• Title/Summary/Keyword: Noise measures

Search Result 465, Processing Time 0.031 seconds

A 10b 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS Pipeline ADC with Various Circuit Sharing Schemes (다양한 회로 공유기법을 사용하는 10비트 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS Pipeline ADC)

  • Yoon, Kun-Yong;Lee, Se-Won;Choi, Min-Ho;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.53-63
    • /
    • 2009
  • This work proposes a 10b 100MS/s 27.2mW $0.8mm^2$ 0.18um CMOS ADC for WLAN such as an IEEE 802.11n standard. The proposed ADC employs a three-stage pipeline architecture and minimizes power consumption and chip area by sharing as many circuits as possible. Two multiplying DACs share a single amplifier without MOS switches connected in series while the shared amplifier does not show a conventional memory effect. All three flash ADCs use only one resistor ladder while the second and third flash ADCs share all pre-amps to further reduce power consumption and chip area. The interpolation circuit employed in the flash ADCs halves the required number of pre-amps and an input-output isolated dynamic latch reduces the increased kickback noise caused by the pre-amp sharing. The prototype ADC implemented in a 0.18um n-well 1P6M CMOS process shows the DNL and INL within 0.83LSB and 1.52LSB at 10b, respectively. The ADC measures an SNDR of 52.1dB and an SFDR of 67.6dB at a sampling rate of 100MS/s. The ADC with an active die area of $0.8mm^2$ consumes 27.2mW at 1.8V and 100MS/s.

Evaluation of factors affecting sensory neural hearing loss (감각신경성 청력손실에 영향을 미치는 제 요인에 관한 연구)

  • Hong, Seong-Chul;Bae, Seong-Wook;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.249-264
    • /
    • 1998
  • Reports on a potential relationship between sensory neural hearing loss(SNHL) and cardiovascular or hematologic factor show that the results are controversial. A detailed analysis of risk factors in the development of SNHL was carried out in 3,050 non-noise exposed healthy worker. The mean hearing threshold of both ears at 500, 1000, 2000, 4000, 8000Hz was measured and the effect of age, possible cardiovascular risk factor and hematologic factor (blood viscosity and hemostatic factors) on SNHL were evaluated. first, each of these were associated with loss of hearing sensitivity when univariately and multivariatively analysed. In a multiple regression model, age, sex, body mass index, WBC and total cholesterol level were independently associated with the mean of hearing sensitivity decrease at 4000 and 8000Hz. Second, study subjects were divided into two group (normal vs SNHL) and we compare the possible risk between both groups, and analysed univariate and multivariative logistic model. In a multiple logistic regression model, age, sex, body mass index, WBC and total cholesterol level, total protein, platelet were independently associated with SNHL. Our results show that we have some reliable indices of susceptibility to SNHL using cardiovascular measures or biochemical factor, but future, more extensive studies are required.

  • PDF

Precise Detection of Buried Underground Utilities by Non-destructive Electromagnetic Survey (비파괴 전자탐사에 의한 지하 매설물의 정밀탐지)

  • Shon, Ho-Woong;Lee, Seung-Hee;Lee, Kang-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2002
  • To detect the position and depth of buried underground utilities, method of Ground Penetrating Radar(GPR) survey is the most commonly used. However, the skin-depth of GPR is very shallow, and in the places where subsurface materials are not homogeneous and are compose of clays and/or salts and gravels, GPR method has limitations in application and interpretation. The aim of this study is to overcome these limitations of GPR survey. For this purpose the site where the GPR survey is unsuccessful to detect the underground big pipes is selected, and soil tests were conducted to confirm the reason why GPR method was not applicable. Non-destructive high-frequency electromagnetic (HFEM) survey was newly developed and was applied in the study area to prove the effectiveness of this new technique. The frequency ranges $2kHz{\sim}4MHz$ and the skin depth is about 30m. The HFEM measures the electric field and magnetic field perpendicular to each other to get the impedance from which vertical electric resistivity distribution at the measured point can be deduced. By adopting the capacitive coupled electrodes, it can make the measuring time shorter, and can be applied to the places covered by asphalt an and/or concrete. In addition to the above mentioned advantages, noise due to high-voltage power line is much reduced by stacking the signals. As a result, the HFEM was successful in detecting the buried underground objects. Therefore this method is a promising new technique that can be applied in the lots of fields, such as geotechnical and archaeological surveys.

