• Title/Summary/Keyword: Non-Contact Test

Search Result 354, Processing Time 0.033 seconds

A Study on the Contact Allergic Skin Sensitization of 0.3% DA-5018 Cream, a Non-narcotic Analgesic Agent, with Guinea Pig Maximization Test (Guinea Pig Maximization Test를 이용한 0.3% DA-5018 cream의 접촉성 앨러지에 대한 연구)

  • 강경구;김동환;백남기;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • v.4 no.4
    • /
    • pp.391-397
    • /
    • 1996
  • The aim of this study was to assess the allergenic potential of 0.3% DA-5018 cream, a non-narcotic analgesic agent, using a guinea pig maximization test. Five male and female guinea pigs in the experimental group were sensitized in two steps. First, ,0.3% DA-5018 cream was injected intradermally, and 7 days later, the material was applied topically. After another 2 weeks test material was applied, the skin response was evaluated by visual observation. Five male and female guinea pigs served as cream base group, negative(ultreated) group or positive (2,4-dinitrochlorobenzene, DNCB) group, respectively. 0.3% DA-5018 cream provoked slight erythema in 1 out of 5 cases in male and female guinea pigs sensitized with 0.3% DA-5018 cream or cream base. The animals challenged with cream base also showed slight erythema in 1/5 female guinea pig sensitized with 0.3% 3A-5018 cream or 2/5 male guinea pjgs sensitized with cream base, respectively. Histologically, however, no indication of skin sensitization was observed in all of these cases. The positive control group was sensitized with 0.1% DNCB suspended in olive oil and challenged with 0.01% and 0.1% DNCB ointment, all the animal showed remarkable skin reactions and obvious skin sensitization reactions in a dose dependent manner. From the challenge test it was evident that 0.3% DA-5018 cream did not elicit positive skin reaction interpreted as delayed hypersensitivity reactions, compared with cream base or untreated control group. These findings indicate that allergenic side effects by 0.3% DA-5018 cream is not likely in the clinical use.

  • PDF

Development of Non-Contact Fiber Jumper Cord and Evaluation of Light Transmission Performance (비접촉식 광 점퍼 코드 개발 및 광 전송 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.399-405
    • /
    • 2016
  • Recently, fiber optic sensors, which have many advantages are being applied in various fields by replacing conventional electric sensors. To transmit the light signals between an interrogator and a sensor head, optical components such as an optical adaptor and optical jumper cords are generally used. When signals are transmitted using an adaptor, the end surface of each jumper cord is faced together. If alien substances exist on the core surface of an optical fiber, those can cause light transmission loss and signal disappearance. For this reason, non-contact fiber jumper cords are developed to overcome the problems that require continual attention. The light transmission performance of non-contact fiber jumper cords are also evaluated. From the test results, conventional fiber jumper cords are unable to transmit the signals over 2 mm cavity between the ends of both cords. Otherwise, non-contact fiber jumper cords can transmit the signals with stability up to the cavity of 7 mm though they have more transmission loss than the conventional ones. Consequently, non-contact fiber jumper cords that have better signal stability than conventional ones in environments are highly recommended in field applications, especially if they play a role as a cable for signal transmission between fiber optic sensors.

Gait Asymmetry in Children with Down Syndrome (다운증후군 아동들의 보행 비대칭성 연구)

  • Lim, Bee-Oh;Han, Dong-Ki;Seo, Jung-Suk;Eun, Seon-Deok;Kwon, Young-Hoo
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.145-151
    • /
    • 2006
  • A large interindividual variability and some abnormally kinematic patterns at the lower extremity were the main features of the gait in children with Down syndrome. The purposes of this study were to investigate the gait asymmetry and biomechanical difference between dominant leg and non dominant leg in children with Down syndrome. Seven boys with Down Syndrome(age: $120{\pm}0.9yrs$, weight $34.4{\pm}8.4kg$, leg length: $68.7{\pm}5.0cm$) participated in this study. A 10.0 m ${\times}$ 1.3 m walkway with a firm dark surface was built and used for data collection. Three-dimensional motion analyses were performed to obtain the joint angles and range of motions. The vertical ground reaction forces(%BW) and impulses($%BW{\cdot}s$) were measured by two force plates embedded in the walkway. Asymmetry indices between the legs were computed for all variables. After decision the dominant leg and the non dominant leg with max hip abduction angle, paired samples t-test was employed for selected kinematic and ground reaction force variables to analyze the differences between the dominant leg and the non dominant leg. The max hip abduction angle during the swing phase showed most asymmetry, while the knee flexion angle at initial contact showed most symmetry in walking and running. The dominant leg showed more excessive abduction of hip in the swing phase and more flat-footed contact than the non dominant leg. Vertical peak force in running showed more larger than those of in walking, however, vertical impulse showed more small than walking due to decrease of support time. In conclusion, the foot of dominant leg contact more carefully than those of non dominant leg. And also, there are no significant difference between the dominant leg and the non dominant leg in kinematic variables and ground reaction force due to large interindividual variability.

