• Title/Summary/Keyword: Non-Heating Type

Search Result 77, Processing Time 0.037 seconds

Study on Optimization for Heating System of Sequential Feed-Type Mobile Smart Device Cover Glass Molding Machine (모바일 스마트 기기 덮개 유리 순차이송형 성형기기의 가열시스템 최적화에 관한 연구)

  • Lee, Jun Kyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.75-80
    • /
    • 2015
  • Nowadays, flat-shaped cover glass is widely used for mobile devices. However, for its good design and convenience of use, curved cover glass has been demanded. Thus, many companies have tried to produce curved cover glass through the shaving technique, but the production efficiency is very low. Therefore, the molding technique has been adopted to increase the efficiency for the curved-glass production system. For a glass-molding system, several heating blocks are installed, and the flat cover glass is sequentially heated and molded. The production time for the cover glass is very different depending on the heating conditions; thus, the prediction of the production time for different heating conditions should be needed. Therefore, in this study, the computations were performed with different heating conditions (uniform and non-uniform) in the present cover glass-molding machine. For uniform and non-uniform heating conditions, the simple correlation between the heating time and the heater capacity and the heating time to achieve higher durability can be suggested, respectively.

A Study on the Heated Edible Oils( I ) -Flow Properties of Soybean, Rapeseed, Rice bran, Corn and Perilla Oils- (가열식용유(加熱食用油)에 관(關)한 연구(硏究) ( I ) -대두(大豆), 채종(菜種), 미당(米糖), 옥수수, 들깨유(油) 유동성(流動性) 관(關)해서-)

  • Kim, Eun-Ae;Shin, Kab-Choul;Kim, Haeng-Ja;Park, Jae-Ok
    • Journal of Nutrition and Health
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 1977
  • Flow properties of heated edible oils, such as soybean, rapeseed, rice bran, corn and perilla oils, were measured with Maron-Belner type capillary viscometer. These oils were heated at $180{\pm}5^{\circ}C$ (general cooking temperature) for $5{\sim}20$ hours except soybean oils ($5{\sim}40$ hours). Fluidities of these heated oils except rice bran oil were decreased according to heating time and decreasing ratio of fluidity was outstanding after 15 hour heating in corn oil and 20 hours heating in soybean and perilla oils. All the oils examined in this experiments except rice bran oil showed non-Newtonian motion after 15 hour hinting at high shear stress and Newtonian motion at less than 10 hour heating. In the soybean oil non-Newtonian flow property was outstanding after 30 hour heating at $180{\pm}5^{\circ}C$. Rice bran oil exhibit characteristic flow property, that is, non heated rice bran oil has lowest fluidity but heated one has highest fluidity compared to other oils examined in this experiment. Change of fluidity with extension of heating time was not detected and non heated rice bran oil showed non-Newtonian motion.

  • PDF

Evaluation of Volatile Compounds Isolated from Pork Loin (Longissimus dorsi) as Affected by Fiber Type of Solid-phase Microextraction (SPME), Preheating and Storage Time

  • Park, Sung-Yong;Yoon, Young-Mo;Schilling, M. Wes;Chin, Koo-Bok
    • Food Science of Animal Resources
    • /
    • v.29 no.5
    • /
    • pp.579-589
    • /
    • 2009
  • This study was conducted to investigate the effects of heating, fiber type used in solid-phase microextraction (SPME, two phase vs three phase) and storage time on the volatile compounds of porcine M. longissimus dorsi (LD). Volatile compounds were measured using a gas chromatography and mass spectrometry (GC/MS) with a quadrupole mass analyzer. Among the volatile compounds identified, aldehydes (49.33%), alcohols (24.63%) and ketones (9.85%) were higher in pre-heated loins ($100^{\circ}C$/30 min), whereas, alcohols (34.33%), hydrocarbons (22.84%) and ketones (16.88%) were higher in non-heated loins. Heating of loins induced the formation of various volatile compounds such as aldehydes (hexanal) and alcohols. The total contents of hydrocarbons, alcohols, and carboxylic acids were higher in two phase fibers, whereas those of esters tended to be higher in three-phase fibers (p<0.05). Most volatile compounds increased (p<0.05) with increased storage time. Thus, the analysis of volatile compounds were affected by the fiber type, while heating and refrigerated storage of pork M. longissimus dorsi increased the volatile compounds derived from lipid oxidation and amino acid catabolism, respectively.

