• Title/Summary/Keyword: Noise-Level Measurement

Search Result 553, Processing Time 0.029 seconds

A Study on the Evaluation Unit of a Military Aircraft Noise (군용항공기 소음평가 단위에 관한 연구)

  • Lee, Jun-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.550-557
    • /
    • 2005
  • Korean 'Law of Aviation' and 'Test Method of Measuring Noise and Vibration' designate to use WECPNL metric based on $L_{max}$ measurement for the accessment of aircraft noise in Korea. However, time duration of noise event can not be considered in $L_{max}$ metric in principle, compensation on the duration has been utilized. A study was done recently to evaluate appropriate duration compensation for the accessment of military aircraft noise under current metric of WECPNL and $L_{max}$. This study was carried out to evaluate what metric is the most appropriate to express aircraft noise including time duration of single noise event, computing and comparing noise exposure with 1 second noise measurement data of military aircraft in $L_{max}$, $L_{Aeq,\;T}$ and SEL. This study shows SEL is the most appropriate noise metric for the evaluation of noise exposure with time duration such as aircraft noise without compensation. It is suggested to use SEL noise metric instead of $L_{max}$ noise metric with duration compensation for the aircraft noise accessment either military aircraft or civilian aircraft.

An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test (실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구)

  • Kim, Hang;Park, Hyeon Ku;Ku, Hee Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.

Noise Measurement Method Development and Correlation Analysis According to Measurement Location of Small Unmanned Robot (소형 무인 로봇의 소음 측정법 개발 및 측정 장소에 따른 상관성 분석)

  • Ok, Jinkyu;Park, Eunjoo;Park, Minsu;Lee, Myungchun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.633-638
    • /
    • 2017
  • The small unmanned robot developed in this paper can perform tasks such as surveillance and reconnaissance in the battle field. The noise generated during the operation of the robot may expose the operation area. Therefore, in this study, we developed a method to quantitatively measure the noise of the developed small unmanned ground robot. The criteria for noise measurement in indoor and outdoor are presented. It was used for statistical verification method to verify the reliability of the developed noise measurement method. The noise was measured at different places, and the correlation was analyzed. Thus, we proposed a method to predict the noise level in the operation area where the robot is operated by the noise test data measured during the development process.

A Study on the Model Test for the Twin Propeller Cavitation Noise (쌍축선 추진기 캐비테이션 소음 모형시험 연구)

  • Park, Cheolsoo;Kim, Gun-Do;Yim, Geun-Tae;Park, Young-Ha;Jang, Hyun-Gil;Jang, Young Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • The experimental results of the model tests for the twin propeller cavitation noise are presented. The model test was carried out by means of procedure of noise measurement followed by the signal processing and full-scale extrapolation. In order to convert the measured sound pressure level into the sound source level, transfer function measurements for three conditions were performed according to the combination of locations and number of virtual sources. White noise and LFM signal were used as a source signals to examine the influence of the input signal. For the twin propellers, 5 transfer functions were defined and the results were discussed. Cavitation noise measurement tests were performed similarly to the transfer function measurement test. Noise source localization analysis was performed to confirm the test effectiveness. It was confirmed that the source level of the twin propeller can be estimated reliably by using transfer function corrections. Finally, the model test results were converted into full-scale by applying the ITTC '87 model-ship scaling raw, and the validity of the model test was confirmed by comparison with the full-scale measurement result.

Evaluation on Noise Level of One-Room Type Multi-Family Housing Around Campus (대학주변 원룸형 다가구주택의 소음측정평가)

  • Choi, Yoon-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.95-100
    • /
    • 2003
  • The purpose of this study is to evaluate the noise environment of one-room type multi-family housing around the campus. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the 26th${\sim}$28th of November 2002. The results are as follows. 1) Outdoor noise levels of 6 subject buildings were distributed 52.8${\sim}$65.3dB(A) and were inappropriate to the standard for environmental noise, 55dB(A). 2) Indoor noise level of 6 subject house units were measured 27.5${\sim}$63.5dB(A). These values were higher than the indoor noise standard (40dB(A)) except subject house D(average 37.6dB(A)). 3) It was found that the differences of indoor noise levels between subject house units were caused by resident's living factor, characteristics of window, and existence of balcony.

