• 제목/요약/키워드: Non-contact glass

검색결과 70건 처리시간 0.037초

Al계 초소성합금과 Zr계 비정질합금의 마이크로 진동성형에 관한 연구 (A Study on the Micro Vibration Forming of Al-based Superplastic Alloy and Zr-based Bulk Metallic Glass)

  • 손선천;박규열;나영상
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.193-200
    • /
    • 2007
  • Micro forming is a suited technology to manufacture very small metallic parts(several $mm{\sim}{\mu}m$). Al5083 superplastic alloy with very small grains has a great advantage in achieving micro deformation under low stress due to its relatively low strength at a specific high temperature range. Micro forming of $Zr_{62}Cu_{17}Ni_{13}Al_8$ bulk Metallic glass(BMG) as a candidate material for this developing process are feasible at a relatively low stress in the supercooled liquid state without any crystallization during hot deformation. In this study, the micro formability of Al5083 superplastic alloy and bulk metallic glass, $Zr_{62}Cu_{17}Ni_{13}Al_8$, was investigated with the specially designed micro vibration forming system using pyramid-shape, V-shape and U-shape micro die pattern. With these dies, micro vibration forming was conducted by varying the applied load, time. Micro formability was estimated by comparing the hight of formed shape using non-contact surface profiler system. The vibration load effect to metal flow in the micro die and improve the micro formability of Al5083 superplastic alloy and $Zr_{62}Cu_{17}Ni_{13}Al_8$ bulk Metallic glass(BMG).

다양한 교정용 접착제의 표면거칠기와 표면에너지 요소 분석 (Surface roughness and surface free energy components of various orthodontic adhesives)

  • 안효범;안석준;남동석
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.360-368
    • /
    • 2006
  • 치과용 재료의 표면특성은 세균 부착에 중요한 역할을 한다. 본 연구의 목적은 다섯 종류의 광중합 교정용 접착제(불소를 방출하지 않는 세 종류의 콤포지트 레진, 불소를 방출하는 콤포지트 레진 한 종류, 레진 변형 글래스아이오노머 시멘트 한 종류)의 표면특성을 평가하는 것이다. 표면거칠기는 공초점 레이저주사전자현미경을 이용하여 측정하였고, 접촉각과 표면에너지 요소는 sessile drop method를 이용하여 분석하였다. 본 연구의 결과 교정용 접착제간 표면거칠기는 각 재료간 표면거칠기 차이가 $0.05\;{\mu}m$ 이하로 상대적으로 적지만 각 재료 사이에 유의성 있는 차이를 보였다. Transbond XT와 Enlight는 Monolok2와 Lightbond 보다 유의하게 덜 거칠었다. 접촉각과 표면에너지 구성성분은 접착제 사이에 유의성 있는 큰 차이를 보였는데 특히 레진 변형 글래스아이오노머와 콤포지트 레진 접착제간에 접촉각과 표면에너지에서 커다란 차이를 보였다. 레진 변형 글래스아이오노머의 경우 콤포지트 레진 접착제에 비해 유의하게 작은 접촉각과 높은 표면에너지를 보였으며 콤포지트 레진 접착제보다 강한 극성, 특히 강한 염기성 경향을 보였다 본 연구는 레진 변형 글래스아이오노머가 콤포지트 레진 접착제에 비해 세균 부착에 유리한 환경을 제공한다는 것을 보여주었다.

유리섬유/에폭시 복합절연재료의 계면 접착력 개선에 관한 연구(2) - 절연특성 향상에 관하여 - (A Study on the Adhesive Improvement of Glass cloth/Epoxy Composite Insulating Materials(2) - For Improvement of Wettability on the Interface -)

  • 김순태;황영한;박홍태;엄무수;이규철;이종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1061-1065
    • /
    • 1995
  • To improve dielectric and mechanical properties of insulating composite by plasma surface treatment, new plasma surface treatment process is designed with concentric and hemi-circle electrodes system, the plasma, which is generated between anode and cathode, is induced to the upper side of the electrode system and treats the surface of the insulators. The optimal surface treatment condition is that pressure : 0.5[torr], flux density 100[gauss], discharge current : 500[mA] and treatment time : 3 minutes. The composite filled with glass cloth surface-treated by plasma shows the improvement in electric and mechanical properties, comparing non- and coupling agent-treated samples.