Development of Heating Roller Monitoring System for Lamination (라미네이션을 위한 히팅롤러 모니터링 시스템 개발)

  • Oh, Jae-Jun;Choi, Woon-Shik;Choi, Seong-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.677-682
    • /
    • 2017
  • Lamination is used extensively in various industries. The type of lamination applied to the material depends on the precision level required, which varies for materials needed for everyday use, materials used in high-tech industries, and processes employed to fabricate finished products. Especially in hot lamination, the distribution of the surface temperature of the heating roller is very important to avoid the generation of internal bubbles and ensure flatness of the attached materials, and thus maintain a good standard of quality and productivity. In this study, we have developed a system to monitor the surface temperature of the heating rollerby applying a heterogeneous controller and a non - contact temperature sensor. This monitoring system accurately measures the surface temperature of the heating roller and applies the RS485 MODBUS communication method for easy expansion. Using this system, a laminated prototype was fabricated, and its efficacy for non-contact temperature sensor calibration, Ethernet IP communication, stoppage of the heating roller, and determination of temperature distribution with rotation was examined for its potential usage in industries.

Prediction of mechanical properties of limestone concrete after high temperature exposure with artificial neural networks

  • Blumauer, Urska;Hozjan, Tomaz;Trtnik, Gregor
    • Advances in concrete construction
    • /
    • v.10 no.3
    • /
    • pp.247-256
    • /
    • 2020
  • In this paper the possibility of using different regression models to predict the mechanical properties of limestone concrete after exposure to high temperatures, based on the results of non-destructive techniques, that could be easily used in-situ, is discussed. Extensive experimental work was carried out on limestone concrete mixtures, that differed in the water to cement (w/c) ratio, the type of cement and the quantity of superplasticizer added. After standard curing, the specimens were exposed to various high temperature levels, i.e., 200℃, 400℃, 600℃ or 800℃. Before heating, the reference mechanical properties of the concrete were determined at ambient temperature. After the heating process, the specimens were cooled naturally to ambient temperature and tested using non-destructive techniques. Among the mechanical properties of the specimens after heating, known also as the residual mechanical properties, the residual modulus of elasticity, compressive and flexural strengths were determined. The results show that residual modulus of elasticity, compressive and flexural strengths can be reliably predicted using an artificial neural network approach based on ultrasonic pulse velocity, residual surface strength, some mixture parameters and maximal temperature reached in concrete during heating.

Experimental Study on Bio-signal Characteristics of Stuckyi during Heating (스투키의 가열에 의한 생체 신호 변화 특성에 대한 실험 연구)

  • Nam, Dahyun;Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.6 no.1
    • /
    • pp.7-11
    • /
    • 2016
  • An experiment was performed to show the bio-signal characteristics of the Stuckyi when was heated. To measure the bio-signal of the plant, this study used the electrode with copper(+) and constantan(-). The electrode was directly inserted into the Stuckyi stems. And used T-type thermocouple to measure the inside temperature of the Stuckyi. During the experiments, room temperature also measured with T-type thermocouple. Heating was made with hair dryer periodically that 3 times turned on for heating 5 min and off for non-heating 25 min. Under the situation, the responses of the Stuckyi including voltage potential and inside temperature were measured using data logger(HP-34970A) according to the distances(15cm, 30cm, 45cm) between hair dryer and the plant. Through the experiments, We knew that the inside temperature has similar level and behavior with the room temperature at normal state. And during heating period, the inside temperature and the potential were also simultaneously increased sharply. From the experiments, we revealed that the measuring system of bio-signal of the plant being proposed in this study can be useful to show the Characteristics of the plants.

A Consideration of the PWM Cycloconverter with a Resonant Circuit for Induction Heating (공진회로를 이용한 유도가열용 PWM 사이크로콘버터에 대한 고찰)

  • Kim, Hyun-Jung;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.509-511
    • /
    • 1994
  • Cycloconverters can be classified into two types by the main circuit configuration. One is the non- circulating current type required the dead time the other is circulating current type which has the circulating current reactors. The switching devices were highly stressed by the load voltages during dead time on non-circulating current type operation and the circulating currents on circulating current type operation. The overcome those problems, this paper proposes the switching patterns for the partial and the non circulation current type. The PWM methods, which are saw wave comparing method and load current integrating value comparing method, are presented.

  • PDF

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

A Study on the Bonding Process of Carbon Fiber-Thermoplastic Composite Using Induction Heating Technology (유도가열 기술을 이용한 탄소섬유-열가소성 복합재의 접합 공정에 관한 연구)

  • Kang, Chang-Soo;Yoo, Myeong-Han;Seo, Min-Kang;Choi, Bo-Kyung
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.421-425
    • /
    • 2021
  • In this study, thermoplastic composites were manufactured using a thermoplastic resin (PEEK) with the same melting temperature and a highly heat-resistant carbon UD tapes with different carbon fibers (Type A, Type B). And the bonding characteristics and mechanical characteristics of each of the two produced thermoplastic composites by induction heating welding were examined. The bonding characteristics and mechanical characteristics of the thermoplastic composites were performed using C-Scan and B-Scan, which is a non-destructive inspection, and the single lap shear test, respectively. The temperature of the carbon composites surface was monitored using a thermal image camera.

An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes (모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.