• 제목/요약/키워드: Non-destructive test

검색결과 471건 처리시간 0.039초

FT-NIR을 이용한 상추(Lactuca sativa L) 종자의 비파괴 선별 기술에 관한 연구 (Study on non-destructive sorting technique for lettuce(Lactuca sativa L) seed using fourier transform near-Infrared spectrometer)

  • 안치국;조병관;강점순;이강진
    • 농업과학연구
    • /
    • 제39권1호
    • /
    • pp.111-116
    • /
    • 2012
  • Nondestructive evaluation of seed viability is one of the highly demanding technologies for seed production industry. Conventional seed sorting technologies, such as tetrazolium and standard germination test are destructive, time consuming, and labor intensive methods. Near infrared spectroscopy technique has shown good potential for nondestructive quality measurements for food and agricultural products. In this study, FT-NIR spectroscopy was used to classify normal and artificially aged lettuce seeds. The spectra with the range of 1100~2500 nm were scanned for lettuce seeds and analyzed using the principal component analysis(PCA) method. To classify viable seeds from nonviable seeds, a calibration modeling set was developed with a partial least square(PLS) method. The calibration model developed from PLS resulted in 98% classification accuracy with the Savitzky-Golay $1^{st}$ derivative preprocessing method. The prediction accuracy for the test data set was 93% with the MSC(Multiplicative Scatter Correction) preprocessing method. The results show that FT-NIR has good potential for discriminating non-viable lettuce seeds from viable ones.

비파괴 및 재하시험에 의한 노후 교량의 거동특성 (Behavior Properties of Bridge by Non Destructive and Loading Test)

  • 민정기;김영익
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.61-71
    • /
    • 2004
  • The performance evaluation and deflection of 3 spans concrete simplicity slab bridge analyzed by non-destructive and loading test. Compressive strength of slab and pier appeared in the range of each 353∼366 kgf/$cm^2$ and 152∼215 kgf/$cm^2$ in rebound number test. Also, it appeared that concrete quality of slab was good after performance improvement. The average compressive strength of slab by core picking appeared 229 kg/$cm^2$. In reinforcing bar arrangement test of span and member, it appeared that horizontal and vertical reinforcing bar was arranged to fixed interval. The value of calculation deflection that carried structural analysis with deflection analysis wave in static loading test appeared higher than that of experimental deflection and it appeared that hardness of this bridge was good. Maximum impact factor that estimated from deflection by running speed in dynamic loading test appeared by 0.216 in 10 km/hr running speed.

반발 경도법의 고강도 콘크리트 적용성 검토 (A Study on application of High Strength Concrete by Non-Destructive Test)

  • 김희두;임성주;박용규;김현우;윤기원;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.69-70
    • /
    • 2013
  • This is an foundational study to adequacy the non-destruction testing for the estimation of compressive strength of high strength concrete The results are as follows, In high strength concrete, H type is NR type rebound number rather than higher. The relation between rebound number and compressive strength of high strength concrete have lower coefficient. when compressive strength estimation of high strength concrete, it consider that rebound hardness test is not applied and should be consider to combined method or addition method.

  • PDF

탐상조건 예측을 위한 초음파 시뮬레이션 (Ultrasonic Simulation for Test Condition Estimate)

  • 허선철;박영철;이광영;박원조
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.37-44
    • /
    • 2001
  • Ultrasonic testing has a characteristics such as excellent permeability, high-sensitivity to find defect and an almost exact measurement for position. size and direction of inner defect, which differ from other non-destructive testing. In the study, we developed program into optimal testing condition, to distinguish obstacle echo and defect position. This program shows generation and processing of ultrasonic pulse. We compared simulation with ultrasonic test in 45$^\circ$, 60$^\circ$and 70$^\circ$transducer. Test results were in accordance with simulation within 0.1~7.2%.

  • PDF

화재 피해를 입은 고강도 철근 콘크리트 압축부재의 비파괴 검사 (Non destructive test of Fire-damaged reinforced concrete columns with high strength concrete)

  • 서지민;이수진;최은규;신영수;이차돈;권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.13-16
    • /
    • 2005
  • This study is aimed to investigate the strength variation of fire-damaged reinforced concrete column by non-destructive test. It is studied to infer the recovery degree of residual strength of fire-damaged concrete. For measuring the surface hardness of RC columns. Schmidt hammer test is used. Testing is performed three-times: before fire test, directly after fire test and after 20 days.

