• 제목/요약/키워드: Noise measurement

검색결과 3,210건 처리시간 0.029초

실내 인테리어 마감재에 따른 카페 재실자의 소음 환경 영향 분석 (Analysis of Noise Environment of Cafe Occupants According to Interior Finishing)

  • 이수한;윤희승;위승환;김수민
    • 한국가구학회지
    • /
    • 제28권4호
    • /
    • pp.355-361
    • /
    • 2017
  • Indoor noise environment is an important factor when it comes to occupants comfort, especially in cafe. Results of the survey, 33.9% of occupants were feel unpleasant and sensitive about noise environment. Noise in cafe fluctuate depending on the finishing of both wall and ceiling, volume of the room, and the number of occupants in the room. Therefore, the noise meter device was used for measurement of various under conditions. Also, the subjective assessment of occupant noise was conducted through questionnaires. When the interior finish was exposed concrete, the maximum value of the noise measurement was 66.6 dB and the minimum value was 63 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 5.43 and 4.96 point of 10 point of noise and echo, respectively. Otherwise, the interior finish was gypsum board, the maximum value of the noise measurement was 73.8 dB and the minimum value was 60.4 dB, respectively. Also, the result of subjective assessment of unpleasant noise were 3.88 and 3.95 point of 10 point of noise and echo, respectively. The results of the study showed that the noises and echoes in the cafes were lower than when did not.

바닥충격음 측정 및 차음 평가의 방향 (Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance)

  • 정정호;정영;서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

풍력발전시설 소음 측정 방법에 대한 고찰 (A Study on the Noise Measurement Method of Wind Power Facilities)

  • 이영진;이종태;민현경;권선용;이병찬
    • 환경영향평가
    • /
    • 제32권5호
    • /
    • pp.279-290
    • /
    • 2023
  • 최근 신재생에너지로서 바람의 힘을 이용한 풍력발전단지가 전국에 설치되면서 소음 문제가 대두되고 있다. 환경영향평가 및 사후환경영향평가에서도 풍력발전단지에 대한 배경소음 및 저주파소음을 측정하도록 하고 있으며, 특히 저주파소음은 환경부에서 2018년 공표한 저주파소음 관리 가이드라인에 따라 생활소음 측정방법을 준용하여 측정하도록 규정하고 있다. 고풍속에서 큰 소음을 발생시키는 풍력발전기의 특성상 고풍속에서 소음 측정이 이루어져야 하나 풍속이 증가할 경우 풍잡음이 증가하여 생활소음 및 저주파소음이 제대로 평가되지 못하는 문제가 발생되었다. 따라서 풍력발전기에서 발생되는 소음의 종류를 확인하고 풍잡음 등 풍력소음 측정시 고려되어야 할 사항을 확인하였다.

Modified Tikhonov regularization in model updating for damage identification

  • Wang, J.;Yang, Q.S.
    • Structural Engineering and Mechanics
    • /
    • 제44권5호
    • /
    • pp.585-600
    • /
    • 2012
  • This paper presents a Modified Tikhonov Regularization (MTR) method in model updating for damage identification with model errors and measurement noise influences consideration. The identification equation based on sensitivity approach from the dynamic responses is ill-conditioned and is usually solved with regularization method. When the structural system contains model errors and measurement noise, the identified results from Tikhonov Regularization (TR) method often diverge after several iterations. In the MTR method, new side conditions with limits on the identification of physical parameters allow for the presence of model errors and ensure the physical meanings of the identified parameters. Chebyshev polynomial is applied to approximate the acceleration response for moderation of measurement noise. The identified physical parameter can converge to a relative correct direction. A three-dimensional unsymmetrical frame structure with different scenarios is studied to illustrate the proposed method. Results revealed show that the proposed method has superior performance than TR Method when there are both model errors and measurement noise in the structure system.

