• Title/Summary/Keyword: Noise in ECG

Search Result 165, Processing Time 0.025 seconds

Noise Reduction and Characteristic Points Detectoin of ECG Signal using Wavelet Transforms (웨이브렛 변환을 이용한 ECG신호의 잡음제거와 특징점 검출)

  • 장두봉;이상민;신태민;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.1
    • /
    • pp.11-17
    • /
    • 1998
  • One of the main techniques for diagnosing heart disease is by examining the electrocardiogram(ECG). Many studies on detecting the QRS complex, p, and T waves have been performed because meaningful information is contained in these parameters. However, the earlier detecting techniques can not effectively extract those parameters from the ECG that is severely contaminated by noise source. In this paper, we performed the extracting parameters from and recovering the ECG signal using wavelets transform that has recently been applying to various fields.

  • PDF

Influence of Positional Changes of Arms and Legs to Electrocardiogram

  • Song, Joo-Eun;Song, Min-Ju;Kim, Ye-Sul;Yang, Ha-Nuel;Lee, Ye-Jin;Jung, Dongju
    • Biomedical Science Letters
    • /
    • v.24 no.1
    • /
    • pp.43-49
    • /
    • 2018
  • Electrocardiogram (ECG) is a widely used method to diagnose electrical activity of heart. Although it is a reliable and easy method, ECG could be interfered by electrical signals. One of the interfering signals is electromyogram (EMG) that is caused by muscle contraction in any parts of the body except heart. To avoid the EMG noise, an examinee is advised to be relaxed on supine position while measuring ECG. Sometimes, patients who can't put their arms and legs down on bed due to some reasons such as cast on arms or legs necessarily have the EMG noise. But detailed information about how much of the noise could be induced by positional change of arms and legs has not been reported. Here we examined the noise by analyzing ECG data from 14 candidates, 7 males and 7 females. The ECG data was obtained using the standard 12 lead ECG. EMG noise was induced by raising arms and legs at $90^{\circ}$, $60^{\circ}$ or $30^{\circ}$. Because arms are located close to the heart, noise by the raised arms was analyzed toward left or right arm separately. All of the examinees showed similar pattern of the EMG noise. EMG noise by positional change of left or right arm was clearly monitored in different limb leads. Change of leg positions induced the noise that was monitored in aVF of augmented leads and II and III of limb leads. There was a difference in degree of the noise between male and female examinees. In addition to the EMG noise, decrease of PR interval was monitored in particular positional changes, which was prominent in male examinees. These results will enlarge fundamental understanding about EMG noise in ECG.

Study on Noise Reduction of ECG Signal using Wavelets Transform (심전도신호의 잡음제거를 위한 웨이브렛변환의 적용에 관한 연구)

  • Chang, Doo-Bong;Lee, Sang-Min;Shin, Tae-Min;Lee, Gun-Ki
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.39-46
    • /
    • 1998
  • One of the main techniques for diagnosing heart disease is by examining the electrocardiogram(ECG). Many studies on detecting the QRS complex, P, and T waves have been performed because meaningful information is contained in these parameters. However, the earlier detection techniques can not effectively extract those parameters from the ECG that is severely contaminated by noise source. In this paper, we performed the extracting parameters from and recovering the ECG signal using wavelets transform that has recently been applying to various fields.

  • PDF

A Novel Method to Estimate Heart Rate from ECG

  • Leu, Jenq-Shiun;Lo, Pei-Chen
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.441-448
    • /
    • 2007
  • Heart rate variability (HRV) in electrocardiogram (ECG) is an important index for understanding the health status of heart and the autonomic nervous system. Most HRV analysis approaches are based on the proper heart rate (HR) data. Estimation of heart rate is thus a key process in the HRV study. In this paper, we report an innovative method to estimate the heart rate. This method is mainly based on the concept of periodicity transform (PT) and instantaneous period (IP) estimate. The method presented is accordingly called the "PT-IP method." It does not require ECG R-wave detection and thus possesses robust noise-immune capability. While the noise contamination, ECG time-varying morphology, and subjects' physiological variations make the R-wave detection a difficult task, this method can help us effectively estimate HR for medical research and clinical diagnosis. The results of estimating HR from empirical ECG data verify the efficacy and reliability of the proposed method.

Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad (침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를 처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘)

  • Lee, Won Kyu;Lee, Hong Ji;Yoon, Hee Nam;Chung, Gih Sung;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.87-94
    • /
    • 2014
  • Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascular system status. In this study, we developed a capacitive ECG measurement system that can be included within a cloth mattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However, it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high level of noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithm that can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated by determining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH Polysomnographic Database and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%, and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% for our capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providing useful ECG information, even under noisy signal conditions.

A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes

  • Yan, Long;Yoo, Hoi-Jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.300-308
    • /
    • 2010
  • This paper describes the development of a low-power electrocardiogram (ECG) touch sensor intended for the use with two dry metal electrodes. An equivalent ECG extraction circuit model encountered in a ground-free two-electrode configuration is investigated for an optimal sensor read-out circuit design criteria. From the equivalent circuit model, (1) maximum sensor resolution is derived based on the electrode's background thermal noise, which originates from high electrode-skin contact impedance, together with the input referred noise of instrumentation amplifier (IA), (2) 60 Hz electrostatic coupling from mains and motion artifact are also considered to determine minimum requirement of common mode rejection ratio (CMRR) and input impedance of IA. A dedicated ECG read-out front end incorporating chopping scheme is introduced to provide an input referred circuit noise of 1.3 ${\mu}V_{rms}$ over 0.5 Hz ~ 200 Hz, CMRR of IA > 100 dB, sensor resolution of 7 bits, and dissipating only 36 ${\mu}W$. Together with 8 bits synchronous successive approximation register (SAR) ADC, the sensor IC chip is implemented in 0.18 ${\mu}m$ CMOS technology and integrated on a 5 cm $\times$ 8 cm PCB with two copper patterned electrodes. With the help of proposed touch sensor, ECG signal containing QRS complex and P, T waves are successfully extracted by simply touching the electrodes with two thumbs.

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

Mobile measurement system of ECG signal in vehicle environment (차량운전자 심전도 신호의 QRS 검출 방법)

  • Park, Jae-Yong;Oh, Kwang-Seok;Lee, Choon-Young;Lee, Sang-Ryong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.895-896
    • /
    • 2006
  • This paper proposes a new method to measure the ECG signal from the driver. The ECG signal is often measured in the room. But it is mixed with many kinds of noise when we measure it during the vehicle moving. We classified noise occupied most many parts as the experimental among them. And we designed one suitable filter for each noise. It used ALE(Adaptive Line Enhancement) to remove the noise occurred to electromagnetic wave in vehicle. To remove the noise occurred to steering or vibration of vehicle, we used Wavelet transformation after ALE(preprocessing filter).

  • PDF

Design of real time FIR filter for removal of noise in ECG (ECG 신호의 잡음 제거를 위한 실시간 FIR 필터의 설계)

  • 황선철;이경중;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.690-693
    • /
    • 1987
  • Base-line wandering and 60Hz noise in ECG are removed by linear phase FIR filter. The important problem in FIR filtering is to reduce the number of impulse response coefficients. It can be reduced by symmetrical impulse response. The ripple is improved by window function .omega.(n). And the determination of filter accuracy is proposed by PRD(percent rms difference) algorithm.

  • PDF

Development of an Ambulatory Wearable System for Continuous Patient Monitoring (휴대용 심전도 모니터링 계측 시스템 개발에 관한 연구)

  • Park, Chan-Won;Jeon, Chan-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.920-923
    • /
    • 2003
  • An wearable electrocardiogram (ECG) monitoring system is a widely used non-invasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we have a portable ECG monitoring system with conductive fiber which was characterized by the small-size and the low power consumption. The system consists of conductive fibers, one-chip microcontroller, ECG preprocessing circuit, and monitoring software to be able to record and analyze in PC. ECG preprocessing circuit is made of pre-amplifier with gain of 10, band-pass filter with bandwidth of 0.5-120Hz and 2.5V offset circuit for A/D conversion. ECG signals obtained by sensor are included with corrupted noises such as a baseline wandering, 60 Hz power noise and interference noise by body movement. For cancellation corrupted noises in signals obtained by conductive fiber, we used the wavelet decomposition of wavelet transforms in MATLAB toolbox.

  • PDF