  • PDF

적외선 열화상에 의한 숏크리트 보강사면의 비접촉 비파괴 시험 (The Non-Destructive and Non-Contact Test Using Infrared Thermal Technique on Reinforced Slopes by Shotcrete)

  • 이종영;신창건;장범수;손종철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.622-628
    • /
    • 2004
  • In general, Reinforced Slopes by Shotcrete are difficult to inspect because of stiff Slope and highly Working Area. So the Inspection Techniques are needed by the Non-contact and Non-destructive. On this Study, Appling the safety method to finding the weak zones(cavity area, dampness area, etc.) by using the Infrared Thermal Technique That is detecting the Detail Thermal Difference on the Surface of Reinforced Slopes by Shotcrete.

  • PDF

조기강도 콘크리트의 압축강도 추정을 위한 비파괴검사 실험식의 제안 (Suggestion for Non-Destructive Testing Equation to Estimate Compressive Strength of Early Strength Concrete)

  • 이태규;강연우;최형길;최경철;김규용
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.229-235
    • /
    • 2016
  • 현장에서는 콘크리트 공사시 거푸집 탈형작업을 위한 다양한 기술들이 활용되고 있다. 그중에서 콘크리트의 압축강도추정을 위한 비파괴 시험방법에는 다양한 방법들이 제시되고 있지만, 일반적으로 타격법(반발경도법이라 칭함)과 비타격법(초음파법이라 칭함)을 활용한 시험방법이 주로 활용된다. 비파괴시험에 의한 압축강도의 추정은 경험 값에 의한 방정식에 의하여 계산할 수 있으며 다양한 식들이 제시되고 있으나, 초기재령에서 조기강도가 발현되는 콘크리트에 대한 데이터는 적은 편으로 기존의 강도추정식에 의한 압축강도의 계산에는 한계점이 있을 수 있다. 본 연구에서는 현장에서 주로 활용되는 조기탈형용 콘크리트의 배합을 활용하여 소형 공시체 및 Mock-up 시험체의 파괴 및 비파괴검사를 수행하였으며, 기존 비파괴검사 추정식을 통한 강도 결과 값을 분석하였다. 실험결과, 기존 연구의 비파괴시험에 의한 제안식을 활용한 압축강도 추정값은 파괴시험방법에 비하여 하회하는 경향으로 70% 이하의 값을 나타냈으며, 초음파속도에 의한 신뢰성은 강도가 높아질수록 낮아지는 것으로 확인되었다. 본 연구의 범위에서 조기강도 발현 콘크리트의 강도추정에 있어 기존식의 활용의 한계점이 있을 것으로 분석되어, 24~60MPa의 콘크리트를 대상으로 반발경도법 및 초음파속도법에 의한 추정식을 제안하였다.

내부결함 검출 가능한 저주파 ECT 센서개발(I) - 전자기 유도기전력 손실량의 특성- (Development of New Low Frequency ECT Sensor to Detect Inner Defects(I) - Characteristic of Loss of Induced Electromotive Force -)

  • 박정웅;장문석;김국주;김범기
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.57-62
    • /
    • 2015
  • Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing(ECT) is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. The New ECT sensor which can detect inner defects was developed regardless the condition of surface. This sensor is verified to do experiment which measure the loss of induced electromotive force. The loss of induced electromotive force was measured in 5.4% and this low frequency ECT device can detect internal defects at depth 20 mm.

내부결함 검출 가능한 저주파 ECT 센서개발(II) - 결함을 가진 소형 용접시험편에 적용 - (Development of New Low Frequency ECT Sensor to Detect Inner Defects(II) - Application to Welding Specimens Included Defects -)

  • 박정웅;장문석;김국주;김범기
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.63-67
    • /
    • 2015
  • Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing(ECT) is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. The New ECT sensor which can detect inner defects was developed regardless the condition of surface. This sensor is verified to do experiment which measure the loss of induced electromotive force. The loss of induced electromotive force was measured in 5.4% and this low frequency ECT device can detect internal defects at depth 20 mm.

Research on non-destructive testing technology for existing bridge pile foundations

  • Zhang, Xue-feng;Ni, Ying-sheng;Song, Chunxia;Xu, Dong
    • Structural Monitoring and Maintenance
    • /
    • 제7권1호
    • /
    • pp.43-58
    • /
    • 2020
  • Pile foundations of existing bridges lie in soil and water environment for long term and endure relatively heavy vertical loads, thus prone to damages, especially after stricken by external forces, such as earthquake, collision, soil heap load and etc., and the piles may be injured to certain degrees as well. There is a relatively complete technical system for quality inspection of new bridge pile foundations without structures on the top. However, there is no mature technical standard in the engineering community for the non-destructive testing technology specific to the existing bridge pile foundations. The quality of bridge pile foundations has always been a major problem that plagues bridge maintenance. On the basis of many years' experiences in test engineering and theoretical studies, this study developed a new type of detection technology and equipment for the existing bridge piles.