An Experimental Evaluation on Vibration Serviceability of Existing Bridge by Non-contact Vibration Measurement Method (비부착식 진동측정방법에 의한 공용중 교량의 진동사용성에 대한 실험적 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae;Lee, Kyu-Wan;Jun, Jin-Taek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.254-262
    • /
    • 2010
  • In order to evaluate vibration serviceability by means of non-contact vibration meter, serviceability of existing bridge were experimentally evaluated by using laser vibration meter. Test results were analyzed and compared with evaluation results acquired by using accelerometer and LVDT. To testify accuracy of laser vibration meter measured natural frequency were compared with that acquired by using accelerometer. According to test and comparison results it is showed that serviceability can be evaluated properly enough from the tolerance curve of Reiher-Meister for the estimated acceleration that can be calculated by the numerical differentiation of measured velocity. But because of cumulative numerical error occurred during integration of measured velocity in the time domain serviceability grade could be different from the result acquired by LVDT.

Color Inspection System for Plasma Display Panel by Using Area Camera (영역 카메라를 이용한 플라즈마 디스플레이의 컬러출력 검사 시스템)

  • 김우섭;도현철;진성일
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.1763-1766
    • /
    • 2003
  • This paper proposes a non-contact color inspection system for plasma display panel (PDP). The red, green, and blue test pattern images are acquired by using the area color CCD camera at the various distance from the PDP. The RGB values are obtained from the region of interest (ROI) which are extracted by applying the image processing to the test pattern image. Finally, the CIE xy and u'v' chromaticity coordinates of the test pattern images according to the distance are acquired from the RGB color coordinates.

  • PDF

Security and Trust on Non-Contact Financial Transaction (금융보안과 신뢰가 비대면 금융거래에 미치는 영향)

  • John, Yong-Jean
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.147-154
    • /
    • 2021
  • The pandemic age came to us after the COVID19 broke out in the early of 2020, which resulted in many changes in our everyday life. One of the changes is non-contact transactions in economic activities, especially contact-free financial transactions are ever-increasing activities in the pandemic age. In non-contact financial transactions, security and trust are important issues that users are concerned about the most. So the paper examines how security and trust have effects on the attitudes of bank customers who use mobile banking applications on their smartphones. The study conducted factor ananlysis to extract research constructs using survey data gathered during Nobember of 2020 through February of 2021 across the nation. After extracting the constructs, the study checked validity, sampling adequacy, and internal reliability with KMO, Bartlett's test, and Crombach Alpha respectively. To make sure the purpose of the study, I do regression analysis. All factors of attitude had impacts on willingness on both of transactions and purchasing financial products. The results could give guidelines banks which want to attract more customers in open-banking environment through ever-more secure and trusty mobile banking application.

Utilization of the Unlinked Case Proportion to Control COVID-19: A Focus on the Non-pharmaceutical Interventional Policies of the Korea and Japan