A Study on Standard Ocean Lighted Buoy Type System for Real-time Ocean Meteorological Observation (실시간 해양관측을 위한 표준형 등부표용 시스템 연구)

  • Park, Sanghyun;Park, Yongpal;Bae, Dongjin;Kim, Jinsul;Park, Jongsu
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1739-1749
    • /
    • 2018
  • We propose a marine observation system using existing light buoys to observe various marine information of marine locations. Our proposed ocean observation system is composed of the existing standard light buoy type and can be easily connected to the light buoy. The proposed marine observation system measures the mean wave height, maximum wave height, mean wave height and water temperature measured in the ocean. Besides, it can measure the air pressure, temperature, wind speed and wind speed in real time. In order to measure important peaks in marine observations, 2200 peak data are collected for 10 minutes, and the collected data are subjected to spectral analysis to extract significant wave and wave period data. The developed system removes the noise by using the filter because the marine observation system attaches to the light buoy. We compare and analyze the measurement data of the existing proven floating marine observation system and the standard equivalent system developed. Also, it is proved that the data of the standard type backbone ocean observation system developed through the comparative experiment is similar to that of the existing ocean observation system.

Validity of Voice Handicap Index and Voice Analysis following Laryngeal Microsurgery for Benign Vocal Cord Lesions (양성 성대 질환 환자의 후두 미세 수술 전후 음성 장애 지수 및 음성 분석의 유용성)

  • Park, Young-Hak;Lee, Jeong-Hak;Joo, Young-Hoon;Park, Sung-Sin;Bang, Choong-Il;Kim, Min-Sik;Cho, Seung-Ho
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.23-27
    • /
    • 2005
  • Background and Objectives : Voice disorders can cause problems in patients with benign vocal cord lesions emotionally, physically, economically and functionally. Neither subjective nor objective voice examinations can evaluate such factors adequately. The Voice Handicap Index (VHI) subjectively evaluates voice disorders in terms of physical, functional, emotional factors and measures the patient's perception of the impact of voice disorder. The purpose of this study is to evaluate the usefulness of VHI in the patients with benign vocal cord lesions. Materials and Method : The authors evaluated 37 patients who experienced laryngeal microsurgery for benign vocal cord lesions from september 2003 to August 2004. The VHI was used to measure the postoperative changes of the patient's perception and acoustic analysis and aerodynamic tests were also done. Statistical analysis was done using paired t-test and Pearson's correlation. Results : The VHI scores showed statistically significant reductions postoperatively. In acoustic analysis, jitter and shimmer had statistically significant reductions after surgery but noise-to-harmonics ratio did not. A statistically significant change in the average MFR and MPT perioperatively was found. The relationship between VHI and acoustic, aerodynamic analysis attained statistical significance. Conclusion : The VHI is a useful assessment tool to monitor the patient's self-perception of voice change after the surgery of benign vocal cord lesions. The VHI measurement, when combined with acoustic and aerodynamic analyses, will be helpful in comparing functional outcomes after voice surgery.

