• Title/Summary/Keyword: Non-Point Source Pollutant

Search Result 249, Processing Time 0.026 seconds

A Study on the Characteristics of Pollutant loads runoff in the Drainage Area of Mangyeong River (만경강 유역의 오염부하 유출특성에 관한 연구)

  • Eom, Myung-Chul;Lee, Kwang-Ya;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.607-610
    • /
    • 2003
  • The object of this study is to analyze the characteristics of pollutant loadings on rainy day compared with normal day in the Mangyeong catchment area of Saemangeum tidal reclaimed area. On rainy day, the concentrations of BOD, COD, T-N and T-P are smaller than those on normal day, in spite of the pollutant loading themselves are increased significantly on rainy day due to non point source pollution, such as CSOs(combined sewage overflows), runoff from agricultural land use and so on.

  • PDF

Characteristics of Runoff Load from Nonpoint Source Pollutants in the Lake Doam Watershed (도암호 유역에서 비점오염물질의 유출부하 특성)

  • Kwak, Sungjin;Bhattrai, Bal Dev;Gim, Giyoung;Kang, Phil-Goo;Heo, Woomyung
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.1
    • /
    • pp.135-147
    • /
    • 2018
  • In order to investigate the runoff characteristics of nonpoint source pollutants in the Lake Doam watershed, water quality and flow rate were monitored for 38-rainfall events from 2009 to 2016. The EMC values of SS, COD, TN and TP were in the range of 33~2,169, 3.5~56.9, 0.09~7.65 and $0.06{\sim}2.21mg\;L^{-1}$, respectively. As a result of analyzing the effect of rainfall factor on the nonpoint source pollutant load, EMCs of SS, COD and TP showed a statistically significant correlation with rainfall (RA) (p<0.01) and SS showed highly significant correlation with maximum rainfall intensity (MRI, R=0.48). The load ranges of SS, COD, TN and TP were 10.4~11,984.6, 1.1~724.4, 0.6~51.6 and $0.03{\sim}22.85ton\;event^{-1}$, respectively, showing large variation depending on the characteristics of rainfall events. The effect of rainfall on the load was analyzed. SS, COD and TP showed a positive correlation, but TN did not show any significant correlation. The annual load of SS was the highest with $88,645tons\;year^{-1}$ in 2011 when rainfall was the highest with 1,669 mm. The result of impact analysis of nonpoint source pollution reduction project and land-use change on runoff load showed that pollutant load significantly reduced from 2009 to 2014 but SS and TP loads were increased from 2014 to 2016 due to increase in construction area. Therefore, we suggested that nonpoint source pollution abatement plan should be continued to reduce the soil loss and pollutants during rainfall, and countermeasures to reduce nonpoint source pollution due to construction need to be established.

Drainage and Treatment Characteristics of Runoff by Media (여재에 따른 도로면 유출수의 배수 및 처리특성)

  • Kim, Seog-gu;Yun, Sang-Ieen;Kim, Young-im;Lee, Yong-jae;Kim, Ree-ho;Kim, Jong-oh
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.500-505
    • /
    • 2004
  • While more attention has been paid in recent years to urban point source pollution control, no considerable measures have been taken to control urban non-point source pollution. Contaminants from non-point sources deposited on urban impermeable surfaces such as road and highway are easily released to the public waters by rainfall, leading to the deterioration in water quality in urban area. The present study investigated a system using filter media to reduce the level of contamination in urban road runoff. Three different media, designated as J-P (polypropylene, blowing type), B-P (polypropylene, fiber type), and P-F (Polyvinyl alcohol, cube and sheet type) were evaluated on the basis of pollutant removal efficiency as well as hydraulic property. Experiments were peformed using a 1/4-scale treatment unit at various pollutant roading and rainfall intensity with real rainwater runoff collected from road surfaces. The results at different rainfall intensities shows that the medium J-P is superior to the other media for water permeability. J-P was not blocked at 10 mm/hr rainfall and its permeability was stable. On the other hand, B-P and P-F resulted in substantial overflow ratio even at I mm/hr rainfall intensity. Comparing treatment efficiencies for suspended solids, all media showed similar removal ranged from 91 % to 95%. However, J-P seems to be better than the other media considering its higher water permeability. J-P and P-F, both hydrophobic, yielded over 76% of heavy metal removal. But, the hydrophilic media B-P showed much smaller removal ranging from 26% to 47%. This indicates that J-P and P-F are beneficial to remove heavy metal due to their hydrophobic property. The treatment efficiencies over PAHs (poly aromatic hydrocarbons) showed the similar removal efficiency ranging from 66% to 97% for all three media.