  • PDF

감광성 고분자 범프와 NCA (Non-Conductive Adhesive)를 이용한 COG 접합에서의 불량 (Failure in the COG Joint Using Non-Conductive Adhesive and Polymer Bumps)

  • 안경수;김영호
    • 마이크로전자및패키징학회지
    • /
    • 제14권1호
    • /
    • pp.33-38
    • /
    • 2007
  • 본 실험에서는 Non-Conductive Adhesive (NCA) 와 고분자 범프를 이용한 COG (Chip-on-glass) 접합에 대하여 연구하였다. 산화막이 증착된 Si 기판 위에 고분자 범프를 사진식각 방법으로 형성하고, 고분자 범프 위에 직류 마그네트론 스퍼터링 방법으로 금속 박막층을 증착하였다. 기판으로는 Al을 증착한 유리기판을 사용하였다. 두 종류의 NCA를 사용하여 $80^{\circ}C$에서 하중을 변화시켜가며 접합을 실시하였다. 접합부의 특성을 평가하기 위하여 4단자 저항 측정법을 이용하여 접합부의 접속 저항을 측정하였으며, 주사전자현미경을 이용하여 접합부를 관찰하였다. 신뢰성은 $0^{\circ}C$$55^{\circ}C$ 사이에서 열충격 실험을 2000회까지 실시하여 평가하였다. 신뢰성 측정 전 접합부의 저항 값은 $70-90m{\Omega}$을 나타내었다. 200MPa 이상의 접합 압력에서는 고분자 범프가 NCA 의 필러 파티클에 의해 손상된 것을 관찰하였다. 신뢰성 측정 후 일부 범프가 fail 되었는데 범프의 fail 원인은 범프의 윗부분보다 상대적으로 금속층이 얇게 증착된 범프의 모서리 부분의 금속층의 끊어졌기 때문이었다.

  • PDF

NCA 물성에 따른 극미세 피치 COG (Chip on Glass) In, Sn 접합부의 신뢰성 특성평가 (Improvement of Reliability of COG Bonding Using In, Sn Bumps and NCA)

  • 정승민;김영호
    • 마이크로전자및패키징학회지
    • /
    • 제13권2호
    • /
    • pp.21-26
    • /
    • 2006
  • NCA의 물성이 미세피치 Chip on glass (COG) 접합부의 신뢰성에 미치는 영향을 연구하였다. Si 위에 Sn을, 유리기판 위에 In을 열증발 방법으로 증착하고 lift-off 방법을 이용하여 $30{\mu}m$ 피치를 가지는 솔더범프를 형성하였으며 열압착 방법으로 $120^{\circ}C$에서 In 범프와 Sn 범프를 접합하였다. 접합할 때 세 종류의 Non conductive adhesive (NCA)를 적용하였다. 신뢰성은 $0^{\circ}C$$100^{\circ}C$ 사이로 열충격시험을 2000회까지 실시하여 평가하였다. 4단자 저항측정법을 이용하여 접합부의 저항을 측정하였다. 필러의 양이 증가할수록 열충격시험 후 접합부의 저항이 가장 적게 증가하여 신뢰성이 우수하였다. 필러의 양이 증가할수록 NCA의 열팽창이 작아지기 때문이다.

  • PDF

치과용 고주파 주조기를 위한 비접촉 단일 온도센서 설계 (Design of a non-contacting single infrared sensor for high frequency dental casting machine)

  • 황인;원용관;이상훈;송성근
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1546-1552
    • /
    • 2016
  • 일반적으로 치과용 주조기는 불때를 이용하여 합금을 용해하기 때문에 합금의 적절한 용융온도 및 주조시간을 조절하기 어렵고 이로 인해 가스공이나 핀홀과 같은 주조결함을 발생시키며 과열로 인한 보철물의 결함을 보이고 있다. 또한 합금이 용융된 후 주조 시 대부분 투시창이나 비접촉식 온도센서를 부착하여 적절한 주조온도가 되면 작업자가 원심력을 발생하는 버튼을 눌러 도가니에 용융된 합금을 주조링에 주입한다. 이러한 결과로 대부분 주조온도가 너무 높거나 낮아서 주조결함을 많이 발생하고 있으며 균일한 주조체를 얻지 못하고 있는 실정이다. 본 논문에서는 외부의 비접촉식 온도 센서를 이용한 온도계측이 아닌 실제 합금의 사용 온도를 계측할 수 있는 단일 온도센서를 이용한 치과용 고주파 주조기를 개발하였다.

Computational optimized finite element modelling of mechanical interaction of concrete with fiber reinforced polymer

  • Arani, Khosro Shahpoori;Zandi, Yousef;Pham, Binh Thai;Mu'azu, M.A.;Katebi, Javad;Mohammadhassani, Mohammad;Khalafi, Seyedamirhesam;Mohamad, Edy Tonnizam;Wakil, Karzan;Khorami, Majid
    • Computers and Concrete
    • /
    • 제23권1호
    • /
    • pp.61-68
    • /
    • 2019
  • This paper presents a computational rational model to predict the ultimate and optimized load capacity of reinforced concrete (RC) beams strengthened by a combination of longitudinal and transverse fiber reinforced polymer (FRP) composite plates/sheets (flexure and shear strengthening system). Several experimental and analytical studies on the confinement effect and failure mechanisms of fiber reinforced polymer (FRP) wrapped columns have been conducted over recent years. Although typical axial members are large-scale square/rectangular reinforced concrete (RC) columns in practice, the majority of such studies have concentrated on the behavior of small-scale circular concrete specimens. A high performance concrete, known as polymer concrete, made up of natural aggregates and an orthophthalic polyester binder, reinforced with non-metallic bars (glass reinforced polymer) has been studied. The material is described at micro and macro level, presenting the key physical and mechanical properties using different experimental techniques. Furthermore, a full description of non-metallic bars is presented to evaluate its structural expectancies, embedded in the polymer concrete matrix. In this paper, the mechanism of mechanical interaction of smooth and lugged FRP rods with concrete is presented. A general modeling and application of various elements are demonstrated. The contact parameters are defined and the procedures of calculation and evaluation of contact parameters are introduced. The method of calibration of the calculated parameters is presented. Finally, the numerical results are obtained for different bond parameters which show a good agreement with experimental results reported in literature.