  • PDF

Subhective Symptoms and Work-related Health Risk Factors in Korean Dental Laboratory Technicians (우리 나라 치과 기공사의 신체 자각 증상과 직업 관련 건강 위험 요인)

  • Kim, Woong-Chul;Lee, Se-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.89-112
    • /
    • 2000
  • Although dental laboratory technicians are prone to be exposed to various work-related health hazardous materials such as dusts, chemicals, etc., the prevalence and nature of work-related health problems of them have not been a matter of great concern in the field of occupational health service in Korea. The purpose of the present investigation was to describe a collected profile of subjective health symptoms and their attributable factors in Korean dental laboratory technicians. A questionnaire listing five groups of health symptoms and five health symptom-related factors was mailed to randomly selected 1,900 dental laboratory technicians. Among them, 1,344 dental laboratory technicians filled out the questionnaires and returnde them. Five groups of health symptoms included musculoskeletal symptom, dermal symptoms, respiratory symptoms, eys symptoms, and ear symptoms. Five health symptom-related factors were occupational environment-related health risk factors, work history, health related habits and status, use of personal protective equipment and general characteristics. Detailed parameters of health risk factors were work posture, vibration, and chemical or physical hazards such as dust, fume, vapor, solvent, light, and noise for occupational environment-related factors; work place, area, number of employees, work hours, career, work part, and work load for work history; Broca's index, hours of sleep, eating, smoking, alcohol, exercise, health examination, and self assessed health status for health habits and status; face masks, goggles, and so on for use of personal protective equipment, and; age, sex, marital status, and education for general characteristics. Before the start of main survey, a pilot survey was carried out for validity and reliability tests of the questionnaire. All the data obtained were coded and analyzed with PC/SAS 6.12 program. The prevalence of health symptoms was the highest in musculoskelton (87.3%), and followde by eyes (78.9%), respiratory organs (64.3%), ears (57.8%), and skin (52.2%) in descending order. Statistically significant risk factors by multiple logistic regression analyses were sex, health examination, self assessed health status, and hand/finger posture in musculoskeletal symptoms; sex, self assessed health status, career, acid gas, and hand contact with resin mixture in deraml symptoms; Broka's smoking, exercise, self assessed health status, and face mask in respiratory symptoms; sex, hours of sleep, self assessed health status, work hours, work load, plaster dust, inadequate lighting, and goggle in eys symptoms, and eating, smoking, self assessed health status, and work load in ear symptoms. With the above considerations in mind, prevalence of subjective symptoms among Korean dental laboratory technicians was relatively high, and they were attributable to most of the occupational environment-related factors, work history, use of personal protective equipment, health habits and status, and general characteristics. Particularly, it is suggested that health promotion programs for promoting self- assessed health status and smoking cessation, preventive measures for protection of the female technicians’health, and reducing work load be necessary, since those factors were associated with more than one subjective symptom.

  • PDF

HOW TO DEFINE CLEAN VEHICLES\ulcorner ENVIRONMENTAL IMPACT RATING OF VEHICLES

  • Mierlo, J.-Van;Vereecken, L.;Maggetto, G.;Favrel, V.;Meyer, S.;Hecq, W.
    • International Journal of Automotive Technology
    • /
    • v.4 no.2
    • /
    • pp.77-86
    • /
    • 2003
  • How to compare the environmental damage caused by vehicles with different foe]s and drive trains\ulcorner This paper describes a methodology to assess the environmental impact of vehicles, using different approaches, and evaluating their benefits and limitations. Rating systems are analysed as tools to compare the environmental impact of vehicles, allowing decision makers to dedicate their financial and non-financial policies and support measures in function of the ecological damage. The paper is based on the "Clean Vehicles" research project, commissioned by the Brussels Capital Region via the BIM-IBGE (Brussels Institute for the Conservation of the Environment) (Van Mierlo et at., 2001). The VriJe Universiteit Brussel (ETEC) and the universite Libre do Bruxelles (CEESE) have jointly carried out the workprogramme. The most important results of this project are illustrated in this paper. First an overview of environmental, economical and technical characteristics of the different alternative fuels and drive trains is given. Afterward the basic principles to identify the environmental impact of cars are described. An outline of the considered emissions and their environmental impact leads to the definition of the calculation method, named Ecoscore. A rather simple and pragmatic approach would be stating that all alternative fuelled vehicles (LPG, CNG, EV, HEV, etc.) can be considered as ′clean′. Another basic approach is considering as ′clean′ all vehicles satisfying a stringent omission regulation like EURO IV or EEV. Such approaches however don′t tell anything about the real environmental damage of the vehicles. In the paper we describe "how should the environmental impact of vehicles be defined\ulcorner", including parameters affecting the emissions of vehicles and their influence on human beings and on the environment and "how could it be defined \ulcorner", taking into account the availability of accurate and reliable data. We take into account different damages (acid rain, photochemical air pollution, global warming. noise, etc.) and their impacts on several receptors like human beings (e.g., cancer, respiratory diseases, etc), ecosystems, or buildings. The presented methodology is based on a kind of Life Cycle Assessment (LCA) in which the contribution of all emissions to a certain damage are considered (e.g. using Exposure-Response damage function). The emissions will include oil extraction, transportation refinery, electricity production, distribution, (Well-to-Wheel approach), as well as the emission due to the production, use and dismantling of the vehicle (Cradle-to-Grave approach). The different damages will be normalized to be able to make a comparison. Hence a reference value (determined by the reference vehicle chosen) will be defined as a target value (the normalized value will thus measure a kind of Distance to Target). The contribution of the different normalized damages to a single value "Ecoscore" will be based on a panel weighting method. Some examples of the calculation of the Ecoscore for different alternative fuels and drive trains will be calculated as an illustration of the methodology.