  • PDF

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

A Study on Intrinsic Noise of Capacitively Coupled Active Electrode (용량성 결합 능동 전극의 내부 잡음 분석)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily Life. This study is the first step to reducing the large background noise appearing in indirect-contact ECG. This study built the thermal noise model of capacitively coupled active electrode which is used in indirect-contact ECG. The results show that the level of thermal noise estimated by the thermal noise model is much the same as that of actual background noise for the capacitively coupled active electrode alone. By applying the actual electrical properties of a sample cotton cloth to the thermal noise model, the theoretical level of thermal noise in the indirect-contact ECG was estimated. The results also show that the level of op-amp's intrinsic noise is so small that it can be negligible in comparison with thermal noise of resistors. The relationship between the level of thermal noise and the resistance of the bias resistor was derived, and it is the base for the further study how to choice the optimal resistance for the bias resistor.

Circular Diamond Saw with Low Noise Shank (원형 다이아몬드톱의 저소음 생크)

  • 윤승원;지원호;우종혁
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.729-732
    • /
    • 2004
  • An experimental and numerical approach has been carried out for to see the noise characteristics of a circular diamond saw. The noise level measurement result for the several kinds of shanks shows us that the noise level reduction in high frequency range could be an effective way to control the noise problem. Sandwich type shank whose center part is laminated with a low Young‘s modulus material greatly reduces the noise level. The noise level for the shank where several curve shaped slits are provided in the circumferential direction is reduced considerably too. The response spectrum analysis by the FEM shows us to be an alternative for predicting the noise characteristics of the shank.

  • PDF

Study on the Acceptance Level for Damage due to Underwater Noise from the Case Study of Field Measurement at Marphysa sanguinea Farm (바위갯지렁이 양식장 인접지역 계측 사례를 포함한 수중소음 피해인정기준에서 배경소음과의 차에 대한 문제점)

  • Choi, Tae-Hong;Kim, Jae-Woong;Ko, Chin-Surk
    • Explosives and Blasting
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2017
  • It is very difficult to clearly define the damages caused by blasting-induced noise and vibration, because the damages depend on, besides the level of noise and vibration, the response of the object, environmental conditions, subjective feeling, and mental condition. Especially, it is more difficult when the fish is concerned, because that experimental approach is not easy and that we lack of the reasonable criterion for the acceptance level of noise and vibration. In Korea, the acceptance level for damage due to underwater noise is 140 dB re $1{\mu}Pa$, and the difference from the underwater background sound level is defined as more than 20 dB re $1{\mu}Pa$. It is however, appropriate for continuous noise not for transient sound. The authors compared the relationship between vibration velocity and underwater noise measured from the test blasting around Marphysa sanguinea farm. This paper presents the measurement results and suggestions the acceptance level for damage due to underwater noise from explosive blasting.

Analysis of Vehicle Noise Effect by Microphone Position and Road Geometry (도로 기하구조에 따른 차량 Microphone 위치별 소음 영향 분석)

  • Moon, Hak Ryong;Han, Dae Cheol;Kang, Won Pyoung
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSES: The purpose of study is to understand the characteristic of driving noise from the front and rear tire for effective active noise cancellation application. METHODS : As literature review, noise measurement methods were reviewed. Noise measurement conducted at three kind of section by road slope using CPX(Close Proximity Method). Noise data was compared by total sound pressure level and 1/3 octave band frequency sound pressure level. Also, each section was compared by T-test using SPSS. RESULTS : In the case of the uphill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low and high frequency band. In the case of high slope section of Sangsaek-Ri, the sound pressure level of the front tire was higher than that of the rear tire in high frequency. Also, in the case of the downhill section, it was shown that the sound pressure level of the front tire at Sugwang-Ri and Sinchon-RI sections was higher than that of the rear tire in low frequency band. However, the sound pressure levels of both the front and rear tires were approximately the same in the high slope section of Sangsaek-Ri. The result of T-test showed that total sound pressures of the front and rear tires were not different from each other in the case of high slope and high speed. CONCLUSIONS: Road slope was not an important variable for effective active noise cancellation.