Watershed Modeling Research for Receiving Water Quality Management in Hwaseong Reservoir Watershed (화성호 유역의 수질관리를 위한 유역모델링 연구)

  • Jang, Jae-Ho;Kang, Hyeong-Sik;Jung, Kwang-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.819-832
    • /
    • 2012
  • HSPF model based on BASINS was applied for the Hwaseong Reservoir watershed (HRW) to evaluate the feasibility of water quality management. The watershed was divided into 45 sub-basins considering various watershed environment. Streamflow was calibrated based on the measured meteorological data, discharge data of treatment plants and observed streamflow data for 2010 year. Then the model was calibrated against the field measurements of water qualities, including BOD, T-N and T-P. In most cases, there were reasonable agreements between observed and predicted data. The validated model was used to analyze the characterization of pollutant load from study area. As a result, Non-point source pollutant loads during the rainy season was about 66~78% of total loads. In rainy-season, water quality parameters depended on precipitation and pollutant loads patterns, but their concentration were not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. As another result of evaluation for load duration curves, in order to improve water qualities to the satisfactory level, the watershed managements considering both time-variant and pollution sources must be required in the HRW. Overall, it was found that the model could be used conveniently to assess watershed characteristics and pollutant loads in watershed scale.

Development of River Quality Management Information System Using Web-GIS of Nonsan-si(I) (Web-GIS를 이용한 논산시 하천수질 관리 정보 지원시스템 구현(I))

  • 박기학;오승교;박성규
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.15-23
    • /
    • 2003
  • The purpose of this study is to construct e-Nonsan, a user friendly river quality management information system for Nonsan-si basin using GIS (geographical information system) technology. GIS was ideally suited featuring a geographical characteristics(e.g., industries, cattle sheds) and very effectively used in mapping and symbolization for the distribution of the spatial/periodic status(e.g., pie or column chart) of the point/non-point pollutant source loads which can be effectively applied to a information system on the web-site. And a user interface, GUI(graphic user interface) was designed very diversely and simply enabled the and non environmental experts connect with the system and obtain a useful information of river quality. e-Nonsan, a visual mapping system for river quality was developed by reframing the monitoring data as graphic symbols and it was ideally suited to exploring area-wide river quality at a user-friendly manner due to extensibility and scalability along the various survey points. Eventually the final step of this study was to construct e-Nonsan based on Web-GIS could be assessed anywhere if internet service is available and offer a very useful information services of the river quality to the publics.

A study on water quality change by land use change using HSPF

  • Kim, Tae Geun;Choi, Kyoung-sik
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.123-128
    • /
    • 2020
  • Non-point source pollutant load reductions were calculated using the Hydrologic Simulation Program-Fortran (HSPF) model under the assumption that landuse pattern was changed according to land purchases. Upon the simulation of non-point pollutant and areas with high land purchase ratios to select a buffer zone, the Namgang dam Reach 11, Imha dam Reach 10, and the Reach 136 watershed of the main river were found to rank high for the construction of buffer zones. Assuming that the forms of the purchased lands were changed to wetlands, biological oxygen demand (BOD) loads were changed through the HSPF model. No changes of BOD were present in the Namgang dam and the Imha dam watersheds. BOD loads in Reach 136 according to landuse change were analyzed through a flow duration analysis based on the total maximum daily loads of the United States. The flow duration analyses undertaken to examine changes in BOD of main river Reach 136 watershed indicated a shift of 0.64 kg/d from 3.16 to 2.52 during high flow. The change of BOD under the conditions of moist, mid-range and dry were 11.9%, 9% and 4.5%. At the low flow condition, the variation range in the BOD load was from 0.58 kg/d to 0.41 kg/d.

Application of FDC and LDC using HSPF Model to Support Total Water Load Management System (오염총량관리제 지원을 위한 유역모형 기반 유량지속곡선 및 부하지속곡선 활용방안)

  • Lee, Eun Jeong;Kim, Tae Geun;Keum, Ho Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.33-45
    • /
    • 2018
  • In this study, we discussed the application of Watershed model and Load Duration Curves (LDC) in Total Water Load Management System. The Flow Duration Curves (FDC) and the LDC were generated using the results of the daily HSPF model and analyzed on monthly or yearly flow duration variability, and non-point pollutant discharge loads by entire flow conditions. As a result of the calibration and verification of the HSPF model, both the flow and the water quality were appropriately simulated. The simulated values were used to generate the Flow Duration Curve and the Load Duration Curve, and then the excess rate by entire flow conditions was analyzed. The point and non-point pollutant discharge loads for entire flow conditions were calculated. It is possible to evaluate the variability of water quality in specific flow duration through the curves reflecting the flow duration variability and to confirm the characteristics of the pollutant source. For a more scientific Total Water Load Management System, it is necessary to switch from a current system to a system that can take into account the entire flow conditions. For this, the application of the watershed model and load duration curve is considered to be the best alternative.