A comparative study of the acoustic characteristics of the vowel /a/ between children with spastic and dyskinetic cerebral palsy (경직형과 불수의운동형 뇌성마비아동의 /아/ 모음 음향학적 비교)

  • Jeong, Pil Yeon;Sim, Hyun Sub
    • Phonetics and Speech Sciences
    • /
    • v.12 no.1
    • /
    • pp.65-74
    • /
    • 2020
  • This study aims to compare the acoustic characteristics of vowel phonation in children with spastic and dyskinetic cerebral palsy (CP). Thirty-four children aged 4-12 years with CP participated in the study (spastic 26, dyskinetic 8). Voice samples for the acoustic analysis were extracted from a sustained vowel /a/. All acoustic measures were made using Praat. Group differences were compared by an independent t-test or Welch-Aspin test, if the equivalence assumption was not met. The results of this study are as follow. First, maximum phonation time(MPT) was significantly shorter for the dyskinetic CP than for the spastic CP. Second, shimmer percent was significantly increased in the dyskinetic CP than in the spastic CP. Lastly, there were no significant group differences in both the first formant and the second formant. These findings indicate that the dyskinetic CP has a poorer respiratory capacity and poorer laryngeal function than the spastic CP. On the other hand, both groups have a comparable ability to articulate the vowel /a/. The results of the present study help speech language pathologists identify the speech motor control ability of children with two types of CP (spastic and dyskinetic) and help to make an intervention plan associated with a specific type of CP.

The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light (녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정)

  • Chang, K.Y.;Ko, H.C.;Lee, J.J.;Yoon, Young Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

A Study on Variable Speed Limit Strategies in Freeway Work Zone Using Multi-Criteria Decision Making Process (다기준 의사결정기반 고속도로 공사구간 VSL전략에 관한 연구)

  • Park, Juneyoung;Oh, Cheol;Chang, Myungsoon
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.5
    • /
    • pp.3-15
    • /
    • 2013
  • The purpose of this study is to propose a methodology for operating variable speed limit (VSL) strategies in freeway work zones. A notable feature in this study is to incorporate a multi-criteria decision making process into deriving better VSL strategies. Decision criteria in this study include operational efficiency, safety, and environmental impacts. Travel speed, acceleration noise, and CO2 were used as performance measures for evaluating VSL strategies. A multi-criteria value function was developed through an analytical hierarchical process (AHP) for representing expert's knowledge. Then, a variety of VSL operations scenarios were investigated utilizing a microscopic traffic simulation suite, VISSIM. The proposed methodology would be useful in supporting more efficient, safer, and more environment-friendly traffic operations and control in freeway work zones.