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

저노이즈형 진동계측 앱을 통한 MEMS 센서의 계측성능분석 (The Analysis in Measurement Performance MEMS Sensor Through the Low-Noise Vibration Measurement APP)

  • 정영석;윤성원
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.93-100
    • /
    • 2017
  • With increasing number construction of high-rise building which has about 40 to 60 floors there have been many kinds of problem which related with usage from vibration. To predict response acceleration, it is important to assess correct natural frequency. However, due to the noise of MEMS sensor, it is difficult to measure dynamic characteristic such as natural frequency when measuring ambient vibration using MEMS sensor within cell phone. Therefore, a comparative analysis on vibration measuring applications was performed after measuring ambient vibration of 2 skyscrappers which have height between 133.5~244.3m that are located in Seoul and Observation tower using I-jishin APP with noise reduction function of MEMS sensor in order to verify the effectiveness of low noise type vibration measurement APP.

Reverberation 음장내 다수 소음원의 음파관을 이용한 소음 측정 방법 (The Noise Measurement Method of the Multi-Sound Source in Reverberation Field wiht Wave-Guide)

  • 이성태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.275-285
    • /
    • 1996
  • A noise measurement method of the multi-sound sources in a reverberation field with wave-guide is developed by experimental method. In the reverberation field, it is very hard to measure sound level or noise spectra of a certain sound source, when many sound sources generate noise simultaneously with a small space between them. Flexible wave-guide(tube) was used to measure noise level in a reverberation field. One end of the tube is attached to a sound source and the other end is closed with an anechoic terminal. Detailed method of the measurement and the source of error was considered as well.

  • PDF

호이스트 기어박스의 소음불량률 저감을 위한 실험적 연구 (An Experimental Study to Reduce the Fraction of Noise Defect of Hoist Gear Boxes)

  • 이희원;손병진;신용하
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1347-1354
    • /
    • 1994
  • This paper deals with the experimental research, including measurement and analysis and field survey, on the causes of occurring noise defective gear boxes in hoist production plant in order to reduce the fraction of their occurrence. In this reserch following investigations are performed : measurement and gear-boxes, examination of each machining process of production, measurement and analysis of dimensional accuracy of each part, comparative vibration test with exchanging inaccurate parts. From these investigations, it is found that the machining accuracy of pinion gear tooth thickness is the most sensitive factor of noise problem. By maintaining the tooth thickness error within 0.05 mm tolerance in the gear cutting process, the fraction of noise defective gear-boxes are greatly reduced to less than 2%, where the usual rate of it has been 20-50%.

Design of On-line Process Control with Variable Measurement Interval

  • Park, Changsoon
    • Journal of the Korean Statistical Society
    • /
    • 제29권3호
    • /
    • pp.319-336
    • /
    • 2000
  • A mixed model with a white noise process and an IMA(0,1,1) process is considered as a process model. It is assumed that the process is a white noise in the absence of a special cause and the process changes to an IMA(0,1,1) due to a special cause. One useful scheme in measuring the process level is to use the variable measurement interval (VMI) between measurement times according to the value of the previous chart statistic. The advantage of the VMI scheme is to measure the process level infrequently when in control to save the measurement cost and to measure frequently when out of control to save the off-target cost. This paper considers the VMI scheme in order to detect changes in the process model from a white noise to an IMA(0,1,1). The VMI scheme is shown to be effective compared to the standard fixed measurement interval (FMI) scheme in both statistical and economic contexts.

  • PDF

함정탑재장비 진동 측정불확도 추정 (Estimation of Uncertainty in Vibration Measurement of Shipboard Equipment)

  • 박성호;이경현;한형석
    • 한국소음진동공학회논문집
    • /
    • 제24권7호
    • /
    • pp.509-516
    • /
    • 2014
  • This paper proposes estimation model of uncertainty in vibration measurement of shipboard equipment and analyzes the result of uncertainty estimation. Vibration of shipboard equipments affects underwater radiated noise that is important performance related to stealth of the naval vessel. Acceptance testing for shipboard equipment is required to guarantee the stealth performance of naval vessel. In measuring, detailed uncertainty estimation is essential to improve measuring reliability. Acceptance testing result of structure-borne noise and vibration is used to analyze uncertainty in vibration measurement of shipboard equipment.