  • Yeri Jeong;Sanggu Kang;Boeun Kim;Yong Jin Gil;Seung-sik Hwang;Sung-il Cho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.4
    • /
    • pp.377-383
    • /
    • 2023
  • Objectives: Korea and Japan have managed the spread of coronavirus disease 2019 (COVID-19) using markedly different policies, referred to as the "3T" and "3C" strategies, respectively. This study examined these differences to assess the roles of active testing and contact tracing as non-pharmaceutical interventions (NPIs). We compared the proportion of unlinked cases (UCs) and test positivity rate (TPR) as indicators of tracing and testing capacities. Methods: We outlined the evolution of NPI policies and investigated temporal trends in their correlations with UCs, confirmed cases, and TPR prior to the Omicron peak. Spearman correlation coefficients were reported between the proportion of UCs, confirmed cases, and TPR. The Fisher r-to-z transformation was employed to examine the significance of differences between correlation coefficients. Results: The proportion of UCs was significantly correlated with confirmed cases (r=0.995, p<0.001) and TPR (r=0.659, p<0.001) in Korea and with confirmed cases (r=0.437, p<0.001) and TPR (r=0.429, p<0.001) in Japan. The Fisher r-to-z test revealed significant differences in correlation coefficients between the proportion of UCs and confirmed cases (z=16.07, p<0.001) and between the proportion of UCs and TPR (z=2.12, p=0.034) in Korea and Japan. Conclusions: Higher UCs were associated with increases in confirmed cases and TPR, indicating the importance of combining testing and contact tracing in controlling COVID-19. The implementation of stricter policies led to stronger correlations between these indicators. The proportion of UCs and TPR effectively indicated the effectiveness of NPIs. If the proportion of UCs shows an upward trend, more testing and contact tracing may be required.

Structural Analysis of S-cam Brake Shoe for Commercial Vehicle by FEM (FEM을 이용한 상용차용 S-cam 브레이크슈의 구조해석)

  • Suh, Chang-Min;Jee, Hyun-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.69-77
    • /
    • 2009
  • Structural analysis of a brake shoe for commercial vehicle was performed using finite element method. Since the strength of a brake shoe is affected by the magnitude and distribution shape of the contact pressure with the drum, the contact pressure between the shoe friction material and drum was calculated using a 2-Dimensional non-linear contact analysis in a state. And the brake was actuated by input air pressure and the drum of it was calculated both stationary and dynamic based on forced torque applied to the drum during the static state analysis. The results of the above analysis were then used as the load boundary conditions for a 3-Dimensional shoe model analysis to determine the maximum strain on the shoes. In the analysis model, the values of tensile test were used for the material properties of the brake shoes and drum, while the values of compression test were used for the friction material. We assumed it as linear variation, even though the properties of friction material were actually non-linear. The experiments were carried out under the same analysis conditions used for fatigue test and under the same brake system which equipped with a brake drum based on the actual axle state in a vehicle. The strains were measured at the same locations where the analysis was performed on the shoes. The obtained results of the experiment matched well with those from the analysis. Consequently, the model used in this study was able to determine the stress at the maximum air pressure at the braking system, thereby a modified shoe model in facilitating was satisfied with the required endurance strength in the vehicle.

Wear behavior of SM55C steel by rolling contact (구름접촉에 의한 SM55C의 마멸 거동)

  • Park, Beom-Su;Chae, Young-Hun;Kim, Seock-Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.240-247
    • /
    • 2002
  • The rolling wear behavior of SM55C is investigated under lubrication. This is a comparative tribological behavior of heat treatment effect for SM55C. Rolling wear test method is used for Ball-on-disk type. Specimens can be classified into two main groups: as-annealing and non-annealing. As result of wear behavior, flanking initial time of non-annealing specimen keep at retard but it have not under high normal load. One of the notable features of annealing specimen is steady flanking initial time for a normal load in this experiment. Failure mechanism of SM55C is due to the fatigue wear such like flanking, pitting etc.. Flanking leads to abruptly fracture of worn surface. Fracture mechanism has a connection with normal load and polishing direction of specimens.

  • PDF

Development of Non-contact Torque Sensor (비접촉 토오크센서의 개발(I))

  • Son, Dae-Rak;Im, Sun-Jae;Kim, Chang-Seok;Nam, Gung-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.29-33
    • /
    • 1992
  • A non-contact torque sensor was developed using amorphous alloy. The change of maixmum magnetic induction of C0-based amorphous alloy under the tensile and compressive stress was proportional to applied torque. For the construction of the torque sensor, a glass fiber reinforced-epoxy rod was used as shaft. The amorphous strips were attached on the epoxy shaft in the direction of $+45^{\circ}$and $-45^{\circ}$. The magnetizing coil and 2 sensing coil was installed. The static and dynamic test was carried out. The linearity and sensor hysteresis of the torque sensor was less than 1%.

  • PDF