biology
    • /
    • 제34권3호
    • /
    • pp.161-167
    • /
    • 2010
  • Early diagnoses of pregnancy for animal such as swine and bovine is extremely important to increase income of a farmhouse and for the management of farm. For the development of immunoasaay system of pregnancy in swine, we report a competitive heterologous enzyme linked immunosorbent assay (ELISA) for the direct measurement of oestrone sulfate (E1S) in diluted urine using anti-E1G (glucuronide) monoclonal antibody which cross react with ElS. The principle of assay was based on the typical solid-phase competitive ELISA methods using E1G-HRP (horseradish peroxidase) as a tracer and E1S for standard. The method had a reasonable sensitivity for the detection of E1S with 0.15 ng/ml as a detection limit. The intra-assay and inter-assay precisions were raging coefficient of from 8.50~9.67% and 8.50~9.87%, respectively, which were quite acceptable. In a field trial with a group 37 sows (18 non-pregnancy and 19 pregnancy sows) after day 29~30 post service, the concentration of E1S were determined to be below 30 ng/ml in all non-pregnancy group and over 48 ng/ml in pregnancy group except one sample. The method described here, heterologous ELISA for the measurement of E1S in urine is good enough for monitoring the early pregnancy test of swine.

달 탐사 로버의 적응형 움직임 가중치에 따른 스테레오 준직접방식 비주얼 오도메트리 (Stereo Semi-direct Visual Odometry with Adaptive Motion Prior Weights of Lunar Exploration Rover)

  • 정재형;허세종;박찬국
    • 한국항공우주학회지
    • /
    • 제46권6호
    • /
    • pp.479-486
    • /
    • 2018
  • 위성항법시스템이 없는 달 표면에서 탐사 로버의 신뢰성 있는 항법성능을 확보하기 위해 관성측정장치나 카메라와 같은 추가적인 센서를 활용한 항법 알고리즘이 필수적이다. 일례로 미국의 화성 탐사 로버에 스테레오 카메라를 이용한 비주얼 오도메트리(VO)가 성공적으로 사용된 바 있다. 본 논문에서는 달 유사환경의 스테레오 흑백 이미지를 입력받아 달 탐사 로버의 6 자유도 움직임을 추정하였다. 제안하는 알고리즘은 희소 이미지 정렬 기반의 준직접방식 VO를 통해 연속된 이미지간의 상대 움직임을 추정한다. 또한 비선형성에 취약한 직접방식 VO를 보완하고자 최적화 시 로버의 움직임에 따른 가중치를 비용 함수에 고려하였고, 그 가중치는 이전 단계에서 계산된 포즈의 선형 함수로 제안한다. 본 논문에서 제안하는 로버의 움직임에 따른 가중치를 통해 실제 달 환경의 특성을 반영하는 토론토 대학의 달 유사환경 데이터셋에서 VO 성능이 향상됨을 확인하였다.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.