Product Analysis and Development of Amblyopia Eye Patch for Children

  • Lim, Hosun;Sung, Juyoung
    • Fashion, Industry and Education
    • /
    • 제14권2호
    • /
    • pp.1-10
    • /
    • 2016
  • In the present study, the materials, sizes, and designs of blind eye patch products of skin-adhesive type and glass-attachment type currently available in the market will be analyzed and ergonomically appropriate blind eye patches will be developed. Although these skin-adhesive type eye patches were easy to use, they had shortcomings such as skin troubles due to the adhesive used on the weak and sensitive skin of children and the fact that eyebrows are pulled out and the skin is irritated when the eye patches are detached after being attached. The non-adhesive type eye patches were blind patches to be worn by putting into glasses. These products were made using diverse materials such as neoprene, non-woven fabrics, and felt and showed differences in tactile impressions and irritation to the skin depending on material characteristics. In addition, most products were efficient in blocking light with three-dimensional oval designs comprising darts. In the present study, blind eye patches were designed to reduce skin troubles by using sweat-absorbing and quick-drying functional materials with soft tactile impressions. In addition, to increase the effect to block light and the degree of tight contact with the skin when the blind eye patches are worn compared to existing eye patch designs, the sides of the wings of the blind eye patches were widened, glass frame fixing plates were added, and the darts were made to be curved thereby making an ergonomic design reflecting the shape of the face. The non-adhesive type blind eye patches developed in the present study are considered to enhance the wearing sensation with the use of the material without skin irritation but with cushioning feelings and the ergonomic design reflecting the contour of the face.

Dual Nano-Electrospray and Mixing in the Taylor Cone

  • Radionova, Anna;Greenwood, David R.;Willmott, Geoff R.;Derrick, Peter J.
    • Mass Spectrometry Letters
    • /
    • 제7권1호
    • /
    • pp.21-25
    • /
    • 2016
  • Dual-channel nano-electrospray has recently become an ionization technique of great promise especially in biological mass spectrometry. This unique approach takes advantage of the mixing processes that occurs during electrospray. Understanding in more detail the fundamental principles influencing spray formation further study of the origins of the mixing processes: (1) in a Taylor cone region, (2) in charged droplets or (3) in both environments. The dual-channel emitters were made from borosilicate theta-shape glass tubes (O.D. 1.2 mm) and had a tip diameters of less than 4 μm. Electrical contact was achived by deposition of a thin film of an appropriate metal onto the surface of the emitter. The experimental investigation of the Taylor cone formation in a dual-channel electrospray emitter has been carried out by injection of polystyrene beads (diameter 3 μm) at very low concentrations into one of the channels of the non-tapered theta-glass tubes. High-speed camera experiments were set up to visualize the mixing processes in Taylor cone regions for dual-channel emitters. Mass spectra from dual nano-electrospray are presented.

공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석 (Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System)

  • 노태정;손태영
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.878-885
    • /
    • 2008
  • 최근에 많은 수요와 각광을 받고 있는 디스플레이 장치에서 CRT는 곡면이며 무겁고 큰 부피 때문에 LCD, PDP, OLED와 같은 평판디스플레이(FPD)로 대체되고 있다. FPD는 $0.6\sim0.8mm$ 두께의 대면적 글래스에 여러 공정을 거친 후에 최종 제품 규격으로 절단하여 제작하기 때문에 글래스의 면적이 크면 클수록 FPD의 생산성이 높다는 밀접한 관계를 갖는다. 따라서 FPD 제조 업계에서는 글래스 면적을 증가시키기 위하여 노력하고 있으며, 예를 들면, 현재 8세대 LCD인 경우 약 $2,200mm\times2,600mm$의 면적을 가진다. 이러한 글래스를 이송하는 대표적인 장치로서 공기부상 컨베어시스템은 압축공기를 이용해서 FPD용 대면적 글래스 등을 약 $0.3\sim0.5mm$ 정도 부상시켜 비접촉으로 이송할 수 있는 장치이다. 이 때 글래스와 다공질판 표면 사이의 공기 유동이 모델링되고 해석되며, 이것으로부터 글래스의 공기부양 조건이 예측될 수 있다. 글래스를 이송시 전기공급 중단에 의하여 압축공기가 공급되지 않아 부상판과 접촉이 발생하였을 때, 자기윤활 특성을 가진 다공질판 위의 글래스는 1mm 홀을 많이 가진 사각덕트 부상판 위의 글래스와 조사, 비교된다.