Browse > Article
http://dx.doi.org/10.6109/jkiice.2016.20.8.1546

Design of a non-contacting single infrared sensor for high frequency dental casting machine  

Hwang, In (School of Electronics and Computer Engineering, Chonnam National University)
Won, Yonggwan (School of Electronics and Computer Engineering, Chonnam National University)
Lee, Sang-Hun (Department of Electrical Engineering, Dong-Eui Institute of Technology)
Song, Sung-Geun (KETI, Energy Conversion Research Center)
Abstract
In addition, because it uses preheating to dissolve an alloy in general, it is hard to regulate the appropriate melting temperature of the alloy and brewing time and shows the defect of the supplementation thing due to the super-heating. Once the alloy is molten and then most of the casting by attaching a sight glass or non-contact temperature sensor is suitable casting temperature the operator pressing a button to generate a centrifugal force to inject the molten alloy into a crucible in the casting ring. These results, and most of the cast temperature is too high or too low to generate a lot of casting defects do not get into a uniform cast body. In this paper, we developed a dental casting machine for high frequency using a single temperature sensor which can measure the actual temperature of the alloy than the temperature of the external non-contact measurement using a temperature sensor.
Keywords
Casting machine for dental; Auto-casting; Melting temperature; Non-contacting method; Temperature sensor;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Hong-Sam Kim "A study on new software switching high frequency inverter for induction heating," Kyungnam Univ a master's thesis, 2008.
2 G. P. Cho et al, "Characteristics analysis of time sharing method VVVF type high frequency resonant inverter," JIEIE, vol 16, no.3 pp. 20-28, July 2002.
3 G. P. Cho et al, "A Study on Characteristics Analysis of Time Sharing Type High Frequency Inverter Consisting of Three Unit Half-Bridge Serial Resonant Inverter," JIEIE, vol 15, no.1 pp .90-97, 2001.
4 J. H. Yoo, and D. C. Shin, "A Study on the Frequency Control on the Induction Heating System Using Two Step Resonant Inverter," JIEIE, vol 22, no.1 pp. 95-103, June 2008.
5 S. I. Hong and E. S. Son, "Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating Application," JIEIE, vol 14, no.6 pp. 12-17, July 2000.
6 H. Yu, H. Xudong, J. sheng, "A Novel Load Adaptive Zero Voltage Switching Utilizing Diode Reverse Recovery Current for Soft-Switching Choppers and Inverters," PESC, Conference Proceedings, vol. 1, pp. 146-151. Feb. 2001.