• Title/Summary/Keyword: Non-dimensional Temperature

Search Result 262, Processing Time 0.025 seconds

A study on inhomogeneity of YBCO Coated Conductors using Low-temperature Scanning Laser Microscopy (LTSLM) (저온 주사 레이저 현미경(LTSLM)을 이용한 YBCO 초전도 선재의 불균질성 연구)

  • Park, S.K.;Kim, J.M.;Lee, S.B.;Kim, S.H.;Kim, G.Y.;Ri, H.C.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.72-77
    • /
    • 2009
  • Low temperature scanning laser microscopy (LTSLM) can be used for a two-dimensional display of bolometric response arising from the localized excitation of a sample by the focused laser beam. In this study, the distribution of critical temperature ($T_c$) and critical current density ($J_c$) in YBCO coated conductor were analyzed using LTSLM. For improving the temperature stability, we have modified the system into a double-shielding type. Through the modification, the temperature stability was successfully improved from ${\pm}10mK\;to\;{\pm}2mK$. The superconducting properties of YBCO coated conductors were measured for the sample of a narrow bridge type using wet etching process. The spatial non-uniformity of the ac voltage response, ${\delta}V(x)$, which is proportional to ${\partial}\rho(x,J_B)/{\partial}T$ in the transition temperature region could be observed and displayed in a two-dimensional image.

  • PDF

Measurement of Reynolds Number Effects on Cavitation Performance in a Turbopump Inducer (레이놀즈 수가 터보펌프 인듀서 캐비테이션 성능에 미치는 영향 측정)

  • Kim, Junho;Song, Seung Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.820-823
    • /
    • 2017
  • This study experimentally investigate how the Reynolds number affect cavitation performance in a turbopump inducer using water. Cavitation performance has been determined by the static pressure measured at the inlet of the inducer. Reynolds number has been varied by varying water temperature and inducer rotational speed to maintain constant non-dimensional thermal parameter. At low non-dimensional thermal parameter, the critical cavitation number is insensitive to Reynolds number. However, at high non-dimensional thermal parameter, the critical cavitation number increased as Reynolds number increases. Thus, cavitation performance is deteriorated as Reynolds number increases when thermal effect exists.

  • PDF

Response of rotational parameter in the stagnation point with motile microorganism: Unsteady nanofluid

  • Mohamed A. Khadimallah;Imene Harbaoui;Sofiene Helaili;Abdelhakim Benslimane ;Humaira Sharif ;Muzamal Hussain;Muhammad Nawaz Naeem;Mohamed R. Ali;Aqib Majeed;Abdelouahed Tounsi
    • Advances in concrete construction
    • /
    • v.15 no.4
    • /
    • pp.241-249
    • /
    • 2023
  • The unsteady mixed convection Casson type MHD nanofluid flow in the stagnation point with motile microorganism around a spinning sphere is investigated. Time dependent flow dynamics is considered. Similarity transformations have been employed to transfer the governing partial differential structure into ordinary differential structure. The impact of distinct parameters is examined via tables and graphs. The impact of rotational parameter (spin) on profiles of velocity profiles, temperature and concentration is revealed for unsteady mixed convection Casson type MHD nanofluid flow. It is observed that it is clear that rotational parameter has a great effect on non-dimensional primary velocity component but rotational parameter has a slight impact on non-dimensional secondary velocity component. The validity of the current investigation is authorized through comparing the existing outcomes with previous published literature.

Analyzing the Influence of Spatial Sampling Rate on Three-dimensional Temperature-field Reconstruction

  • Shenxiang Feng;Xiaojian Hao;Tong Wei;Xiaodong Huang;Pan Pei;Chenyang Xu
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.246-258
    • /
    • 2024
  • In aerospace and energy engineering, the reconstruction of three-dimensional (3D) temperature distributions is crucial. Traditional methods like algebraic iterative reconstruction and filtered back-projection depend on voxel division for resolution. Our algorithm, blending deep learning with computer graphics rendering, converts 2D projections into light rays for uniform sampling, using a fully connected neural network to depict the 3D temperature field. Although effective in capturing internal details, it demands multiple cameras for varied angle projections, increasing cost and computational needs. We assess the impact of camera number on reconstruction accuracy and efficiency, conducting butane-flame simulations with different camera setups (6 to 18 cameras). The results show improved accuracy with more cameras, with 12 cameras achieving optimal computational efficiency (1.263) and low error rates. Verification experiments with 9, 12, and 15 cameras, using thermocouples, confirm that the 12-camera setup as the best, balancing efficiency and accuracy. This offers a feasible, cost-effective solution for real-world applications like engine testing and environmental monitoring, improving accuracy and resource management in temperature measurement.

Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

  • Choi, Yoon-Sil;Oh, Jae-Woon;Lee, Young;Lee, Dong-Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.5
    • /
    • pp.411-421
    • /
    • 2022
  • Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve-incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity. Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36℃ was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer. Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group. Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.

Analysis on the Thermal Characteristics of Variable Conductance Heat Pipe (가변 컨덕턴스 히트파이프의 열특성에 관한 해석)

  • 김근오;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.38-47
    • /
    • 2001
  • The operation characteristics of variable conductance heat pipe(VCHP) were numerically investigated by using 1-dimensional diffuse-front model. For different boundary conditions, the amount of non-condensible gas charge and dimension of gas reservoir were obtained by iterative calculation. It is found that the amount of non-condensible gas charge and dimensions of gas reservoir have an effect on the temperature control of condenser for the given operating condition of VCHP. The numerical results show that VCHP has an excellent capability of temperature control when subjected to a change in the heat input.

  • PDF

Numerical simulation of non-isothermal flow in oil reservoirs using a two-equation model

  • dos Santos Heringer, Juan Diego;de Souza Debossam, Joao Gabriel;de Souza, Grazione;Souto, Helio Pedro Amaral
    • Coupled systems mechanics
    • /
    • v.8 no.2
    • /
    • pp.147-168
    • /
    • 2019
  • This work aims to simulate three-dimensional heavy oil flow in a reservoir with heater-wells. Mass, momentum and energy balances, as well as correlations for rock and fluid properties, are used to obtain non-linear partial differential equations for the fluid pressure and temperature, and for the rock temperature. Heat transfer is simulated using a two-equation model that is more appropriate when fluid and rock have very different thermal properties, and we also perform comparisons between one- and two-equation models. The governing equations are discretized using the Finite Volume Method. For the numerical solution, we apply a linearization and an operator splitting. As a consequence, three algebraic subsystems of linearized equations are solved using the Conjugate Gradient Method. The results obtained show the suitability of the numerical method and the technical feasibility of heating the reservoir with static equipment.

Analytical analysis for the forced vibration of CNT surrounding elastic medium including thermal effect using nonlocal Euler-Bernoulli theory

  • Bensattalah, Tayeb;Zidour, Mohamed;Daouadji, Tahar Hassaine
    • Advances in materials Research
    • /
    • v.7 no.3
    • /
    • pp.163-174
    • /
    • 2018
  • This article studies the free and forced vibrations of the carbon nanotubes CNTs embedded in an elastic medium including thermal and dynamic load effects based on nonlocal Euler-Bernoulli beam. A Winkler type elastic foundation is employed to model the interaction of carbon nanotube and the surrounding elastic medium. Influence of all parameters such as nonlocal small-scale effects, high temperature change, Winkler modulus parameter, vibration mode and aspect ratio of short carbon nanotubes on the vibration frequency are analyzed and discussed. The non-local Euler-Bernoulli beam model predicts lower resonance frequencies. The research work reveals the significance of the small-scale coefficient, the vibrational mode number, the elastic medium and the temperature change on the non-dimensional natural frequency.

Three-dimensional cure simulation of composite structures by the finite element method (유한요소법을 이용한 복합재 구조물의 3차원 경화 수치모사)

  • Min, Kuoung-Jae;Park, Hoon-Cheol;Yoon, Kwang-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.39-45
    • /
    • 2002
  • In this paper, a finite element formulation was introduced for the three-dimensional cure simulation of composite structures. Based on the formulation, a three-dimensional finite element code was developed. Numerical examples found in the literatures were solved for code verification. Results from the present analyses agreed well with the measured cure-induced temperatures. Unlike in one or two dimensional analysis, temperature and degree of cure were able to be calculated at any point within composite structures in the present analysis. The finite element program can be used for the cure simulation of composite structures with arbitrary geometry under non-uniform autoclave temperature distribution.

A Finite Element Analysis of Non-Isothermal Sheet Metal Forming Process (비등온 박판 성형공정의 유한요소해석)

  • ;Wagoner, R. H.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1119-1128
    • /
    • 1990
  • A numerical method for analyzing non-isothermal, rigid-viscoplastic deformation problems has been presented. As an application, a stretch forming of sheet metals, including temperature effect, has been analyzed by a three-dimensional finite element method. Bishop`s step-wise decoupled method is adopted to solve thermomechanical coupling between deformation and heat transfer. Using the method, the effect of temperature on strain distribution during stretch forming is investigated. By comparison of the non-isothermal results with isothermal analysis, the importance of including temperature effects in the analysis of metal forming problems is emphasized. The predicted results were in good agreement with the existing experimental measurements at the different punch temperatures and dome heights investigated. It is also found that any increase of the punch temperature appeared to postpone the strain localization process by lowering the peak strain in the critical punch-sheet contact region and by normalizing strain distribution within the specimen.