Runoff Characteristics of Non-Point Sources on the Stormwater (강우에 의한 도로 비점오염원 유출 특성)

  • Kim, Seog-Ku;Kim, Young-Im;Kang, Sung-Won;Yun, Sang-Leen;Kim, So-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.104-110
    • /
    • 2006
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Accordingly, release of contaminants from non-point sources, released with surface runoff of rainwater, is influenced by atmospheric phenomena, geology, and topography. This makes the control of non-point source difficult. Therefore, this study intends to reveal the characteristics of runoff and particle size distribution to observe the fundamental characteristics of runoff. Experiments were carried out at inner road of research center. Average concentration of runoff ranged from 26.8 to 126.4 mg/L for SS and $COD_{Cr}\;15.3{\sim}117.7mg/L,\;TN\;0.07{\sim}5.16mg/L,\;TP\;0.06{\sim}0.49mg/L$ and heavy metals $0.00{\sim}0.29mg/L$. First flush, indicated wash off of pollutant at first rain, was observed for all types of pollutants. Most pollutants revealed a very close correlation with SS ($R^2=0.93{\sim}0.99$). After analyzing characteristics of particle, particle was finer than that from previously examined data.

The Application of Nature-Based Technologies for Addressing Urban Environmental Problems (도시 환경 문제를 해결하기 위한 자연 기반해법의 적용)

  • Haque, Md Tashdedul;Reyes, Nash Jett DG.;Lee, Jung-min;Guerra, Heidi B.;Jeon, Minsu;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.367-376
    • /
    • 2022
  • LID technologies are capable of mitigating the negative impacts of non-point source (NPS) pollution generated in different land uses. Apart from the increase in point and non-point pollutant generation, highly developed and paved areas generally affect microclimate conditions. This study evaluated both the efficiency of Low Impact Development (LID) facilities in treating NPS pollutant loads as well as the unit pollutant loads (UPL) generated in various urban features (such as parking lots and highways). This investigation also looked at how LID technology helped to alleviate Urban Heat Island (UHI) conditions. As compared to the typical unit pollutant loads in South Korea, the unit pollutant loads at Kongju National University were relatively low, because of no classes, limited vehicular transmission, and low anthropogenic activities during vacation. After receiving treatment from the LID facilities, the effluent pollutant loads were significantly decreased. The sedimentation in filtration mechanisms considerably reduced the pollutant fractions in the influent. Additionally, it was shown that LID facilities' mean surface temperatures are up to 7.2℃ lower than the nearby paved environment, demonstrating the LID systems reducing the UHI impact on an urban area.

Variations of the Pollutant Concentration by Explosive Demolition of a Building and Management Plan of Non-point Source Pollution (구조물의 해체 공정별 오염농도 변화 및 비점오염원 관리 방안)

  • Chu, Kyoung-Hoon;Yoo, Sung-Soo;Kim, Hyo-Jin;Lee, Kyoung-Hee;Ko, Kwang-Baik
    • Explosives and Blasting
    • /
    • v.29 no.1
    • /
    • pp.17-26
    • /
    • 2011
  • In this study, the pollutants contained in water and soil samples taken from the explosive demolition site were examined to investigate the effects on environment, and management plan of non-point source pollution in the demolition site was suggested through characterizing the movement of the pollutant with time. As results, pH value of the water and soil samples after the demolition work was 8.5~9.3 which exceeds the Korean environmental criterion of water and soil range due to calcium hydroxide compounds in the concrete. The concentration level of heavy metals caused by the explosive demolition doesn't exceed the environmental criterion of water and soil doesn't exceed the environmental criterion of water and soil quality, and the influence of water and soil pollution on the environment was not considered. The concentration of the heavy metals was analyzed and that of Cr, Cu, Zn and Hg among the heavy metals increased after the drilling and explosive demolition. This says that concentration of the heavy metals during explosive demolition works needs to be monitored. The most pollutants with time or rain dilution into the demolition site decreased and this means that the pollutants caused by the explosive demolition might have influenced to vicinity of the demolition sites as non-point pollution.